Evaluation of effect of analytical imprecision in maternal serum screening for Down's syndrome

被引:20
作者
Benn, PA [1 ]
Collins, R [1 ]
机构
[1] Univ Connecticut, Ctr Hlth, Dept Pediat, Div Human Genet, Farmington, CT 06032 USA
关键词
D O I
10.1258/0004563011900254
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Formulae to evaluate the effect of inter-assay analytical imprecision (expressed as the coefficient of variation) in maternal serum screening for Down's syndrome have been developed. Experimentally determined imprecision in Down's syndrome risk (based on maternal serum x-fetoprotein. unconjugated oestriol and human chorionic gonadotrophin) was found to be consistent with predicted values. Imprecision in the measurement of analytes becomes amplified when risk is calculated using the values of these analytes. A large separation between the means and small standard deviations for normal and affected pregnancies are the characteristics of the tests most useful in screening? but these attributes also result in the most imprecision in risk. In addition, the relative imprecision associated with Down's syndrome risk is not the same for all women screened. Combining tests for multivariate analyses results in a complex compounding of the errors. The need for strict quality control and test reproducibility is emphasized. The effect of analytical imprecision should be of particular concern to laboratories that provide screening for women of advanced maternal age.
引用
收藏
页码:28 / 36
页数:9
相关论文
共 27 条
[1]   Risk of Down syndrome and any clinically significant chromosome defect in pregnancies with abnormal triple-screen and normal targeted ultrasonographic results [J].
BahadoSingh, RO ;
Tan, A ;
Deren, O ;
Hunter, D ;
Copel, J ;
Mahoney, MJ .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1996, 175 (04) :824-829
[2]  
Baird D. C., 1962, EXPT INTRO MEASUREME
[3]  
Beazoglou T, 1998, PRENATAL DIAG, V18, P1241, DOI 10.1002/(SICI)1097-0223(199812)18:12<1241::AID-PD440>3.0.CO
[4]  
2-M
[5]   Down syndrome and neural tube defect screening: The value of using gestational age by ultrasonography [J].
Benn, PA ;
Borgida, A ;
Horne, D ;
Briganti, S ;
Collins, R ;
Rodis, JF .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1997, 176 (05) :1056-1061
[6]  
BENN PA, 1995, AM J OBSTET GYNECOL, V173, P495
[7]  
*COLL AM PATH, 1998, FBR CAP MAT SCREEN S
[8]   ESTIMATING A WOMANS RISK OF HAVING A PREGNANCY ASSOCIATED WITH DOWNS-SYNDROME USING HER AGE AND SERUM ALPHA-FETOPROTEIN LEVEL [J].
CUCKLE, HS ;
WALD, NJ ;
THOMPSON, SG .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1987, 94 (05) :387-402
[9]  
Diem K, 1971, SCI TABLES
[10]   Screening of maternal serum for fetal Down's syndrome in the first trimester [J].
Haddow, JE ;
Palomaki, GE ;
Knight, GJ ;
Williams, J ;
Miller, WA ;
Johnson, A .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (14) :955-961