A method for T1 and T2 relaxation times validation and harmonization as a support to MRI mapping

被引:3
作者
Cicolari, Davide [1 ,2 ]
Lizio, Domenico [3 ]
Pedrotti, Patrizia [4 ]
Moioli, Monica Teresa [3 ]
Lascialfari, Alessandro [1 ,2 ]
Mariani, Manuel [1 ,2 ]
Torresin, Alberto [3 ,5 ]
机构
[1] Univ Pavia, Dept Phys, Via Bassi 6, I-27100 Pavia, Italy
[2] Ist Nazl Fis Nucl, Pavia Unit, Via Bassi 6, I-27100 Pavia, Italy
[3] ASST Grande Osped Metropolitano Niguarda, Dept Med Phys, Pzza Osped Maggiore 3, I-20162 Milan, Italy
[4] ASST Grande Osped Metropolitano Niguarda, Dept Cardiol, Pzza Osped Maggiore 3, I-20162 Milan, Italy
[5] Univ Milan, Dept Phys, Via Celoria 16, I-20133 Milan, Italy
关键词
Relaxation time maps; Data harmonization; Calibration; Accuracy; Precision; INVERSION-RECOVERY MOLLI; HIGH-RESOLUTION T-1; PARAMAGNETIC SOLUTIONS; HUMAN MYOCARDIUM; T1; ACCURACY; REPRODUCIBILITY; PRECISION; CALIBRATION; SEQUENCES;
D O I
10.1016/j.jmr.2021.107110
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a proof-of-concept study focusing on a method for the intra- and inter-center validation and harmonization of data obtained from MRI T-1 and T-2 maps. The method is based on a set of MnCl2 samples that provide in-scan ground-truth reference values regardless of the details of the MRI protocol. The relaxation times of MnCl2 aqueous solutions were first measured by means of an NMR laboratory relaxometer, as a function of concentration and temperature. The obtained T-1 and T-2 values, once renormalized at the scanner temperature, were used as reference values for the MRI mapping measurements of the MnCl2 relaxation times. By using different clinical MRI scanners and sequences, we found a good agreement for standard and turbo sequences (limits of agreement: 5% for IR, SE, IR-TSE; 10% for TSE), while an under-estimation and an over-estimation were found respectively for MOLLI and T-2-prep TrueFISP, as already reported in the literature. The linearity of the relaxation rates with the concentration predicted by the Solomon-Bloembergen-Morgan theory was observed for every dataset at all temperatures, except for T-2-prep TrueFISP maps results. Some preliminary results of an in vivo experiment are also presented. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Quantitative assessment of morphology, T1ρ, and T2 of shoulder cartilage using MRI
    Nardo, Lorenzo
    Carballido-Gamio, Julio
    Tang, Solomon
    Lai, Andrew
    Krug, Roland
    EUROPEAN RADIOLOGY, 2016, 26 (12) : 4656 - 4663
  • [2] Determining the longitudinal accuracy and reproducibility of T1 and T2 in a 3T MRI scanner
    Carr, Madeline E.
    Keenan, Kathryn E.
    Rai, Robba
    Metcalfe, Peter
    Walker, Amy
    Holloway, Lois
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (11): : 143 - 150
  • [3] A three-dimensional free-breathing sequence for simultaneous myocardial T1 and T2 mapping
    Guo, Rui
    Chen, Zhensen
    Herzka, Daniel A.
    Luo, Jianwen
    Ding, Haiyan
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1031 - 1043
  • [4] Consensus-based technical recommendations for clinical translation of renal T1 and T2 mapping MRI
    Dekkers, Ilona A.
    de Boer, Anneloes
    Sharma, Kaniska
    Cox, Eleanor F.
    Lamb, Hildo J.
    Buckley, David L.
    Bane, Octavia
    Morris, David M.
    Prasad, Pottumarthi, V
    Semple, Scott I. K.
    Gillis, Keith A.
    Hockings, Paul
    Buchanan, Charlotte
    Wolf, Marcos
    Laustsen, Christoffer
    Leiner, Tim
    Haddock, Bryan
    Hoogduin, Johannes M.
    Pullens, Pim
    Sourbron, Steven
    Francis, Susan
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (01) : 163 - 176
  • [5] Influence of Physical Activity on T1 and T2*Relaxation Times of Healthy Achilles Tendons at 3T
    Grosse, Ulrich
    Springer, Fabian
    Hein, Tobias
    Groezinger, Gerd
    Schabel, Christoph
    Martirosian, Petros
    Schick, Fritz
    Syha, Roland
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (01) : 193 - 201
  • [6] Arrhythmia insensitive rapid cardiac T1 mapping: comparison to modified look locker inversion recovery T1 mapping in mitral valve prolapse patients
    Cheung, Ernest
    Han, Hui-Chen
    Hornsey, Emma
    Churilov, Leonid
    Hong, Kyung Pyo
    Smith, Julie
    Kim, Daniel
    Farouque, Omar
    Teh, Andrew
    Lim, Han
    Lim, Ruth P.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (10) : 2017 - 2025
  • [7] Scanner-Independent MyoMapNet for Accelerated Cardiac MRI T1 Mapping Across Vendors and Field Strengths
    Amyar, Amine
    Fahmy, Ahmed. S. S.
    Guo, Rui
    Nakata, Kei
    Sai, Eiryu
    Rodriguez, Jennifer
    Cirillo, Julia
    Pareek, Karishma
    Kim, Jiwon
    Judd, Robert. M. M.
    Ruberg, Frederick. L. L.
    Weinsaft, Jonathan. W. W.
    Nezafat, Reza
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, : 179 - 189
  • [8] Accuracy, repeatability, and reproducibility of T1 and T2 relaxation times measurement by 3D magnetic resonance fingerprinting with different dictionary resolutions
    Krishna Pandu Wicaksono
    Yasutaka Fushimi
    Satoshi Nakajima
    Akihiko Sakata
    Sachi Okuchi
    Takuya Hinoda
    Sonoko Oshima
    Sayo Otani
    Hiroshi Tagawa
    Yuta Urushibata
    Yuji Nakamoto
    European Radiology, 2023, 33 : 2895 - 2904
  • [9] Repeatability of radiomic features in myocardial T1 and T2 mapping
    Manzke, Mathias
    Laqua, Fabian C.
    Boettcher, Benjamin
    Klemenz, Ann-Christin
    Weber, Marc-Andre
    Baessler, Bettina
    Meinel, Felix G.
    EUROPEAN RADIOLOGY, 2025, 35 (03) : 1570 - 1582
  • [10] Accuracy, repeatability, and reproducibility of T1 and T2 relaxation times measurement by 3D magnetic resonance fingerprinting with different dictionary resolutions
    Wicaksono, Krishna Pandu
    Fushimi, Yasutaka
    Nakajima, Satoshi
    Sakata, Akihiko
    Okuchi, Sachi
    Hinoda, Takuya
    Oshima, Sonoko
    Otani, Sayo
    Tagawa, Hiroshi
    Urushibata, Yuta
    Nakamoto, Yuji
    EUROPEAN RADIOLOGY, 2023, 33 (04) : 2895 - 2904