Time-Resolved Microscopy for Imaging Lanthanide Luminescence in Living Cells

被引:73
作者
Gahlaut, Nivriti [1 ]
Miller, Lawrence W. [1 ]
机构
[1] Univ Illinois, Dept Chem, Chicago, IL 60607 USA
基金
美国国家卫生研究院;
关键词
fluorescence microscopy; lanthanide; time-resolved; signal-to-noise ratio; FLOW-CYTOMETRY; FLUORESCENCE MICROSCOPY; EUROPIUM NANOPARTICLES; CHELATE FLUORESCENCE; ENERGY-TRANSFER; VISIBLE-LIGHT; OSMOTIC LYSIS; IN-VITRO; TERBIUM; COMPLEXES;
D O I
10.1002/cyto.a.20964
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Time-resolved luminescence (TRL) microscopy can image signals from lanthanide coordination complexes or other probes with long emission lifetimes, thereby eliminating short-lifetime (<100 ns) autofluorescence background from biological specimens. However, lanthanide complexes emit far fewer photons per unit time than conventional fluorescent probes, making it difficult to rapidly acquire high quality images at probe concentrations that are relevant to live cell experiments. This article describes the development and characterization of a TRL microscope that employs a light-emitting diode (LED, lambda(em) = 365 nm) for pulsed epi-illumination and an intensified charge-coupled device (ICCD) camera for gated, widefield detection. Europium chelate-impregnated microspheres were used to evaluate instrument performance in terms of short-lifetime fluorescence background rejection, photon collection efficiency, image contrast, and signal-to-noise ratio (SNR). About 200 nm microspheres were imaged within the time resolution limit of the ICCD (66.7 ms) with complete autofluorescence suppression. About 40 nm microspheres containing similar to 400 chelate molecules were detected within similar to 1-s acquisition times. A luminescent terbium complex, Lumi4-Tb (R), was introduced into the cytoplasm of cultured cells at an estimated concentration of 300 nM by the method of osmotic lysis of pinocytic vesicles. Time-resolved images of the living, terbium complex-loaded cells were acquired within acquisition times as short as 333 ms, and the effects of increased exposure time and frame summing on image contrast and SNR were evaluated. The performance analyses show that TRL microscopy is sufficiently sensitive and precise to allow high-resolution, quantitative imaging of lanthanide luminescence in living cells under physiologically relevant experimental conditions. (C) 2010 International Society for Advancement of Cytometry
引用
收藏
页码:1113 / 1125
页数:13
相关论文
共 58 条
[1]   OCTACOORDINATE CHELATES OF LANTHANIDES . 2 SERIES OF COMPOUNDS [J].
BAUER, H ;
BLANC, J ;
ROSS, DL .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1964, 86 (23) :5125-+
[2]   Luminescence imaging microscopy and lifetime mapping using kinetically stable lanthanide(III) complexes [J].
Beeby, A ;
Botchway, SW ;
Clarkson, IM ;
Faulkner, S ;
Parker, AW ;
Parker, D ;
Williams, JAG .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2000, 57 (2-3) :83-89
[3]   PREPARATION AND MICROSCOPIC VISUALIZATION OF MULTICOLOR LUMINESCENT IMMUNOPHOSPHORS [J].
BEVERLOO, HB ;
VANSCHADEWIJK, A ;
BONNET, J ;
VANDERGEEST, R ;
RUNIA, R ;
VERWOERD, NP ;
VROLIJK, J ;
PLOEM, JS ;
TANKE, HJ .
CYTOMETRY, 1992, 13 (06) :561-570
[4]   INORGANIC PHOSPHORS AS NEW LUMINESCENT LABELS FOR IMMUNOCYTOCHEMISTRY AND TIME-RESOLVED MICROSCOPY [J].
BEVERLOO, HB ;
VANSCHADEWIJK, A ;
VANGELDERENBOELE, S ;
TANKE, HJ .
CYTOMETRY, 1990, 11 (07) :784-792
[5]  
Botchway SW, 2008, P NATL ACAD SCI USA, V105, P16071, DOI 10.1073/pnas.0804071105
[6]   Lanthanide Luminescence for Biomedical Analyses and Imaging [J].
Buenzli, Jean-Claude G. .
CHEMICAL REVIEWS, 2010, 110 (05) :2729-2755
[7]   TIME-RESOLVED FLOW-CYTOMETRY FOR THE MEASUREMENT OF LANTHANIDE CHELATE FLUORESCENCE .1. CONCEPT AND THEORETICAL EVALUATION [J].
CONDRAU, MA ;
SCHWENDENER, RA ;
NIEDERER, P ;
ANLIKER, M .
CYTOMETRY, 1994, 16 (03) :187-194
[8]   TIME-RESOLVED FLOW-CYTOMETRY FOR THE MEASUREMENT OF LANTHANIDE CHELATE FLUORESCENCE .2. INSTRUMENT DESIGN AND EXPERIMENTAL RESULTS [J].
CONDRAU, MA ;
SCHWENDENER, RA ;
ZIMMERMANN, M ;
MUSER, MH ;
GRAF, U ;
NIEDERER, P ;
ANLIKER, M .
CYTOMETRY, 1994, 16 (03) :195-205
[9]   High intensity solid-state UV source for time-gated luminescence microscopy [J].
Connally, Russell ;
Jin, Dayong ;
Piper, James .
CYTOMETRY PART A, 2006, 69A (09) :1020-1027
[10]   Time-gated luminescence microscopy [J].
Connally, Russell E. ;
Piper, James A. .
FLUORESCENCE METHODS AND APPLICATIONS: SPECTROSCOPY, IMAGING, AND PROBES, 2008, 1130 :106-116