Effects of mobile phone exposure on biochemical parameters of cord blood: A preliminary study

被引:9
|
作者
Bektas, Hava [1 ]
Bektas, Mehmet Selcuk [2 ]
Dasdag, Suleyman [3 ]
机构
[1] Van Yuzuncu Yil Univ, Sch Med, Dept Biophys, Van, Turkey
[2] Lokman Hekim Hosp, Div Neonatol, Dept Pediat, Van, Turkey
[3] Istanbul Medeniyet Univ, Sch Med, Dept Biophys, TR-34700 Istanbul, Turkey
关键词
Mobile phone; radiofrequency radiation (RFR); cord blood; biochemical parameters; pregnant; RADIOFREQUENCY ELECTROMAGNETIC-FIELDS; FREQUENCY MAGNETIC-FIELDS; CARDIAC TROPONIN-T; OXIDATIVE STRESS; MYOCARDIAL INJURY; CREATINE-KINASE; ELECTRIC-FIELD; RADIATION; RATS; SERUM;
D O I
10.1080/15368378.2018.1499033
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The purpose of this study is to investigate foetal impact of radiofrequencies (RFs) emitted from mobile phones in postnatal cord blood. The study carried on 149 pregnant women divided into four groups such as nonusers of mobile phone (n: 37; control group), 2-15min/d (n: 39; group 1), 15-60min/d (n: 37; group 2) and participants using mobile phone for more than 60min/d (n: 36; group 3). Cord blood of the infants was taken in all groups for biochemical analyses immediately after birth. The results of the study showed that the biggest foetal impact was observed in the third study group which was pregnant exposed RFRs (RF radiation) more than 1h/d (1hour per day). AST (aspartat aminotransferaz), ALT (alanine aminotransferase), LDH (lactate dehydrogenase), CK (creatine kinase), CK-MB (creatine kinase-miyocardial band), CRP (c-reactive protein), PCT (procalcitonin), TnT (troponin T), uric acid and lactate levels of third group were found higher than the other groups (p<0.001). However, Mean platelet volume values of third group were found lower than the other groups (p<0.001). Finally, this is the first human study which was performed on pregnant and infants because there is no previous work in this area. However, the results of this study revealed that long-term RFR exposure of pregnant may result in some biochemical changes in the infants. Therefore, our suggestion to pregnant is to avoid from RFR exposure emitted from mobile phones at least during pregnancy.
引用
收藏
页码:184 / 191
页数:8
相关论文
共 50 条
  • [41] Mobile phone exposure influences some erythrocytes parameters in vitro. A novel source of preanalytical variability?
    Danese, Elisa
    Lippi, Giuseppe
    Brocco, Giorgio
    Montagnana, Martina
    Salvagno, Gian Luca
    DIAGNOSIS, 2016, 3 (02) : 75 - 79
  • [42] The effects of the duration of mobile phone use on heart rate variability parameters in healthy subjects
    Ekici, Berkay
    Tanindi, Asli
    Ekici, Gamze
    Diker, Erdem
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2016, 16 (11) : 833 - 838
  • [43] Thermal effects of mobile phone RF fields on children: A provocation study
    Lindholm, Harri
    Alanko, Tommi
    Rintamaki, Hannu
    Kannala, Sami
    Toivonen, Tommi
    Sistonen, Heli
    Tiikkaja, Maria
    Halonen, Janne
    Makinen, Tero
    Hietanen, Maila
    PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2011, 107 (03) : 399 - 403
  • [44] Exposure to mobile phone electromagnetic fields and subjective symptoms: A double-blind study
    Cinel, Caterina
    Russo, Riccardo
    Boldini, Angela
    Fox, Elaine
    PSYCHOSOMATIC MEDICINE, 2008, 70 (03): : 345 - 348
  • [45] Evidence for mobile phone radiation exposure effects on reproductive pattern of male rats: Role of ROS
    Kesari, Kavindra Kumar
    Behari, Jitendra
    ELECTROMAGNETIC BIOLOGY AND MEDICINE, 2012, 31 (03) : 213 - 222
  • [46] 4G mobile phone radiation alters some immunogenic and vascular gene expressions, and gross and microscopic and biochemical parameters in the chick embryo model
    Islam, Md. Sadequl
    Islam, Md. Mominul
    Rahman, Md. Moshiur
    Islam, Khaleda
    VETERINARY MEDICINE AND SCIENCE, 2023, 9 (06) : 2648 - 2659
  • [47] Effects of Internal Exposure to 56MnO2 Powder on Blood Parameters in Rats
    Fujimoto, Nariaki
    Baurzhan, Arailym
    Chaizhunusova, Nailya
    Amantayeva, Gaukhar
    Kairkhanova, Ynkar
    Shabdarbaeva, Dariya
    Zhunussov, Yersin
    Zhumadilov, Kassym
    Stepanenko, Valeriy
    Gnyrya, Vyacheslav
    Azhimkhanov, Almas
    Kolbayenkov, Alexander
    Hoshi, Masaharu
    EURASIAN JOURNAL OF MEDICINE, 2020, 52 (01) : 52 - 56
  • [48] The effects of short term cytokine exposure on cord blood stem cells
    Rice, AM
    Case, J
    Gaudry, L
    Vowels, MR
    CANCER RESEARCH THERAPY & CONTROL, 1998, 5 (02): : 121 - 132
  • [49] Lipid peroxidation and biochemical parameters in umbilical cord blood of well-adapted term newborns
    Macekova, Denisa
    Kovac, Gustav
    Hinst, Jaroslav
    Illek, Branislav
    Pereckova, Jana
    Baroskova, Zelmira
    Liska, Branislav
    BIOLOGIA, 2009, 64 (02) : 409 - 413
  • [50] Assessment of biochemical parameters after exposure to ultrasound waves; an in vivo study
    Salimi, Ali
    Ahmadi, Rahim
    Khezerloo, Jamil Kheirvari
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (13): : 6054 - 6058