Thermo-hydraulic coupled analysis of meshed district heating networks based on improved breadth first search method

被引:18
|
作者
Wang, Yaran [1 ,2 ]
Shi, Kaiyu [1 ,2 ]
Zheng, Xuejing [1 ,2 ]
You, Shijun [1 ,2 ]
Zhang, Huan [1 ,2 ]
Zhu, Chengzhi [3 ]
Li, Liang [3 ]
Wei, Shen [4 ]
Ding, Chao [1 ]
Wang, Na [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300350, Peoples R China
[2] Tianjin Key Lab Biomass Wastes Utilizat, Tianjin 300350, Peoples R China
[3] Shijiazhuang Huadian Heating Grp Co Ltd, Shijiazhuang 050041, Hebei, Peoples R China
[4] Univ Coll London UCL, Bartlett Sch Construct & Project Management, 1-19 Torrington Pl, London WC1E 7HB, England
基金
国家重点研发计划;
关键词
Meshed district heating network; Topology sorting; Improved breadth first search method; Thermo-hydraulic coupled model; Hydraulic computation frequency; Thermal dynamics; HYDRAULIC PERFORMANCE; OPTIMAL OPERATION; THERMAL INERTIA; PIPE MODEL; SYSTEM; OPTIMIZATION; SIMULATION; POWER; INTEGRATION; DYNAMICS;
D O I
10.1016/j.energy.2020.117950
中图分类号
O414.1 [热力学];
学科分类号
摘要
Efficient numerical simulation of thermo-hydraulic coupled conditions is critical for analysis and control of DH network. However, for most of meshed DH network, the flow directions of its pipelines may change, which will lead to difficulties in effective numerical calculation of the thermo-hydraulic conditions. This paper established an efficient thermo-hydraulic coupled calculation method, which utilizes the topology sorting algorithm to obtain the calculation sequence of all pipelines during numerical thermal transient calculation, according to the flow directions and flow rates of all pipelines. The flow directions and flow rates are solved by hydraulic condition calculation at each time step. The proposed method is applied to a real meshed DH network for thermal dynamic simulation. Independence analysis of hydraulic computation frequency is conducted, and convergences of the simulated temperature variations are observed when hydraulic computation frequency gets larger. Thermal dynamics of the meshed DH network are analyzed with 10-min hydraulic computation interval. Results show that the temperature decay and time delay can be up to 2.7 degrees C and 210 min for the simulated network. Thermal dynamic characteristics of supply temperature waves are various considering the distance from heat source, fluctuations of outdoor temperature and the variations of substation flow rate. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 3 条
  • [1] Thermo-hydraulic coupled simulation and analysis of a real large-scale complex district heating network in Tianjin
    Zheng, Xuejing
    Sun, Qihang
    Wang, Yaran
    Zheng, Lijun
    Gao, Xinyong
    You, Shijun
    Zhang, Huan
    Shi, Kaiyu
    ENERGY, 2021, 236
  • [2] Dynamic equation-based thermo-hydraulic pipe model for district heating and cooling systems
    van der Heijde, B.
    Fuchs, M.
    Tugores, C. Ribas
    Schweiger, G.
    Sartor, K.
    Basciotti, D.
    Mueller, D.
    Nytsch-Geusen, C.
    Wetter, M.
    Helsen, L.
    ENERGY CONVERSION AND MANAGEMENT, 2017, 151 : 158 - 169
  • [3] Passivity-Based Stability Analysis of Hydraulic Equilibria in 4th Generation District Heating Networks
    Strehle, Felix
    Vieth, Jonathan
    Pfeifer, Martin
    Hohmann, Soeren
    IFAC PAPERSONLINE, 2021, 54 (19): : 261 - 266