Interobserver Reliability of Schatzker, AO Foundation-Orthopaedic Trauma Association, and Luo Classifications for Tibial Plateau Fractures: Does Three-Dimensional CT Improve Outcomes?

被引:5
|
作者
Masouros, Panagiotis T. [1 ]
Mitrogiannis, George [1 ]
Antoniou, Georgia [1 ]
Chatzidaki, Christina [1 ]
Kourtzis, Dimitrios [1 ]
Garnavos, Christos [1 ]
机构
[1] Evangelismos Gen Hosp, Orthopaed, Athens, Greece
关键词
interobserver reliability; ao-ota classification; luo; schatzker; classification; tibial plateau fracture; COMPUTED-TOMOGRAPHY;
D O I
10.7759/cureus.22227
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To assess the interobserver agreement of the most widely used classification systems (Schatzker, AO Foundation-Orthopaedic Trauma Association (AO-OTA), and Luo) and investigate the impact of multiplane CT scans on their reliability. Methods Twelve raters (seven consultants and five senior trainees) were invited to classify 25 cases of tibial plateau fracture randomly selected out of a large database. Initially, they were asked to classify the fracture according to Schatzker, AO-OTA, and Luo based on plain anteroposterior (AP) X-ray and axial CT images. This procedure was applied for 25 cases consecutively. Next, the raters are given access to the multiplanar CT views of the same cases and were requested to reclassify each case. The interobserver agreement was calculated using the Fleiss kappa coefficient. Results An overall fair inter-rater agreement was observed for the Schatzker classification based on the plain AP Xray (k=0.361) with a slight improvement after three-dimensional (3D) plane CT views (X-ray: k=0.361; 3D CT: k=0.364). For the AO-OTA classification, the relevant values were 0.204 and 0.231 based on plain X-ray and multiplanar CT, respectively. Finally, the Luo classification achieved the highest scores among the three classification systems (k=0.498), but its inter-rater agreement can still be characterized as moderate. No statistically significant improvement in the interobserver agreement was found for any classification even if only the consultants' subgroup was included in the data analysis. Conclusion All three classification systems failed to achieve a substantial agreement among the raters, with only a nonsignificant improvement after providing advanced imaging. This finding reflects the intrinsic weaknesses of the classification systems themselves rather than the disagreement on the fracture pattern due to unsatisfactory imaging.
引用
收藏
页数:5
相关论文
共 5 条
  • [1] INTER- AND INTRA-OBSERVER RELIABILITY OF SCHATZKER, AO, AND LUO CLASSIFICATIONS FOR TIBIAL PLATEAU FRACTURES
    de Alencar Neto, Jonatas Brito
    Duarte de Souza, Clodoaldo Jose
    Reis Coelho, Pedro Rafael
    de Freitas Junior, Pedro Gomes
    Gadelha Lopes, Marcio Bezerra
    Maia Pinto, Francisco Jose
    ACTA ORTOPEDICA BRASILEIRA, 2020, 28 (05): : 216 - 220
  • [2] Three-Dimensional Computed Tomography Reconstructions Do Not Improve the Interobserver Reliability of the AO/Orthopaedic Trauma Association and Young and Burgess Pelvic Fracture Classifications
    Byun, Seong-Eun
    Hwang, Jihyo
    Salameh, Motasem
    Tucker, Nicholas J.
    Hadeed, Michael
    Heare, Austin
    Stacey, Stephen C.
    Mauffrey, Cyril
    Parry, Joshua A.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2022, 56 (06) : 1018 - 1022
  • [3] Three-Dimensional Computed Tomography Reconstructions Do Not Improve the Interobserver Reliability of the AO/Orthopaedic Trauma Association and Young and Burgess Pelvic Fracture Classifications
    Seong-Eun Byun
    Jihyo Hwang
    Motasem Salameh
    Nicholas J. Tucker
    Michael Hadeed
    Austin Heare
    Stephen C. Stacey
    Cyril Mauffrey
    Joshua A. Parry
    Indian Journal of Orthopaedics, 2022, 56 : 1018 - 1022
  • [4] Automatic segmentation of knee CT images of tibial plateau fractures based on three-dimensional U-Net: Assisting junior physicians with Schatzker classification
    Cai, Die
    Zhou, Yu
    He, Wenjie
    Yuan, Jichun
    Liu, Chenyuan
    Li, Rui
    Wang, Yi
    Xia, Jun
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 178
  • [5] The impact of stereo-visualisation of three-dimensional CT datasets on the inter- and intraobserver reliability of the AO/OTA and Neer classifications in the assessment of fractures of the proximal humerus
    Brunner, A.
    Honigmann, P.
    Treumann, T.
    Babst, R.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (06): : 766 - 771