Effects of shell-integrated Sudan Black dye on the acoustic activity and ultrasound imaging properties of lipid-shelled nanoscale ultrasound contrast agents

被引:2
作者
Wegierak, Dana [1 ,2 ]
Fishbein, Grace [1 ]
Abenojar, Eric [3 ]
Al De Leon [3 ]
Zhu, Jinle [3 ]
Wang, Yanjie [1 ]
Ferworn, Charlotte [1 ]
Exner, Agata A. [2 ,3 ]
Kolios, Michael C. [1 ]
机构
[1] Ryerson Univ, Dept Phys, Fac Sci, Toronto, ON, Canada
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Dept Radiol, Cleveland, OH 44106 USA
基金
美国国家卫生研究院;
关键词
nanobubbles; contrast agents; photoacoustic imaging; ultrasound imaging; multimodal imaging; rectified diffusion; MICROBUBBLES; DELIVERY; NANOPARTICLES; NANODROPLETS; VASCULATURE; CAVITATION; SCATTERING; BUBBLES;
D O I
10.1117/1.JBO.27.1.016501
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: An effective contrast agent for concurrent multimodal photoacoustic (PA) and ultrasound (US) imaging must have both high optical absorption and high echogenicity. Integrating a highly absorbing dye into the lipid shell of gas core nanobubbles (NBs) adds PA contrast to existing US contrast agents but may impact agent ultrasonic response. Aim: We report on the development and ultrasonic characterization of lipid-shell stabilized C3F8 NBs with integrated Sudan Black (SB) B dye in the shell as dual-modal PA-US contrast agents. Approach: Perfluoropropane NBs stabilized with a lipid shell including increasing concentrations of SB B dye were formulated by amalgamation (SBNBs). Physical properties of SBNBs were characterized using resonant mass measurement, transmission electron microscopy and pendant drop tensiometry. Concentrated bubble solutions were imaged for 8 min to assess signal decay. Diluted bubble solutions were stimulated by a focused transducer to determine the response of individual NBs to long cycle (30 cycle) US. For assessment of simultaneous multimodal contrast, bulk populations of SBNBs were imaged using a PA and US imaging platform. Results: We produced high agent yield (similar to 10(11)) with a mean diameter of similar to 200 to 300 nm depending on SB loading. A 40% decrease in bubble yield was measured for solutions with 0.3 and 0.4 mg/ml SB. The addition of SB to the shell did not substantially affect NB size despite an increase in surface tension by up to 8 mN/m. The bubble decay rate increased after prolonged exposure (8 min) by dyed bubbles in comparison to their undyed counterparts (2.5-fold). SB in bubble shells increased gas exchange across the shell for long cycle US. PA imaging of these agents showed an increase in power (up to 10 dB) with increasing dye. Conclusions: We added PA contrast function to NBs. The addition of SB increased gas exchange across the NB shell. This has important implications in their use as multimodal agents. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License.
引用
收藏
页数:18
相关论文
共 60 条
  • [1] Pickering Bubbles as Dual-Modality Ultrasound and Photoacoustic Contrast Agents
    Al de Leon
    Wei, Peiran
    Bordera, Filip
    Wegierak, Dana
    McMillen, Madelyn
    Yan, David
    Hemmingsen, Christina
    Kolios, Michael C.
    Pentzer, Emily B.
    Exner, Agata A.
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (19) : 22308 - 22317
  • [2] Optical Scattering Properties of Intralipid Phantom in Presence of Encapsulated Microbubbles
    Assadi, Homa
    Karshafian, Raffi
    Douplik, Alexandre
    [J]. INTERNATIONAL JOURNAL OF PHOTOENERGY, 2014, 2014
  • [3] High-frequency ultrasound scattering from microspheres and single cells
    Baddour, RE
    Sherar, MD
    Hunt, JW
    Czarnota, GJ
    Kolios, MC
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2005, 117 (02) : 934 - 943
  • [4] Biomedical photoacoustic imaging
    Beard, Paul
    [J]. INTERFACE FOCUS, 2011, 1 (04) : 602 - 631
  • [5] Measurement of surface and interfacial tension using pendant drop tensiometry
    Berry, Joseph D.
    Neeson, Michael J.
    Dagastine, Raymond R.
    Chan, Derek Y. C.
    Tabor, Rico F.
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2015, 454 : 226 - 237
  • [6] Bodera FJ, 2018, IEEE INT ULTRA SYM
  • [7] Clinical applications of indocyanine green (ICG) enhanced fluorescence in laparoscopic surgery
    Boni, Luigi
    David, Giulia
    Mangano, Alberto
    Dionigi, Gianlorenzo
    Rausei, Stefano
    Spampatti, Sebastiano
    Cassinotti, Elisa
    Fingerhut, Abe
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (07): : 2046 - 2055
  • [8] Photoacoustic and Ultrasound Dual-Mode Imaging via Functionalization of Recombinant Protein-Stabilized Microbubbles with Methylene Blue
    Chen, Zhuo
    Chattaraj, Rajarshi
    Pulsipher, Katherine W.
    Karmacharya, Mrigendra B.
    Hammer, Daniel A.
    Lee, Daeyeon
    Sehgal, Chandra M.
    [J]. ACS APPLIED BIO MATERIALS, 2019, 2 (09) : 4020 - 4026
  • [9] Imaging with ultrasound contrast agents: current status and future
    Chong, Wui K.
    Papadopoulou, Virginie
    Dayton, Paul A.
    [J]. ABDOMINAL RADIOLOGY, 2018, 43 (04) : 762 - 772
  • [10] Ultrasound contrast agents: An overview
    Cosgrove, David
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) : 324 - 330