Three-dimensional meniscus allograft sizing-a study of 280 healthy menisci

被引:17
作者
Beeler, Silvan [1 ]
Jud, Lukas [1 ]
von Atzigen, Marco [1 ]
Sutter, Reto [1 ]
Fuernstahl, Philipp [1 ]
Fucentese, Sandro F. [1 ]
Vlachopoulos, Lazaros [1 ]
机构
[1] Univ Zurich, Balgrist Univ Hosp, Dept Orthopaed, Forchstr 340, CH-8008 Zurich, Switzerland
关键词
ARTICULAR-CARTILAGE; CONTACT MECHANICS; RADIOGRAPHIC MEASUREMENT; TIBIAL PLATEAU; BONE-PLUG; TRANSPLANTATION; KNEE; SIZE; PRESSURE; SURVIVAL;
D O I
10.1186/s13018-020-01591-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Inaccurate meniscus allograft size is still an important problem of the currently used sizing methods. The purpose of this study was to evaluate a new three-dimensional (3D) meniscus-sizing method to increase the accuracy of the selected allografts. Methods: 3D triangular surface models were generated from 280 menisci based on 50 bilateral and 40 unilateral knee joint magnetic resonance imaging (MRI) scans. These models served as an imaginary meniscus allograft tissue bank. Meniscus sizing and allograft selection was simulated for all 50 bilateral knee joints by (1) the closest mean surface distance (MeSD) (3D-MRI sizing with contralateral meniscus), (2) the smallest meniscal width/length difference in MRI (2D-MRI sizing with contralateral meniscus), and (3) conventional radiography as proposed by Pollard (2D-radiograph (RX) sizing with ipsilateral tibia plateau). 3D shape and meniscal width, length, and height were compared between the original meniscus and the selected meniscus using the three sizing methods. Results: Allograft selection by MeSD (3D MRI) was superior for all measurement parameters. In particular, the 3D shape was significantly improved (p < 0.001), while the mean differences in meniscal width, length, and height were only slightly better than the allograft selected by the other methods. Outliers were reduced by up to 55% (vs. 2D MRI) and 83% (vs. 2D RX) for the medial meniscus and 39% (vs. 2D MRI) and 56% (vs. 2D RX) for the lateral meniscus. Conclusion: 3D-MRI sizing by MeSD using the contralateral meniscus as a reconstruction template can significantly improve meniscus allograft selection. Sizing using conventional radiography should probably not be recommended.
引用
收藏
页数:11
相关论文
共 46 条
[1]   Contact mechanics of the medial tibial plateau after implantation of a medial meniscal allograft - A human cadaveric study [J].
Alhalki, MM ;
Hull, ML ;
Howell, SM .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (03) :370-376
[2]  
Ambra LF, 2019, AM J SPORTS MED
[3]  
Beeler S, 2019, KNEE
[4]  
Cameron JC, 1997, CLIN ORTHOP RELAT R, P164
[5]  
COX JS, 1975, CLIN ORTHOP RELAT R, P178
[6]   Automatic segmentation of high-and low-field knee MRIs using knee image quantification with data from the osteoarthritis initiative [J].
Dam, Erik B. ;
Lillholm, Martin ;
Marques, Joselene ;
Nielsen, Mads .
JOURNAL OF MEDICAL IMAGING, 2015, 2 (02)
[7]   Effect of lateral meniscal allograft sizing on contact mechanics of the lateral tibial plateau - An experimental study in human cadaveric knee joints [J].
Dienst, Michael ;
Greis, Patrick E. ;
Ellis, Benjamin J. ;
Bachus, Kent N. ;
Burks, Robert T. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (01) :34-42
[8]   The sensitivity of tibiofemoral contact pressure to the size and shape of the lateral and medial menisci [J].
Donahue, TLH ;
Hull, ML ;
Rashid, MM ;
Jacobs, CR .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (04) :807-814
[9]   New algorithm for selecting meniscal allografts that best match the size and shape of the damaged meniscus [J].
Donahue, Tommy L. Haut ;
Hull, Maury L. ;
Howell, Stephen M. .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (07) :1535-1543
[10]   Meniscus allograft transplantation: indications, techniques and outcomes [J].
Figueroa, Francisco ;
Figueroa, David ;
Calvo, Rafael ;
Vaisman, Alex ;
Espregueira-Mendes, Joao .
EFORT OPEN REVIEWS, 2019, 4 (04) :115-120