Ultimate and nominal shear strength in reinforced concrete beams deteriorated by corrosion

被引:73
作者
Juarez, C. A. [1 ]
Guevara, B. [1 ]
Fajardo, G. [1 ]
Castro-Borges, P. [2 ]
机构
[1] UANL, Fac Ingn Civil, Acad Grp Concrete Technol, San Nicolas De Los Garza, NL, Mexico
[2] CINVESTAV IPN, Dept Appl Phys, Merida, Yucatan, Mexico
关键词
Shear strength; Diagonal tension; Corrosion; Stirrups; Concrete; COVER CRACKING; PERFORMANCE; CAPACITY;
D O I
10.1016/j.engstruct.2011.08.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Exposure to aggressive agents such as chlorides facilitates the corrosion process of the transversal reinforcement (stirrups) of concrete beams, as the steel of these reinforcements is closest to the concrete's surface. Two groups of eight beams each were fabricated, and had a separation of either 150 or 200 mm between stirrups for each series. During the first stage, beams were exposed to wetting cycles using a 3.5% NaCl solution, and were then subjected to a drying process until steel depassivation was reached. Subsequently, a 100 mu A/cm(2) printed current was applied for either 80 (moderate) or 120 (severe) days in order to reach different levels of corrosion in the stirrups. Results showed that the ultimate shear strength was influenced mainly by moderate and severe levels of deterioration, as beams subjected to these treatment levels showed a 30% decrease in ultimate shear strength relative to control beams. Additionally, beam ductility was affected by levels of moderate and severe deterioration of stirrups, and this was evident due to the brittleness and sudden failure observed during beam testing. Finally, our findings indicated that the average remaining section based on the critical diameter of the stirrups was a reliable predictor of ultimate shear strength. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3189 / 3196
页数:8
相关论文
共 30 条
[1]  
Ahmed SFU, 2007, ACI MATER J, V104, P153
[2]   COVER CRACKING AS A FUNCTION OF BAR CORROSION .1. EXPERIMENTAL TEST [J].
ANDRADE, C ;
ALONSO, C ;
MOLINA, FJ .
MATERIALS AND STRUCTURES, 1993, 26 (162) :453-464
[3]  
[Anonymous], 2009, C876 ASTM, DOI [10.1520/C0876-09, DOI 10.1520/C0876-09]
[4]  
[Anonymous], 2008, ACI 318-08) and commentary
[5]  
[Anonymous], 2011, ASTM G01-03, DOI [10.1520/G0001-03R11, DOI 10.1520/G0001-03R11]
[6]  
ASTM, 2022, ASTM A615/A615M-09b, DOI [10.1520/A0615_A0615M-09B, DOI 10.1520/A0615_A0615M-09B]
[7]  
ASTM Committee C09, 2010, ASTM Standards, V04.02, DOI [10.1520/C0039_C0039M-10, DOI 10.1520/C0039_C0039M-10]
[8]  
Auyeung Y, 2000, ACI MATER J, V97, P214
[9]  
AVELDANO RR, 2001, INFLUENCIA DISTRIBUC, P715
[10]  
Azad AK, 2007, ACI MATER J, V104, P40