Modification of a commercial atomic force microscopy for low-noise, high-resolution frequency-modulation imaging in liquid environment

被引:33
作者
Rode, S. [1 ]
Stark, R. [2 ]
Luebbe, J. [3 ]
Troeger, L. [3 ]
Schuette, J. [4 ]
Umeda, K. [4 ]
Kobayashi, K. [4 ]
Yamada, H. [4 ]
Kuehnle, A. [4 ]
机构
[1] Johannes Gutenberg Univ Mainz, Inst Phys Chem, Fachbereich Chem, D-55099 Mainz, Germany
[2] GKC O G201, BASF SE, D-67056 Ludwigshafen, Germany
[3] Univ Osnabruck, Fachbereich Phys, D-49076 Osnabruck, Germany
[4] Kyoto Univ, Dept Elect Sci & Engn, Nishikyo Ku, Kyoto 6158510, Japan
关键词
amplifiers; atomic force microscopy; calcium compounds; frequency modulation; image resolution; noise; optical sensors; photodiodes; sample holders;
D O I
10.1063/1.3606399
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A key issue for high-resolution frequency-modulation atomic force microscopy imaging in liquids is minimizing the frequency noise, which requires a detailed analysis of the corresponding noise contributions. In this paper, we present a detailed description for modifying a commercial atomic force microscope (Bruker MultiMode V with Nanoscope V controller), aiming at atomic-resolution frequency-modulation imaging in ambient and in liquid environment. Care was taken to maintain the AFMs original stability and ease of operation. The new system builds upon an optimized light source, a new photodiode and an entirely new amplifier. Moreover, we introduce a home-built liquid cell and sample holder as well as a temperature-stabilized isolation chamber dedicated to low-noise imaging in liquids. The success of these modifications is measured by the reduction in the deflection sensor noise density from initially 100 fm/root Hz to around 10 fm/root Hz after modification. The performance of our instrument is demonstrated by atomically resolved images of calcite taken under liquid conditions. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3606399]
引用
收藏
页数:7
相关论文
共 17 条
[1]   Development of liquid-environment frequency modulation atomic force microscope with low noise deflection sensor for cantilevers of various dimensions [J].
Fukuma, T ;
Jarvis, SP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (04)
[2]   Development of low noise cantilever deflection sensor for multienvironment frequency-modulation atomic force microscopy [J].
Fukuma, T ;
Kimura, M ;
Kobayashi, K ;
Matsushige, K ;
Yamada, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (05)
[3]   True atomic resolution in liquid by frequency-modulation atomic force microscopy [J].
Fukuma, T ;
Kobayashi, K ;
Matsushige, K ;
Yamada, H .
APPLIED PHYSICS LETTERS, 2005, 87 (03)
[7]   Forces and frequency shifts in atomic-resolution dynamic-force microscopy [J].
Giessibl, FJ .
PHYSICAL REVIEW B, 1997, 56 (24) :16010-16015
[8]   A Fabry-Perot interferometer for micrometer-sized cantilevers -: art. no. 074101 [J].
Hoogenboom, BW ;
Frederix, PLTM ;
Yang, JL ;
Martin, S ;
Pellmont, Y ;
Steinacher, M ;
Zäch, S ;
Langenbach, E ;
Heimbeck, HJ .
APPLIED PHYSICS LETTERS, 2005, 86 (07) :1-3
[9]   Visualizing water molecule distribution by atomic force microscopy [J].
Kimura, Kenjiro ;
Ido, Shinichiro ;
Oyabu, Noriaki ;
Kobayashi, Kei ;
Hirata, Yoshiki ;
Imai, Takashi ;
Yamada, Hirofumi .
JOURNAL OF CHEMICAL PHYSICS, 2010, 132 (19)
[10]   Frequency noise in frequency modulation atomic force microscopy [J].
Kobayashi, Kei ;
Yamada, Hirofumi ;
Matsushige, Kazumi .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (04)