Smart patch integration development of compression connector structural health monitoring in overhead transmission lines

被引:1
|
作者
Wang, Hong [1 ]
Wang, Jy-An John [1 ]
Ren, Fei [2 ]
Chan, John [3 ]
机构
[1] Oak Ridge Natl Lab, Div Mat Sci & Technol, Oak Ridge, TN 37831 USA
[2] Temple Univ, Philadelphia, PA 19122 USA
[3] Elect Power Res Inst, 3412 Hillview Ave, Palo Alto, CA 94304 USA
来源
SMART MATERIALS AND NONDESTRUCTIVE EVALUATION FOR ENERGY SYSTEMS 2016 | 2016年 / 9806卷
关键词
PZT; smart patch; integration; structural health monitoring; compression connector; transmission lines; LEAD-ZIRCONATE-TITANATE; ELECTRIC-FIELD; STRENGTH;
D O I
10.1117/12.2218669
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Integration of smart patches into full-tension splice connectors in overhead power transmission lines was investigated. Lead zirconate titanate (PZT) -5A was used as a smart material and an aluminum beam was used as a host structure. Negative electrode termination was examined by using copper adhesive tape and direct bonding methods. Various commercial adhesives were studied for PZT integration onto the host structure. Aluminum beam specimens with integrated PZT smart patches were tested under thermal cycling at a temperature of 125 degrees C, which is the higher-end temperature experienced by in-service aluminum conductor steel-reinforced cables. Electromechanical impedance (EMI) measurements were conducted at room temperature, and the root mean square deviation (RMSD) of the conductance signals was used to analyze the EMI data. It has been shown that the negative electrode method has an important effect on the performance of the integrated PZT. The PZT displayed more susceptibility to cracking when copper tape was used than when direct bonding was used. The reliability of PZT in direct bonding depended on the adhesives used in bonding layers. Although a hard alumina-based adhesive can lead to cracking of the PZT, a high-temperature epoxy with adequate flexibility, such as Duralco 4538D, can provide the desired performance under target thermal cycling conditions. The RMSD parameter can characterize conductance signatures effectively. It also was demonstrated that RMSD can be used to quantify the fatigue of the PZT integration system, although RMSD is used primarily as a damage index in monitoring structural health.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Middleware services for structural health monitoring using smart sensors
    Nagayama, T.
    Spencer, B. F., Jr.
    Mechitov, K. A.
    Agha, G. A.
    SMART STRUCTURES AND SYSTEMS, 2009, 5 (02) : 119 - 137
  • [22] Recent progress in aircraft smart skin for structural health monitoring
    Wang, Yu
    Hu, Shuguang
    Xiong, Tao
    Huang, Yongan
    Qiu, Lei
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2022, 21 (05): : 2453 - 2480
  • [23] Energy Harvesting Device for Smart Monitoring of MV Overhead Power Lines-Theoretical Concept and Experimental Construction
    Bendik, Jozef
    Cenky, Matej
    Hromkovic, Oliver
    SENSORS, 2023, 23 (17)
  • [24] Integration of health monitoring and vibration control for smart building structures with time-varying structural parameters and unknown excitations
    Xu, Y. L.
    Huang, Q.
    Xia, Y.
    Liu, H. J.
    SMART STRUCTURES AND SYSTEMS, 2015, 15 (03) : 807 - 830
  • [25] Development of wireless smart sensor network for vibration-based structural health monitoring of civil structures
    Navabian, Niusha
    Beskhyroun, Sherif
    Matulich, Justin
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2022, 18 (03) : 345 - 361
  • [26] Approaches to Information Integration in Structural Health Monitoring Systems for Bridges
    Garita, Cesar
    TECNOLOGIA EN MARCHA, 2016, 29 (01): : 96 - 107
  • [27] Study of Smart Monitoring and Protection of Remote Transformers and Transmission Lines using GSM Technology
    Amesimenu, David Kwabena
    Chang, Kuo-Chi
    Sung, Tien-Wen
    Zhou, Yuwen
    Gakiza, Joram
    Omer, Abdalaziz Altayeb Ibrahim
    ahmad, Shoaib
    Chu, Kaichun
    Haque, Shamim Md Obaydul
    PROCEEDINGS OF 2020 IEEE INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND INFORMATION SYSTEMS (ICAIIS), 2020, : 297 - 301
  • [28] Development of an IoT Device for Structural Health Monitoring
    Seki, Keiju
    Nakasho, Kazuhisa
    Carlos, Cuadra
    Shimoi, Nobuhiro
    2022 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - TAIWAN, IEEE ICCE-TW 2022, 2022, : 519 - 520
  • [29] Study on Edge Extraction Methods for Image-based Icing On-line Monitoring on Overhead Transmission Lines
    Wang, Xiaopeng
    Hu, Jianlin
    Wu, Bin
    Du, Lin
    Sun, Caixin
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 661 - +
  • [30] Aeolian vibration-based structural health monitoring system for transmission line conductors
    Zhao, Long
    Huang, Xinbo
    Zhang, Ye
    Zhu, Yongcan
    Jia, Jianyuan
    Zhu, Chao
    STRUCTURAL CONTROL & HEALTH MONITORING, 2020, 27 (06)