Fatigue Behavior of Computer-Aided Design/Computer-Assisted Manufacture Ceramic Abutments as a Function of Design and Ceramics Processing

被引:23
作者
Kelly, J. Robert [1 ]
Rungruanganunt, Patchnee [1 ]
机构
[1] Univ Connecticut, Ctr Hlth, Dept Reconstruct Sci, 263 Farmington Ave, Farmington, CT 06030 USA
关键词
CAD/CAM abutments; fatigue; implant abutments; titanium; zirconia; IMPLANT ABUTMENTS; ZIRCONIA; RELIABILITY; MODES;
D O I
10.11607/jomi.4698
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Zirconia is being widely used, at times apparently by simply copying a metal design into ceramic. Structurally, ceramics are sensitive to both design and processing (fabrication) details. The aim of this work was to examine four computer-aided design/computer-assisted manufacture (CAD/CAM) abutments using a modified International Standards Organization (ISO) implant fatigue protocol to determine performance as a function of design and processing. Materials and Methods: Two full zirconia and two hybrid (Ti-based) abutments (n = 12 each) were tested wet at 15 Hz at a variety of loads to failure. Failure probability distributions were examined at each load, and when found to be the same, data from all loads were combined for lifetime analysis from accelerated to clinical conditions. Results: Two distinctly different failure modes were found for both full zirconia and Ti-based abutments. One of these for zirconia has been reported clinically in the literature, and one for the Ti-based abutments has been reported anecdotally. The ISO protocol modification in this study forced failures in the abutments; no implant bodies failed. Extrapolated cycles for 10% failure at 70 N were: full zirconia, Atlantis 2 x 10(7) and Straumann 3 x 10(7); and Ti-based, Glidewell 1 x 10(6) and Nobel 1 x 10(21). Under accelerated conditions (200 N), performance differed significantly: Straumann clearly outperformed Astra (t test, P = .013), and the Glidewell Ti-base abutment also outperformed Atlantis zirconia at 200 N (Nobel ran-out; t test, P = .035). Conclusion: The modified ISO protocol in this study produced failures that were seen clinically. The manufacture matters; differences in design and fabrication that influence performance cannot be discerned clinically.
引用
收藏
页码:601 / 609
页数:9
相关论文
共 9 条
[1]  
Aboushelib MN, 2009, INT J PROSTHODONT, V22, P616
[2]  
[Anonymous], 148012007 ISO
[3]   Influence of abutment-to-fixture design on reliability and failure mode of all-ceramic crown systems [J].
Delben, Juliana A. ;
Barao, Valentim A. R. ;
Ferreira, Mayara B. ;
da Silva, Nelson R. F. A. ;
Thompson, Van P. ;
Assuncao, Wirley G. .
DENTAL MATERIALS, 2014, 30 (04) :408-416
[4]  
Ferrari M, 2016, CLIN ORAL IMPLANT DE, DOI [10.1111/cid.12418, DOI 10.1111/CID.12418]
[5]   Failure analysis of fractured dental zirconia implants [J].
Gahlert, M. ;
Burtscher, D. ;
Grunert, I. ;
Kniha, H. ;
Steinhauser, E. .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (03) :287-293
[6]   Reliability and Failure Modes of Two Y-TZP Abutment Designs [J].
Mitsias, Miltiadis E. ;
Thompson, Van P. ;
Pines, Mitchel ;
Silva, Nelson R. F. A. .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (01) :75-78
[7]  
Mitsias ME, 2010, INT J PROSTHODONT, V23, P56
[8]   Titanium Tattooing Associated with Zirconia Implant Abutments: A Clinical Report of Two Cases [J].
Taylor, Thomas D. ;
Klotz, Michael W. ;
Lawton, Rodger A. .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (04) :958-960
[9]   Systematic Review of the Survival Rate and Incidence of Biologic, Technical, and Esthetic Complications of Single Implant Abutments Supporting Fixed Prostheses [J].
Zembic, Anja ;
Kim, Sunjai ;
Zwahlen, Marcel ;
Kelly, J. Robert .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 :99-116