X-Ray Refractive Large Aperture Rolled Prism Lenses as Condensers for X-Ray Tubes

被引:3
|
作者
Vogt, H. [1 ]
Simon, M. [1 ]
Last, A. [1 ]
Marschall, F.
Mohr, J. [1 ]
Nazmov, V. [1 ]
Eisenhower, R. [2 ]
Mettendorf, K. U. [2 ]
机构
[1] Karlsruhe Inst Technol, IMT, Postfach 3640, D-76021 Karlsruhe, Germany
[2] Bruker AXS GmbH, D-76187 Karlsruhe, Germany
来源
OPTICAL DESIGN AND ENGINEERING IV | 2011年 / 8167卷
关键词
large aperture; x-ray lens; condenser; x-ray tube; x-ray imaging;
D O I
10.1117/12.897004
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
At the Institute of Microstructure Technology (IMT) at Karlsruhe Institute of Technology (KIT), refractive X-ray optics are developed. These optics are proposed to be used as condenser optics in X-Ray spectroscopy and microscopy applications with an X-ray tube as a source. To produce the lenses, a thin structured foil with equidistant fins in triangular form is casted from a structured silicon wafer. The foil is then wound around a glass fibre core. Due to this fabrication method, it is possible to produce large-aperture lenses with low absorption in comparison to other types of refractive X-Ray optics, like X-Ray lenses with continuous parabolic shape or prism lenses. The first are limited due to their absorption while the latter are limited due to their mechanical stability of the prism columns. The optimisation of the so called X-Ray rolled prism lenses (RXPL) is underway at the institute and involves several parameters. One important property of the lenses is the correct form of the wound foil layers. This determines the number of necessary refractive elements at a given radius, which in turn determines the refracted slope and focal position of the transmitted beam. The spatial extent of the x-ray source is also being accounted for in the lens design. Another important point is the diameter of the winding core, which should be as small as possible due to the fact that the winding core reduces the active area of the lens. The rolling process itself is also revised to produce lenses with the above-mentioned small diameter winding cores and bend foil layers while sustaining a tight- fitting foil bundle. The lenses are studied at different energies and types of X-Ray tubes, as well as synchrotron sources, to gain additional information of the internal structure of the lens after the winding process. In this paper the current status of the lens development and results at X-Ray tube sources for use in diffractometers is presented.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] NEW X-RAY TUBES FOR WAFER LEVEL INSPECTION
    Bryant, Keith
    2020 INTERNATIONAL WAFER LEVEL PACKAGING CONFERENCE (IWLPC), 2020,
  • [32] Refractive X-ray shape memory polymer 3D lenses with axial symmetry
    Pavlov, G.
    Snigireva, I.
    Snigirev, A.
    Sagdullin, T.
    Schmidt, M.
    X-RAY SPECTROMETRY, 2012, 41 (05) : 313 - 315
  • [33] A microfocus X-ray tube based on a microstructured X-ray target
    Ihsan, Aamir
    Heo, Sung Hwan
    Cho, Sung Oh
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (21-22) : 3566 - 3573
  • [34] LOFT - the Large Observatory For x-ray Timing
    Feroci, M.
    den Herder, J. W.
    Bozzo, E.
    Barret, D.
    Brandt, S.
    Hernanz, M.
    van der Klis, M.
    Pohl, M.
    Santangelo, A.
    Stella, L.
    Watts, A.
    Wilms, J.
    Zane, S.
    Ahangarianabhari, M.
    Alpar, A.
    Altamirano, D.
    Alvarez, L.
    Amati, L.
    Amoros, C.
    Andersson, N.
    Antonelli, A.
    Argan, A.
    Artigue, R.
    Azzarello, P.
    Baldazzi, G.
    Balman, S.
    Barbera, M.
    Belloni, T.
    Bertuccio, G.
    Bianchi, S.
    Bianchini, A.
    Bodin, P.
    Bidaud, J. -M. Bonnet
    Boutloukos, S.
    Braga, J.
    Brown, E.
    Bucciantini, N.
    Burderi, L.
    Bursa, M.
    Budtz-Jorgensen, C.
    Cackett, E.
    Cadoux, F. R.
    Cais, P.
    Caliandro, G. A.
    Campana, R.
    Campana, S.
    Casella, P.
    Chakrabarty, D.
    Chenevez, J.
    Coker, J.
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [35] Wide-area phase-contrast X-ray imaging using large X-ray interferometers
    Momose, A
    Takeda, T
    Yoneyama, A
    Koyama, I
    Itai, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 917 - 920
  • [36] Research on X-ray Tube Characteristics Facing X-ray Fluorescence Spectrometer
    Chang, Zeyuan
    Gao, Ran
    Zhang, Qi
    Teng, Yun
    Rao, Lan
    Cao, Zhewei
    2022 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE, ACP, 2022, : 1468 - 1471
  • [37] New achievements in X-ray optics - the X-ray lens and its applications
    Yan, YM
    He, YJ
    Ding, XL
    Chen, J
    Li, Y
    Wei, FZ
    Xie, JD
    Pan, QL
    Wang, DC
    PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2001, 11 (02) : 87 - 93
  • [38] Secondary radiation in transmission-type X-ray tubes: Simulation, practical issues and solution in the context of X-ray microtomography
    Boone, Matthieu N.
    Vlassenbroeck, Jelle
    Peetermans, Steven
    Van Loo, Denis
    Dierick, Manuel
    Van Hoorebeke, Luc
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 661 (01) : 7 - 12
  • [39] Using of a microcapillary refractive X-ray lens for focusing and imaging
    Dudchik, Yu. I.
    Komarov, F. F.
    Piestrup, M. A.
    Gary, C. K.
    Park, H.
    Cremer, J. T.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (6-7) : 598 - 602
  • [40] Hard X-ray imaging by a spherical compound refractive lens
    Huang, Chengchao
    Mu, Baozhong
    Wang, Zhanshan
    Chen, Lingyan
    Dudchik, Yu. I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 602 (02) : 446 - 449