Compact soft x-ray source using Thomson scattering

被引:23
作者
Kashiwagi, S
Kuroda, R
Oshima, T
Nagasawa, F
Kobuki, T
Ueyama, D
Hama, Y
Washio, M
Ushida, K
Hayano, H
Urakawa, J
机构
[1] Waseda Univ, Adv Res Inst Sci & Engn, Shinjuku Ku, Tokyo 1698555, Japan
[2] RIKEN, Inst Phys & Chem Res, Wako, Saitama 3510198, Japan
[3] KEK, High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
关键词
D O I
10.1063/1.2148619
中图分类号
O59 [应用物理学];
学科分类号
摘要
A compact soft x-ray source using Thomson scattering, enabled by the combination of a picosecond laser and an electron rf gun, was developed aiming at biological studies such as those using an x-ray microscope. The x-ray source included both a photoinjector system and a picosecond laser system with a tabletop size of 2x2 m(2). An infrared laser beam (lambda(0)=1047 nm) was obtained from an all-solid-state mode-locked Nd:YLF laser system and injected into the photocathode of an accelerator system. A 4.2 MeV electron beam was generated from a laser-driven photocathode rf gun system. The residual laser beam was amplified up to about 4.2 mJ/pulse using a flash-lamp-pumped laser amplifier. Upon collision of the electron beam with the amplified laser beam, 300 eV soft x rays were generated by Thomson backscattering. The stable interaction between the two beams was achieved using the same seed laser pulse for irradiating the photocathode and the scattering process with laser photons. (c) 2005 American Institute of Physics.
引用
收藏
页数:6
相关论文
共 25 条
  • [1] Experimental characterization of an ultrafast Thomson scattering x-ray source with three-dimensional time and frequency-domain analysis
    Brown, WJ
    Anderson, SG
    Barty, CPJ
    Betts, SM
    Booth, R
    Crane, JK
    Cross, RR
    Fittinghoff, DN
    Gibson, DJ
    Hartemann, FV
    Hartouni, EP
    Kuba, J
    Le Sage, GP
    Slaughter, DR
    Tremaine, AM
    Wootton, AJ
    Springer, PT
    Rosenzweig, JB
    [J]. PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2004, 7 (06): : 23 - 34
  • [2] ENSO A, 2003, P SOC PHOTO-OPT INS, V5063, P269
  • [3] THE SOFT-X-RAY QUANTUM DETECTION EFFICIENCY OF MICROCHANNEL PLATES
    FRASER, GW
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 195 (03): : 523 - 538
  • [4] Optimization of the design for the LCLS undulator line
    Gluskin, E
    Vinokurov, NA
    Decker, G
    Dejus, RJ
    Emma, P
    Ilinski, P
    Moog, ER
    Nuhn, HD
    Vasserman, IB
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 475 (1-3) : 323 - 327
  • [5] Backscattering of an intense laser beam by an electron
    He, F
    Lau, YY
    Umstadter, DP
    Kowalczyk, R
    [J]. PHYSICAL REVIEW LETTERS, 2003, 90 (05) : 4
  • [6] Henke B. L., 1982, Atomic Data and Nuclear Data Tables, V27, P1, DOI 10.1016/0092-640X(82)90002-X
  • [7] Kashiwagi S, 2001, INT J APPL ELECTROM, V14, P157
  • [8] Observation of high-intensity X-rays in inverse Compton scattering experiment
    Kashiwagi, S
    Washio, M
    Kobuki, T
    Kuroda, R
    Ben-Zvi, I
    Pogorelsky, I
    Kusche, K
    Skaritka, J
    Yakimenko, V
    Wang, XJ
    Hirose, T
    Dobashi, K
    Muto, T
    Urakawa, J
    Omori, T
    Okugi, T
    Tsunemi, A
    Liu, Y
    He, P
    Cline, D
    Segalov, Z
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 455 (01) : 36 - 40
  • [9] Gain saturation of nickel-like silver and tin x-ray lasers by use of a tabletop pumping laser system
    Kawachi, T
    Kado, M
    Tanaka, M
    Sasaki, A
    Hasegawa, N
    Kilpio, AV
    Namba, S
    Nagashima, K
    Lu, PX
    Takahashi, K
    Tang, HJ
    Tai, RZ
    Kishimoto, M
    Koike, M
    Daido, H
    Kato, Y
    [J]. PHYSICAL REVIEW A, 2002, 66 (03): : 338151 - 338157