Two repetition time saturation transfer (TwiST) with spill-over correction to measure creatine kinase reaction rates in human hearts

被引:22
作者
Schaer, Michael [1 ]
Gabr, Refaat E. [2 ]
El-Sharkawy, AbdEl-Monem M. [1 ,3 ]
Steinberg, Angela [4 ]
Bottomley, Paul A. [1 ]
Weiss, Robert G. [1 ,4 ]
机构
[1] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Div MR Res, Baltimore, MD 21218 USA
[2] Univ Texas Hlth Sci Ctr Houston, Dept Diagnost & Intervent Imaging, Houston, TX 77030 USA
[3] Cairo Univ, Syst & Biomed Engn Dept, Fac Engn, Giza, Egypt
[4] Johns Hopkins Univ, Sch Med, Dept Med, Div Cardiol, Baltimore, MD 21205 USA
关键词
Saturation transfer; Human heart; Metabolism; Reaction rate; High-energy phosphate; Heart failure; 3; Tesla; Creatine-kinase; TwiST; P-31; SPECTROSCOPY; METABOLITES; KINETICS; EXCHANGE; DISEASE; MUSCLE; FLUX;
D O I
10.1186/s12968-015-0175-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Phosphorus saturation transfer (ST) magnetic resonance spectroscopy can measure the rate of ATP generated from phosphocreatine (PCr) via creatine kinase (CK) in the human heart. Recently, the triple-repetition time ST (TRiST) method was introduced to measure the CK pseudo-first-order rate constant k(f) in three acquisitions. In TRiST, the longitudinal relaxation time of PCr while gamma-ATP is saturated, T-1', is measured for each subject, but suffers from low SNR because the PCr signal is reduced due to exchange with saturated gamma-ATP, and the short repetition time of one of the acquisitions. Here, a two-repetition time ST (TwiST) method is presented. In TwiST, the acquisition with gamma-ATP saturation and short repetition time is dropped. Instead of measuring T-1' an intrinsic relaxation time T-1 for PCr, T-1(intrinsic), is assumed. The objective was to validate TwiST measurements of CK kinetics in healthy subjects and patients with heart failure (HF). Methods: Bloch equation simulations that included the effect of spillover irradiation on PCr were used to derive formulae for T-1(intrinsic) and k(f) measured by both TRiST and TwiST methods. Spillover was quantified from an unsaturated PCr measurement used in the current protocol for determining PCr and ATP concentrations. Cardiac TRiST and TwiST data were acquired at 3 T from 12 healthy and 17 HF patients. Results: Simulations showed that both k(f) measured by TwiST and T-1(intrinsic) require spill-over corrections. In human heart at 3 T, the spill-over corrected T-1(intrinsic) = 8.4 +/- 1.4 s (mean +/- SD) independent of study group. TwiST and TRiST k(f) measurements were the same, but TwiST was 9 min faster. Spill-over corrected TwiST k(f) was 0.33 +/- 0.08 s(-1) vs. 0.20 +/- 0.06 s(-1) in healthy vs HF hearts, respectively (p < 0.0001). Conclusion: TwiST was validated against TRiST in the human heart at 3 T, generating the same results 9 min faster. TwiST detected significant reductions in CK k(f) in HF compared to healthy subjects, consistent with prior 1.5 T studies using different methodology.
引用
收藏
页数:11
相关论文
共 27 条
[1]   Reproducibility of creatine kinase reaction kinetics in human heart: a 31P time-dependent saturation transfer spectroscopy study [J].
Bashir, Adil ;
Gropler, Robert .
NMR IN BIOMEDICINE, 2014, 27 (06) :663-671
[2]   Absolute concentrations of high-energy phosphate metabolites in normal, hypertrophied, and failing human myocardium measured noninvasively with 31P-SLOOP magnetic resonance spectroscopy [J].
Beer, M ;
Seyfarth, T ;
Sandstede, J ;
Landschütz, W ;
Lipke, C ;
Köstler, H ;
von Kienlin, M ;
Harre, K ;
Hahn, D ;
Neubauer, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (07) :1267-1274
[3]   Four-angle saturation transfer (FAST) method for measuring creatine kinase reaction rates in vivo [J].
Bottomley, PA ;
Ouwerkerk, R ;
Lee, RF ;
Weiss, RG .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) :850-863
[4]   Metabolic Rates of ATP Transfer Through Creatine Kinase (CK Flux) Predict Clinical Heart Failure Events and Death [J].
Bottomley, Paul A. ;
Panjrath, Gurusher S. ;
Lai, Shenghan ;
Hirsch, Glenn A. ;
Wu, Katherine ;
Najjar, Samer S. ;
Steinberg, Angela ;
Gerstenblith, Gary ;
Weiss, Robert G. .
SCIENCE TRANSLATIONAL MEDICINE, 2013, 5 (215)
[5]   Reduced Myocardial Creatine Kinase Flux in Human Myocardial Infarction An In Vivo Phosphorus Magnetic Resonance Spectroscopy Study [J].
Bottomley, Paul A. ;
Wu, Katherine C. ;
Gerstenblith, Gary ;
Schulman, Steven P. ;
Steinberg, Angela ;
Weiss, Robert G. .
CIRCULATION, 2009, 119 (14) :1918-1924
[6]  
Brown TR., 1978, FRONTIERS BIOL ENERG, P1341
[7]   Quantitative Cardiac 31P Spectroscopy at 3 Tesla Using Adiabatic Pulses [J].
El-Sharkawy, AbdEl-Monem ;
Schar, Michael ;
Ouwerkerk, Ronald ;
Weiss, Robert G. ;
Bottomley, Paul A. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (04) :785-795
[8]   Quantification of human high-energy phosphate metabolite concentrations at 3 T with partial volume and sensitivity corrections [J].
El-Sharkawy, AbdEl-Monem M. ;
Gabr, Refaat E. ;
Schaer, Michael ;
Weiss, Robert G. ;
Bottomley, Paul A. .
NMR IN BIOMEDICINE, 2013, 26 (11) :1363-1371
[9]   STUDY OF MODERATELY RAPID CHEMICAL EXCHANGE REACTIONS BY MEANS OF NUCLEAR MAGNETIC DOUBLE RESONANCE [J].
FORSEN, S ;
HOFFMAN, RA .
JOURNAL OF CHEMICAL PHYSICS, 1963, 39 (11) :2892-&
[10]   PHOSPHOCREATINE-T(1) MEASUREMENTS WITH AND WITHOUT EXCHANGE IN THE HEART [J].
FRIEDRICH, J ;
NASCIMBEN, L ;
LIAO, R ;
INGWALL, JS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (01) :45-50