Similarities of Arterial Collagen Pressure-Diameter Relationship in Ovine Femoral Arteries and PLLA Vascular Grafts

被引:0
作者
Armentano, Ricardo L. [1 ]
Cymberknop, Leandro J. [2 ]
Suarez Bagnasco, Diego [3 ]
Montini Ballarin, Florencia [4 ]
Balay, Guillermo [3 ]
Negreira, Carlos A. [3 ]
Abraham, Gustavo A. [4 ]
机构
[1] Republ Univ, Northwest Reg Univ Ctr, Paysandu, Uruguay
[2] Natl Technol Univ, Buenos Aires Reg Fac, Buenos Aires, DF, Argentina
[3] Republ Univ, Fac Sci, Montevideo, Uruguay
[4] Mar Plata Univ, Fac Engn, INTEMA, Buenos Aires, DF, Argentina
来源
2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2014年
关键词
vascular grafts; PLLA; mechanical properties; pressure-diameter loop; femoral arteries; CONSCIOUS DOGS; MECHANICS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: In-vivo implanted vascular grafts fail due to the mechanical mismatch between the native vessel and the implant. The biomechanical characterization of native vessels provides valuable information towards the development of synthetic grafts. Materials and Methods: Five samples of electrospun nanofibrous poly(L-lactic acid)(PLLA) tubular structures were subjected to physiological pulsating pressure using an experimental setup. Four ovine femoral arteries were also tested in the experimental setup under the same conditions. Instantaneous diameter and pressure signals were obtained using gold standard techniques, in order to estimate the dynamic pressure-strain elastic modulus (E-P epsilon) of both native vessels and grafts. Results: Synthetic grafts showed a significant increase of E-P epsilon (10.57 +/- 0.97 to 17.63 +/- 2.61 10(6) dyn/cm(2)) when pressure was increased from a range of 50-90 mmHg (elastin-response range) to a range of 100-130 mmHg (collagen-response range). Furthermore, femoral arteries also exhibited a significant increase of E-P epsilon (1.66 +/- 0.30 to 15.76 +/- 4.78 10(6) dyn/cm(2)) with the same pressure variation, showing that both native vessels and synthetic grafts have a similar behavior in the collagen-acting range. Conclusion: The mechanical behavior of PLLA vascular grafts was characterized In vitro. However, the procedure can be easily extrapolated to In vivo experiences in conscious and chronically instrumented animals.
引用
收藏
页码:2302 / 2305
页数:4
相关论文
共 14 条
[1]  
ARMENTANO RL, 1994, MED PROG TECHNOL, V20, P91
[2]   ARTERIAL-WALL MECHANICS IN CONSCIOUS DOGS - ASSESSMENT OF VISCOUS, INERTIAL, AND ELASTIC-MODULI TO CHARACTERIZE AORTIC-WALL BEHAVIOR [J].
ARMENTANO, RL ;
BARRA, JG ;
LEVENSON, J ;
SIMON, A ;
PICHEL, RH .
CIRCULATION RESEARCH, 1995, 76 (03) :468-478
[3]  
BALAY G, 2010, C P IEEE ENG MED BIO, P2521
[4]   ASSESSMENT OF SMOOTH-MUSCLE CONTRIBUTION TO DESCENDING THORACIC AORTIC ELASTIC MECHANICS IN CONSCIOUS DOGS [J].
BARRA, JG ;
ARMENTANO, RL ;
LEVENSON, J ;
FISCHER, EIC ;
PICHEL, RH ;
SIMON, A .
CIRCULATION RESEARCH, 1993, 73 (06) :1040-1050
[5]   Set up of a cardiovascular simulator: application to the evaluation of the dynamical behavior of atheroma plaques in human arteries [J].
Brum, J. ;
Bia, D. ;
Benech, N. ;
Balay, G. ;
Armentano, R. ;
Negreira, C. .
INTERNATIONAL CONGRESS ON ULTRASONICS, PROCEEDINGS, 2010, 3 (01) :1095-1101
[6]   Identification of arterial wall dynamics in conscious dogs [J].
Gamero, LG ;
Armentano, RL ;
Barra, JG ;
Simon, A ;
Levenson, J .
EXPERIMENTAL PHYSIOLOGY, 2001, 86 (04) :519-528
[7]   Development of a composite vascular scaffolding system that withstands physiological vascular conditions [J].
Lee, Sang Jin ;
Liu, Jie ;
Oh, Se Heang ;
Soker, Shay ;
Atala, Anthony ;
Yoo, James J. .
BIOMATERIALS, 2008, 29 (19) :2891-2898
[8]  
Nerem RM, 2003, BIORHEOLOGY, V40, P281
[9]   Design and Fabrication of a Mechanically Matched Vascular Graft [J].
Rachev, Alexander ;
Felden, Luc ;
Ku, David N. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (09)
[10]  
Sonoda H, 2001, J BIOMED MATER RES, V55, P266, DOI 10.1002/1097-4636(20010605)55:3<266::AID-JBM1014>3.0.CO