Improving Data Glove Accuracy and Usability Using a Neural Network When Measuring Finger Joint Range of Motion

被引:8
|
作者
Connolly, James [1 ]
Condell, Joan [2 ]
Curran, Kevin [2 ]
Gardiner, Philip [2 ]
机构
[1] Letterkenny Inst Technol, Letterkenny F92 FC93, Donegal, Ireland
[2] Ulster Univ, Sch Comp Engn & Intelligent Syst, Derry BT48 7JL, Londonderry, North Ireland
关键词
data glove; sensor calibration; joint range of motion; kinematics; neural network; INSTRUMENTED GLOVE; HAND;
D O I
10.3390/s22062228
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Data gloves capable of measuring finger joint kinematics can provide objective range of motion information useful for clinical hand assessment and rehabilitation. Data glove sensors are strategically placed over specific finger joints to detect movement of the wearers' hand. The construction of the sensors used in a data glove, the number of sensors used, and their positioning on each finger joint are influenced by the intended use case. Although most glove sensors provide reasonably stable linear output, this stability is influenced externally by the physical structure of the data glove sensors, as well as the wearer's hand size relative to the data glove, and the elastic nature of materials used in its construction. Data gloves typically require a complex calibration method before use. Calibration may not be possible when wearers have disabled hands or limited joint flexibility, and so limits those who can use a data glove within a clinical context. This paper examines and describes a unique approach to calibration and angular calculation using a neural network that improves data glove repeatability and accuracy measurements without the requirement for data glove calibration. Results demonstrate an overall improvement in data glove measurements. This is particularly relevant when the data glove is used with those who have limited joint mobility and cannot physically complete data glove calibration.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] A technique for motion capture of the finger using functional joint centres and the effect of calibration range of motion on its accuracy
    Warlow, Oliver M. E.
    Lawson, Sian E. M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H5) : 360 - 367
  • [2] A technique for motion capture of the finger using functional joint centres and the effect of calibration range of motion on its accuracy
    Warlow, Oliver M.E.
    Lawson, Sian E.M.
    Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2012, 226 (05) : 360 - 367
  • [3] Accuracy and Reliability of Visual Inspection and Smartphone Applications for Measuring Finger Range of Motion
    Lee, Hannah H.
    St Louis, Kwesi
    Fowler, John R.
    ORTHOPEDICS, 2018, 41 (02) : E217 - E221
  • [4] Improving the measuring length accuracy of articulated arm coordinate measuring machine using artificial neural network
    Zhao, Huining
    Yu, Liandong
    Cao, Jiaming
    Jia, Huakun
    Jiang, Yizhou
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (12):
  • [5] Human-computer interaction system with artificial neural network using motion tracker and data glove
    Oz, C
    Leu, MC
    PATTERN RECOGNITION AND MACHINE INTELLIGENCE, PROCEEDINGS, 2005, 3776 : 280 - 286
  • [6] Recognition of finger spelling of American sign language with artificial neural network using position/orientation sensors and data glove
    Oz, C
    Leu, MC
    ADVANCES IN NEURAL NETWORKS - ISNN 2005, PT 2, PROCEEDINGS, 2005, 3497 : 157 - 164
  • [7] Improving the ionospheric model accuracy using artificial neural network
    Sidorenko, K. A.
    Kondratyev, A. N.
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2020, 211
  • [8] Grasp Classification With Weft Knit Data Glove Using a Convolutional Neural Network
    Ayodele, Emmanuel
    Bao, Tianzhe
    Zaidi, Syed Ali Raza
    Hayajneh, Ali M. A.
    Scott, Jane
    Zhang, Zhi-Qiang
    McLernon, Des
    IEEE SENSORS JOURNAL, 2021, 21 (09) : 10824 - 10833
  • [9] Digital Testing Device for Active Range of Motion of Finger Joints Utilizing Artificial Neural Network
    Quang, Huu-Hieu
    Morita, Yoshifumi
    Takekawa, Makoto
    PROCEEDINGS OF THE 2021 INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS (ICAROB 2021), 2021, : P95 - P95
  • [10] Digital Testing Device for Active Range of Motion of Finger Joints Utilizing Artificial Neural Network
    Quang, Huu-Hieu
    Morita, Yoshifumi
    Takekawa, Makoto
    PROCEEDINGS OF THE 2021 INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS (ICAROB 2021), 2021, : 445 - 448