Muscle fatigue of the elbow flexor muscles during two intermittent exercise protocols with equal mean muscle loading

被引:23
作者
Seghers, J [1 ]
Spaepen, A [1 ]
机构
[1] Katholieke Univ Leuven, Dept Kinesiol, Lab Ergon & Occupat Biomech, B-3001 Louvain, Belgium
关键词
electromyography; muscle fatigue; intermittent exercise; elbow flexors;
D O I
10.1016/j.clinbiomech.2003.08.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Whether different muscle-loading patterns with the same mean load have a similar influence on the resultant muscle fatigue is still unknown. This study investigated the influence of two intermittent exercise protocols, with equal mean muscle loading, on the mechanical and myoelectrical signs of fatigue in the elbow flexor muscles. Design. Ten subjects performed two 20-min long intermittent isometric elbow flexion tasks. The exercise period load for the low force intermittent test was 25% of the maximum voluntary contraction, with a work-cycle time of 20 s and a duty cycle of 0.5. The high force intermittent exercise protocol had an exercise period load of 50% maximum voluntary contraction, a cycle time of 20 s and a duty cycle of 0.25. Methods. Muscle fatigue was quantified both by measuring the maximal voluntary contraction torque before and after the intermittent exercises, and also by the temporal changes observed in the electromyography signal. Results. Both muscle-loading patterns induced a 15% decrease in maximum voluntary contraction. However, the electromyographic spectral changes during the intermittent static contractions varied between the two protocols. Conclusions. Variation in muscle load without loss in productivity can affect the physiological responses. The results also showed that different methods to assess muscle fatigue sometimes provide different information on the resultant fatigue.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 18 条
[1]   MUSCLES ACROSS THE ELBOW JOINT - A BIOMECHANICAL ANALYSIS [J].
AN, KN ;
HUI, FC ;
MORREY, BF ;
LINSCHEID, RL ;
CHAO, EY .
JOURNAL OF BIOMECHANICS, 1981, 14 (10) :659-+
[2]  
BASMAJIAN JV, 1985, MUSCLES ALIVE
[3]  
Bigland-Ritchie B., 1986, ACTA PHYSL SCAND S, V556, P137
[4]   CHANGES IN MUSCLE CONTRACTILE PROPERTIES AND NEURAL CONTROL DURING HUMAN MUSCULAR FATIGUE [J].
BIGLANDRITCHIE, B ;
WOODS, JJ .
MUSCLE & NERVE, 1984, 7 (09) :691-699
[5]   ACCEPTABILITY OF INTERMITTENT HANDGRIP CONTRACTIONS BASED ON PHYSIOLOGICAL-RESPONSE [J].
BYSTROM, S ;
FRANSSONHALL, C .
HUMAN FACTORS, 1994, 36 (01) :158-171
[6]   The use of surface electromyography in biomechanics [J].
De Luca, CJ .
JOURNAL OF APPLIED BIOMECHANICS, 1997, 13 (02) :135-163
[7]   The effect of age and gender on the relative fatigability of the human adductor pollicis muscle [J].
Ditor, DS ;
Hicks, AL .
CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 2000, 78 (10) :781-790
[8]   Development of recommendations for SEMG sensors and sensor placement procedures [J].
Hermens, HJ ;
Freriks, B ;
Disselhorst-Klug, C ;
Rau, G .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2000, 10 (05) :361-374
[9]   Electromyographical indication of muscular fatigue in occupational field studies [J].
Luttmann, A ;
Jäger, M ;
Laurig, W .
INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2000, 25 (06) :645-660
[10]   THE INFLUENCE OF EXERCISE/REST SCHEDULE ON THE PHYSIOLOGICAL AND PSYCHOPHYSICAL RESPONSE TO ISOMETRIC SHOULDER-NECK EXERCISE [J].
MATHIASSEN, SE .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1993, 67 (06) :528-539