Behavior of Concrete-Filled FRP Tubes under Cyclic Axial Compression

被引:86
作者
Zhang, B. [1 ]
Yu, T. [2 ]
Teng, J. G. [3 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Hong Kong, Peoples R China
[2] Univ Wollongong, Sch Civil Min & Environm Engn, Fac Engn & Informat Sci, Wollongong, NSW 2522, Australia
[3] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Struct Engn, Hong Kong, Peoples R China
基金
澳大利亚研究理事会;
关键词
Fiber-reinforced polymer (FRP); Confinement; Concrete; Filament-wound tubes; Cyclic loading; High-strength concrete; Stress-strain behavior; STRESS-STRAIN MODEL; REINFORCED POLYMER TUBES; HIGH-STRENGTH CONCRETE; CONFINED CONCRETE; COLUMNS; PERFORMANCE; PRISMS;
D O I
10.1061/(ASCE)CC.1943-5614.0000523
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled fiber-reinforced polymer (FRP) tubes (CFFTs) are an attractive form of hybrid compression members incorporating FRP. CFFTs have several advantages over traditional column forms, including their excellent corrosion resistance and ductility. Much research has been conducted on CFFTs over recent years, but no systematic experimental study has been concerned with the cyclic axial compressive behavior of CFFTs with a filament-wound FRP tube; such studies are needed for the development of a cyclic stress-strain model for the concrete in CFFTs. This paper therefore presents an experimental study on the behavior of circular CFFTs under cyclic axial compression. The experimental program included the strength of concrete as a key variable so that it also provides a much needed supplement to the very limited existing research on the cyclic compressive behavior of FRP-confined high-strength concrete (HSC). The test results are compared with a monotonic stress-strain model and a cyclic stress-strain model for FRP-confined concrete, both of which have been based on test databases that are limited to concrete confined with an FRP wrap and include only a small number of tests for HSC. The test results show that the cyclic axial stress-strain behavior of concrete in CFFTs is generally similar to that of concrete confined by an FRP wrap. The test results also show that the monotonic stress-strain model perform reasonably well for HSC in CFFTs, but revisions to the cyclic stress-strain model are needed before it can provide accurate predictions for HSC in cyclically loaded CFFTs. (C) 2014 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 28 条
[1]   Cyclic and monotonic behavior of FRP confined concrete rectangular prisms with different aspect ratios [J].
Abbasnia, R. ;
Hosseinpour, F. ;
Rostamian, M. ;
Ziaadiny, H. .
CONSTRUCTION AND BUILDING MATERIALS, 2013, 40 :118-125
[2]   Effect of confinement level, aspect ratio and concrete strength on the cyclic stress-strain behavior of FRP-confined concrete prisms [J].
Abbasnia, R. ;
Ahmadi, R. ;
Ziaadiny, H. .
COMPOSITES PART B-ENGINEERING, 2012, 43 (02) :825-831
[3]   Behavior of concrete prisms confined with FRP composites under axial cyclic compression [J].
Abbasnia, R. ;
Ziaadiny, H. .
ENGINEERING STRUCTURES, 2010, 32 (03) :648-655
[4]  
Ahmad I., 2005, FIBER REINFORCED POL, VVII, P1085
[5]  
ASTM, 2008, STAND TEST METH APP
[6]   Cyclic Compressive Behavior of Concrete Confined with Large Rupture Strain FRP Composites [J].
Bai, Yu-Lei ;
Dai, Jian-Guo ;
Teng, J. G. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (01)
[7]   Shear response of concrete-filled FRP composite cylindrical shells [J].
Burgueño, R ;
Bhide, KM .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2006, 132 (06) :949-960
[8]  
Code of China, 2005, GBT53502005 COD CHIN
[9]   Experimental Study of Normal- and High-Strength Concrete Confined with Fiber-Reinforced Polymers [J].
Cui, C. ;
Sheikh, S. A. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (05) :553-561
[10]  
Fam AZ, 2001, ACI STRUCT J, V98, P451