摘要
One major hindrance to more utilization of timber in the construction of tall buildings is the limited fire resistance of the connections between its structural elements. In an experimental study that aimed to investigate the structural behaviour of a new connection configuration that utilizes fully concealed, mechanically fastened steel rods, eight (8) full-size glued-laminated timber beam-end connections were tested under the CAN/ULC-S101 standard time-temperature curve. Test variables investigated in this study included rod anchorage length (200 and 250 mm) and washer size (38.1 x 38.1 and 50.8 x 50.8 mm). Results show that using the smaller washer provided more wood side cover to protect the steel components from the effects of elevated temperatures. Also, utilizing longer rod anchorage length provided larger internal surface area of the wood prism to better resist shear stresses as well as longer length for the rods to bear against the wood at high rotation values of the connection. By combining the said two aspects (longer anchorage length and smaller washer) a fully concealed glulam beam-end connection that utilizes only two mechanically-fastened steel rods can be successfully designed to achieve a 1-h fire resistance without the application of additional fire protection.
引用
收藏
页数:13
相关论文
共 20 条
  • [1] American Wood Council (AWC), 2017, NAT DES SPEC WOOD CO, V2018
  • [2] [Anonymous], 2013, General Requirements for Rolled or Welded Structural Quality Steel
  • [3] Behavior of dowelled and bolted steel-to-timber connections exposed to fire
    Audebert, M.
    Dhima, D.
    Taazount, M.
    Bouchair, A.
    [J]. ENGINEERING STRUCTURES, 2012, 39 : 116 - 125
  • [4] Determination of fire resistance ratings for glulam connectors within US high rise timber buildings
    Barber, David
    [J]. FIRE SAFETY JOURNAL, 2017, 91 : 579 - 585
  • [5] Batchelar ML, 1998, 5TH WORLD CONFERENCE ON TIMBER ENGINEERING, VOL 1, PROCEEDINGS, P289
  • [6] Bisby L., 2013, Fire Science Reviews, DOI DOI 10.1186/2193-0414-2-1
  • [7] CCMC, 2018, Canadian ConstructionMaterials Centre Report No. 13216-R
  • [8] CSA (Canadian Standards Association), 2019, Engineering design in wood
  • [9] Influence of elevated temperature on glued-in steel rods for timber elements
    Di Maria, Valentina
    D'Andria, Luca
    Muciaccia, Giovanni
    Ianakiev, Anton
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2017, 147 : 457 - 465
  • [10] Timber Frame Moment Joints with Glued-In Steel Rods. I: Design
    Fragiacomo, Massimo
    Batchelar, Mark
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2012, 138 (06) : 789 - 801