Effects of mobile phone exposure on biochemical parameters of cord blood: A preliminary study

被引:9
|
作者
Bektas, Hava [1 ]
Bektas, Mehmet Selcuk [2 ]
Dasdag, Suleyman [3 ]
机构
[1] Van Yuzuncu Yil Univ, Sch Med, Dept Biophys, Van, Turkey
[2] Lokman Hekim Hosp, Div Neonatol, Dept Pediat, Van, Turkey
[3] Istanbul Medeniyet Univ, Sch Med, Dept Biophys, TR-34700 Istanbul, Turkey
关键词
Mobile phone; radiofrequency radiation (RFR); cord blood; biochemical parameters; pregnant; RADIOFREQUENCY ELECTROMAGNETIC-FIELDS; FREQUENCY MAGNETIC-FIELDS; CARDIAC TROPONIN-T; OXIDATIVE STRESS; MYOCARDIAL INJURY; CREATINE-KINASE; ELECTRIC-FIELD; RADIATION; RATS; SERUM;
D O I
10.1080/15368378.2018.1499033
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The purpose of this study is to investigate foetal impact of radiofrequencies (RFs) emitted from mobile phones in postnatal cord blood. The study carried on 149 pregnant women divided into four groups such as nonusers of mobile phone (n: 37; control group), 2-15min/d (n: 39; group 1), 15-60min/d (n: 37; group 2) and participants using mobile phone for more than 60min/d (n: 36; group 3). Cord blood of the infants was taken in all groups for biochemical analyses immediately after birth. The results of the study showed that the biggest foetal impact was observed in the third study group which was pregnant exposed RFRs (RF radiation) more than 1h/d (1hour per day). AST (aspartat aminotransferaz), ALT (alanine aminotransferase), LDH (lactate dehydrogenase), CK (creatine kinase), CK-MB (creatine kinase-miyocardial band), CRP (c-reactive protein), PCT (procalcitonin), TnT (troponin T), uric acid and lactate levels of third group were found higher than the other groups (p<0.001). However, Mean platelet volume values of third group were found lower than the other groups (p<0.001). Finally, this is the first human study which was performed on pregnant and infants because there is no previous work in this area. However, the results of this study revealed that long-term RFR exposure of pregnant may result in some biochemical changes in the infants. Therefore, our suggestion to pregnant is to avoid from RFR exposure emitted from mobile phones at least during pregnancy.
引用
收藏
页码:184 / 191
页数:8
相关论文
共 50 条
  • [31] Effects of electromagnetic radiation from 3G mobile phone on heart rate, blood pressure and ECG parameters in rats
    Colak, Cengiz
    Parlakpinar, Hakan
    Ermis, Necip
    Tagluk, Mehmet Emin
    Colak, Cemil
    Sarihan, Ediz
    Dilek, Omer Faruk
    Turan, Bahadir
    Bakir, Sevtap
    Acet, Ahmet
    TOXICOLOGY AND INDUSTRIAL HEALTH, 2012, 28 (07) : 629 - 638
  • [32] Blood Culture Testing via a Mobile App That Uses a Mobile Phone Camera: A Feasibility Study
    Lee, Guna
    Lee, Yura
    Chong, Yong Pil
    Jang, Seongsoo
    Kim, Mi Na
    Kim, Jeong Hoon
    Kim, Woo Sung
    Lee, Jae-Ho
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2016, 18 (10)
  • [33] Effects of Exposure to GSM Mobile Phone Base Station Signals on Salivary Cortisol, Alpha-Amylase, and Immunoglobulin A
    Augner, Christoph
    Hacker, Gerhard W.
    Oberfeld, Gerd
    Florian, Matthias
    Hitzl, Wolfgang
    Hutter, Joerg
    Pauser, Gernot
    BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2010, 23 (03) : 199 - 207
  • [34] Effects of thirty minute mobile phone irradiation on morphological and physiological parameters and gene expression in pregnant rats and their fetuses
    El-Sayed, Ashraf
    Badr, Hoda S.
    Yahia, Rania
    Salem, Salem M.
    Kandil, Asmaa M.
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (84): : 19670 - 19680
  • [35] Effects of Greek Honey and Propolis on Oxidative Stress and Biochemical Parameters in Regular Blood Donors
    Tsamesidis, Ioannis
    Egwu, Chinedu O.
    Samara, Diana
    Vogiatzi, Dimitra
    Lettas, Athanasios
    Lymperaki, Evgenia
    JOURNAL OF XENOBIOTICS, 2022, 12 (01) : 13 - 20
  • [36] Doctor-to-patient communication by 2.5G mobile phone; preliminary study
    Hyodo, K
    Chihara, K
    Yasumuro, Y
    Imura, M
    Manabe, Y
    Masuda, Y
    Naganawa, M
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 196 - 199
  • [37] Effects of Epiphyseal Proteins and Melatonin on Blood Biochemical Parameters of Fluoride-Intoxicated Rats
    Bharti, V. K.
    Srivastava, R. S.
    NEUROPHYSIOLOGY, 2011, 42 (04) : 258 - 264
  • [38] Effects of subchronic extremely low-frequency electromagnetic field exposure on biochemical parameters in rats
    Luo, Xue
    Ma, Lingjuan
    Gao, Peng
    Zhang, Yanwen
    TOXICOLOGY AND INDUSTRIAL HEALTH, 2017, 33 (04) : 365 - 372
  • [39] Effects of sodium fluoride exposure on some biochemical parameters in mice: Evaluation of the ameliorative effect of royal jelly applications on these parameters
    Kanbur, Murat
    Eraslan, Goekhan
    Silici, Sibel
    Karabacak, Muersel
    FOOD AND CHEMICAL TOXICOLOGY, 2009, 47 (06) : 1184 - 1189
  • [40] Nandrolone decanoate's effects on biochemical blood parameters in rat
    Ehsan, Mohammad Reza
    Tourchi, Seyed Majdodin Vahidi
    Mandavi, Ali