Computer-aided detection of small pulmonary nodules in multidetector spiral computed tomography (MSCT) in children

被引:5
|
作者
Honnef, D. [1 ]
Behrendt, F. F. [1 ]
Bakai, A.
Hohl, C. [1 ]
Mahnken, A. H. [1 ]
Mertens, R. [1 ]
Stanzel, S. [1 ]
Guenther, R. W. [1 ]
Das, M. [1 ]
机构
[1] Univ Klinikum RWTH Aachen, D-52057 Aachen, Germany
关键词
thorax; metastases; CTspiral; computer-aided diagnosis; pediatric; nodule;
D O I
10.1055/s-2008-1027285
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Retrospective evaluation of computer-aided detection software (CAD) for automated detection (LungCAD, Siemens Medical solutions, Forchheim, Germany) and volumetry (Lung-CARE) of pulmonary nodules in dose-reduced pediatric MDCT. Materials and Methods: 30 scans of 24 children (10.4 +/- 5.9 years, 13 girls, 11 boys, 39.7 +/- 29.3 kg body weight) were performed on a 16-MDCT for tumor staging (n=18), inflammation (n=9), other indications (n=3). Tube voltage 120 kVp and effective mAs were adapted to body weight. Slice thickness 2 mm, increment 1 mm. A pediatric radiologist (U1), a CAD expert (U2) and an inexperienced radiologist (U3) independently analyzed the lung window images without and with the CAD as a second reader. In a consensus decision U1 and U2 were the reference standard. Results: Five examinations had to be excluded from the study due to other underlying lung disease. A total of 24 pulmonary nodules were found in all data sets with a minimal diameter of 0.35 mm to 3.81 mm (mean 1.7 +/- 0.85 mm). The sensitivities were as follows: U1 95.8 % and 100 % with CAD; U2 91.7% U3 66.7%. U2 and U3 did not detect further nodules with CAD. The sensitivity of CAD alone was 41.7% with 0.32 false-positive findings per examination. Interobserver agreement between U1/U2 regarding nodule detection with CAD was good (k = 0.6500) and without CAD very good (k = 0.8727). For the rest (U1/U3; U2/U3 with and without CAD), it was weak (k=0.0667-0.1884). Depending on the measured value (axial measurement, volume), there is a significant correlation (p=0.0026-0.0432) between nodule size and CAD detection. Undetected pulmonary nodules (mean 1.35 mm; range 0.35 - 2.61 mm) were smaller than the detected ones (mean 2.19 mm; range 1.35 - 3.81 mm). No significant correlation was found between CAD findings and patient age (p=0.9263) and body weight (p=0.9271) as well as nodule location (subpleural, intraparenchymal; p = 1.0) and noise/SNR. Conclusion: In our study with 2 mm slice thickness and very small lesion sizes, the analyzed CAD algorithm for detection and volumetry of pulmonary nodules has limited application in pediatric dose-reduced 16-MDCTs. Determination of lesion size is possible even in the case of false-negatives.
引用
收藏
页码:540 / 546
页数:7
相关论文
共 50 条
  • [1] Pulmonary embolism: Computer-aided detection at multidetector row spiral computed tomography
    Schoepf, U. Joseph
    Schneider, Alex C.
    Das, Marco
    Wood, Susan A.
    Cheema, Jugesh L.
    Costello, Philip
    JOURNAL OF THORACIC IMAGING, 2007, 22 (04) : 319 - 323
  • [2] Computer-Aided Detection of Pulmonary Nodules in Computed Tomography Using ClearReadCT
    Wagner, Anne-Kathrin
    Hapich, Arno
    Psychogios, Marios Nikos
    Teichgraeber, Ulf
    Malich, Ansgar
    Papageorgiou, Ismini
    JOURNAL OF MEDICAL SYSTEMS, 2019, 43 (03)
  • [3] Computer-Aided Detection of Pulmonary Nodules in Computed Tomography Using ClearReadCT
    Anne-Kathrin Wagner
    Arno Hapich
    Marios Nikos Psychogios
    Ulf Teichgräber
    Ansgar Malich
    Ismini Papageorgiou
    Journal of Medical Systems, 2019, 43
  • [4] Robust Computer-Aided Detection of Pulmonary Nodules from Chest Computed Tomography
    Abduh, Zaid
    Wahed, Manal Abdel
    Kadah, Yasser M.
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (03) : 693 - 699
  • [5] Evaluation of a method of computer-aided detection (CAD) of pulmonary nodules at computed tomography
    Foti, G.
    Faccioli, N.
    D'Onofrio, M.
    Contro, A.
    Milazzo, T.
    Mucelli, R. Pozzi
    RADIOLOGIA MEDICA, 2010, 115 (06): : 950 - 961
  • [6] Computer-aided detection of pulmonary nodules in computed tomography: Analysis and review of the literature
    Saba, Luca
    Caddeo, Giancarlo
    Mallarini, Giorgio
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (04) : 611 - 619
  • [7] Computer-Aided Detection of Pulmonary Nodules in Computed Tomography Images: Effect on Observer Performance
    Liu, JiaBao
    Wang, Yu
    Zhang, Fa
    Ren, Fei
    Liu, LiHeng
    He, Wen
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (06) : 1205 - 1211
  • [8] Computer-aided detection of solid lung nodules in lossy compressed multidetector computed tomography chest exams
    Raffy, Philippe
    Gaudeau, Yann
    Miller, Dave P.
    Moureaux, Jean-Marie
    Castellino, Ronald A.
    ACADEMIC RADIOLOGY, 2006, 13 (10) : 1194 - 1203
  • [9] Computer-aided detection for pulmonary nodules
    Koroglu, M
    Ernst, RD
    Oto, A
    Hardie, RC
    Gurcan, MN
    Allen, BH
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 85 - 85
  • [10] Computer-aided diagnosis of small pulmonary nodules
    Reeves, AP
    Kostis, WJ
    SEMINARS IN ULTRASOUND CT AND MRI, 2000, 21 (02) : 116 - 128