Computer-aided detection of small pulmonary nodules in multidetector spiral computed tomography (MSCT) in children

被引:5
|
作者
Honnef, D. [1 ]
Behrendt, F. F. [1 ]
Bakai, A.
Hohl, C. [1 ]
Mahnken, A. H. [1 ]
Mertens, R. [1 ]
Stanzel, S. [1 ]
Guenther, R. W. [1 ]
Das, M. [1 ]
机构
[1] Univ Klinikum RWTH Aachen, D-52057 Aachen, Germany
关键词
thorax; metastases; CTspiral; computer-aided diagnosis; pediatric; nodule;
D O I
10.1055/s-2008-1027285
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Retrospective evaluation of computer-aided detection software (CAD) for automated detection (LungCAD, Siemens Medical solutions, Forchheim, Germany) and volumetry (Lung-CARE) of pulmonary nodules in dose-reduced pediatric MDCT. Materials and Methods: 30 scans of 24 children (10.4 +/- 5.9 years, 13 girls, 11 boys, 39.7 +/- 29.3 kg body weight) were performed on a 16-MDCT for tumor staging (n=18), inflammation (n=9), other indications (n=3). Tube voltage 120 kVp and effective mAs were adapted to body weight. Slice thickness 2 mm, increment 1 mm. A pediatric radiologist (U1), a CAD expert (U2) and an inexperienced radiologist (U3) independently analyzed the lung window images without and with the CAD as a second reader. In a consensus decision U1 and U2 were the reference standard. Results: Five examinations had to be excluded from the study due to other underlying lung disease. A total of 24 pulmonary nodules were found in all data sets with a minimal diameter of 0.35 mm to 3.81 mm (mean 1.7 +/- 0.85 mm). The sensitivities were as follows: U1 95.8 % and 100 % with CAD; U2 91.7% U3 66.7%. U2 and U3 did not detect further nodules with CAD. The sensitivity of CAD alone was 41.7% with 0.32 false-positive findings per examination. Interobserver agreement between U1/U2 regarding nodule detection with CAD was good (k = 0.6500) and without CAD very good (k = 0.8727). For the rest (U1/U3; U2/U3 with and without CAD), it was weak (k=0.0667-0.1884). Depending on the measured value (axial measurement, volume), there is a significant correlation (p=0.0026-0.0432) between nodule size and CAD detection. Undetected pulmonary nodules (mean 1.35 mm; range 0.35 - 2.61 mm) were smaller than the detected ones (mean 2.19 mm; range 1.35 - 3.81 mm). No significant correlation was found between CAD findings and patient age (p=0.9263) and body weight (p=0.9271) as well as nodule location (subpleural, intraparenchymal; p = 1.0) and noise/SNR. Conclusion: In our study with 2 mm slice thickness and very small lesion sizes, the analyzed CAD algorithm for detection and volumetry of pulmonary nodules has limited application in pediatric dose-reduced 16-MDCTs. Determination of lesion size is possible even in the case of false-negatives.
引用
收藏
页码:540 / 546
页数:7
相关论文
共 50 条
  • [31] COMPUTER-AIDED DETECTION OF PULMONARY NODULES USING GENETIC PROGRAMMING
    Choi, Wook-Jin
    Choi, Tae-Sun
    2010 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, 2010, : 4353 - 4356
  • [32] Clinical experience with a computer-aided diagnosis system for automatic detection of pulmonary nodules at spiral CT of the chest
    Wormanns, D
    Fiebich, M
    Saidi, M
    Diederich, S
    Heindel, W
    MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES, 2001, 4319 : 144 - 149
  • [33] Automatic detection of pulmonary nodules at spiral CT - first clinical experience with a computer-aided diagnosis system
    Wormanns, D
    Fiebich, M
    Wietholt, C
    Diederich, S
    Heindel, W
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 129 - 135
  • [34] Model-based detection of lung nodules in computed tomography exams -: Thoracic computer-aided diagnosis
    McCulloch, CC
    Kaucic, RA
    Mendonça, PRS
    Walter, DJ
    Avila, RS
    ACADEMIC RADIOLOGY, 2004, 11 (03) : 258 - 266
  • [35] Evaluation of Classifiers for Computer-aided Detection in Computed Tomography Colonography
    Song, Bowen
    Zhu, Hongbin
    Zhu, Wei
    Liang, Zhengrong
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3850 - 3854
  • [36] A new dataset of computed-tomography angiography images for computer-aided detection of pulmonary embolism
    Mojtaba Masoudi
    Hamid-Reza Pourreza
    Mahdi Saadatmand-Tarzjan
    Noushin Eftekhari
    Fateme Shafiee Zargar
    Masoud Pezeshki Rad
    Scientific Data, 5
  • [37] A new dataset of computed-tomography angiography images for computer-aided detection of pulmonary embolism
    Masoudi, Mojtaba
    Pourreza, Hamid-Reza
    Saadatmand-Tarzjan, Mahdi
    Eftekhari, Noushin
    Zargar, Fateme Shafiee
    Rad, Masoud Pezeshki
    SCIENTIFIC DATA, 2018, 5
  • [38] Computer-aided detection of pulmonary nodules:: influence of nodule characteristics on detection performance
    Marten, K
    Engelke, C
    Seyfarth, T
    Grillhösl, A
    Obenauer, S
    Rummeny, EJ
    CLINICAL RADIOLOGY, 2005, 60 (02) : 196 - 206
  • [39] Computer-aided detection of pulmonary nodules in low-dose CT
    Delogu, P.
    Fantacci, M. E.
    Gori, I.
    Martinez, A. Preite
    Retico, A.
    COMPUTATIONAL MODELLING OF OBJECTS REPRESENTED IN IMAGES: FUNDAMENTALS, METHODS AND APPLICATIONS, 2007, : 165 - 167
  • [40] Observer training for computer-aided detection of pulmonary nodules in chest radiography
    De Boo, Diederick W.
    van Hoorn, Francois
    van Schuppen, Joost
    Schijf, Laura
    Scheerder, Maeke J.
    Freling, Nicole J.
    Mets, Onno
    Weber, Michael
    Schaefer-Prokop, Cornelia M.
    EUROPEAN RADIOLOGY, 2012, 22 (08) : 1659 - 1664