Prediction of biomechanical properties of articular cartilage with quantitative magnetic resonance imaging

被引:113
作者
Nieminen, MT
Töyräs, J
Laasanen, MS
Silvennoinen, J
Helminen, HJ
Jurvelin, JS
机构
[1] Univ Kuopio, Dept Anat, FIN-70211 Kuopio, Finland
[2] Univ Kuopio, Dept Appl Phys, FIN-70211 Kuopio, Finland
[3] Univ Kuopio, AI Virtanen Inst Mol Sci, Natl Bio NMR Facil, FIN-70211 Kuopio, Finland
[4] Kuopio Univ Hosp, Dept Clin Physiol & Nucl Med, SF-70210 Kuopio, Finland
关键词
articular cartilage; biomechanics; MRI; collagen; proteoglycans;
D O I
10.1016/S0021-9290(03)00291-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Quantitative magnetic resonance imaging (MRI) is the most potential non-invasive means for revealing the structure, composition and pathology of articular cartilage. Here we hypothesize that cartilage mechanical properties as determined by the macromolecular framework and their interactions can be accessed by quantitative MRI. To test this, adjacent cartilage disk pairs (n = 32) were prepared from bovine proximal humerus and patellofemoral surfaces. For one sample, the tissue Young's modulus, aggregate modulus, dynamic modulus and Poisson's ratio were determined in unconfined compression. The adjacent disk was studied at 9.4 T to determine the tissue T(2) relaxation time, sensitive to the integrity of the collagen network, and T(1) relaxation time in the presence of Gd-DTPA. a technique developed for the estimation of cartilage proteoglycan (PG) content. Quantitative MRI parameters were able to explain up to 87% of the variations in certain biomechanical parameters. Correlations were further improved when data from the proximal humerus was assessed separately. MRI parameters revealed a topographical variation similar to that of mechanical parameters. Linear regression analysis revealed that Young's modulus of cartilage may be characterized more completely by combining both collagen- and PG-sensitive MRI parameters. The present results suggest that quantitative MRI can provide important information on the mechanical properties of articular cartilage. The results are encouraging with respect to functional imaging of cartilage, although in vivo applicability may be limited by the inferior resolution of clinical MRI instruments. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:321 / 328
页数:8
相关论文
共 49 条
[21]   COMPARISON OF OPTICAL, NEEDLE PROBE AND ULTRASONIC TECHNIQUES FOR THE MEASUREMENT OF ARTICULAR-CARTILAGE THICKNESS [J].
JURVELIN, JS ;
RASANEN, T ;
KOLMONEN, P ;
LYYRA, T .
JOURNAL OF BIOMECHANICS, 1995, 28 (02) :231-235
[22]   Topographical variation of the elastic properties of articular cartilage in the canine knee [J].
Jurvelin, JS ;
Arokoski, JPA ;
Hunziker, EB ;
Helminen, HJ .
JOURNAL OF BIOMECHANICS, 2000, 33 (06) :669-675
[23]   Fibril reinforced poroelastic model predicts specifically mechanical behavior of normal, proteoglycan depleted and collagen degraded articular cartilage [J].
Korhonen, RK ;
Laasanen, MS ;
Töyräs, J ;
Lappalainen, R ;
Helminen, HJ ;
Jurvelin, JS .
JOURNAL OF BIOMECHANICS, 2003, 36 (09) :1373-1379
[24]   Importance of the superficial tissue layer for the indentation stiffness of articular cartilage [J].
Korhonen, RK ;
Wong, M ;
Arokoski, J ;
Lindgren, R ;
Helminen, HJ ;
Hunziker, EB ;
Jurvelin, JS .
MEDICAL ENGINEERING & PHYSICS, 2002, 24 (02) :99-108
[25]  
Laasanen MS, 2003, BIORHEOLOGY, V40, P133
[26]   A TRIPHASIC THEORY FOR THE SWELLING AND DEFORMATION BEHAVIORS OF ARTICULAR-CARTILAGE [J].
LAI, WM ;
HOU, JS ;
MOW, VC .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1991, 113 (03) :245-258
[27]   Evaluation of water content by spatially resolved transverse relaxation times of human articular cartilage [J].
Lüsse, S ;
Claassen, H ;
Gehrke, T ;
Hassenpflug, J ;
Schünke, M ;
Heller, M ;
Glüer, CC .
MAGNETIC RESONANCE IMAGING, 2000, 18 (04) :423-430
[28]   INDENTATION INSTRUMENT FOR THE MEASUREMENT OF CARTILAGE STIFFNESS UNDER ARTHROSCOPIC CONTROL [J].
LYYRA, T ;
JURVELIN, J ;
PITKANEN, P ;
VAATAINEN, U ;
KIVIRANTA, I .
MEDICAL ENGINEERING & PHYSICS, 1995, 17 (05) :395-399
[29]   Optimization of the arthroscopic indentation instrument for the measurement of thin cartilage stiffness [J].
Lyyra-Laitinen, T ;
Niinimäki, M ;
Töyräs, J ;
Lindgren, R ;
Kiviranta, I ;
Jurvelin, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (10) :2511-2524
[30]   T2 quantitation of articular cartilage at 1.5 T [J].
Maier, CF ;
Tan, SG ;
Hariharan, H ;
Potter, HG .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :358-364