Practical Considerations of Percutaneous Ventricular Assist Devices

被引:0
作者
Weiss, Sandra A. [1 ]
Jolly, Neeraj [1 ]
机构
[1] Univ Chicago, Med Ctr, Cardiol Sect, Chicago, IL 60637 USA
关键词
percutaneous left ventricular support; percutaneous left ventricular assist device; cardiogenic shock; high-risk percutaneous coronary intervention; INTRAAORTIC BALLOON COUNTERPULSATION; ACUTE MYOCARDIAL-INFARCTION; CARDIOGENIC-SHOCK; CORONARY INTERVENTION; HEART-FAILURE; RISK; SUPPORT; FEASIBILITY; SAFETY; TRIAL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Percutaneous ventricular assist devices are increasingly used today, allowing the scope of left ventricular support to move out of the operating room and into the interventional suite and cardiovascular care unit. This has given patients requiring short-term therapy an opportunity to undergo high-risk procedures and provide a failing left ventricular support until native recovery can occur. A growing body of evidence exists that demonstrates device efficacy and safety, as well as its potential clinical importance, a topic that will be reviewed here. Additionally, many providers seek a resource for technical considerations and troubleshooting. We also aim to provide insight into such considerations.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 39 条
[1]  
Antaki J, 2006, MECH CIRCULATORY SUP
[2]   Resuscitation and recovery from acute right ventricular failure using a percutaneous right ventricular assist device [J].
Atiemo, Andrew D. ;
Conte, John V. ;
Heldman, Alan W. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (01) :78-82
[3]  
BREGMAN D, 1980, T AM SOC ART INT ORG, V26, P8
[4]   A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shock [J].
Burkhoff, Daniel ;
Cohen, Howard ;
Brunckhorst, Corinna ;
O'Neill, William W. .
AMERICAN HEART JOURNAL, 2006, 152 (03) :469.e1-469.e8
[5]   Feasibility study of the use of the TandemHeart® percutaneous ventricular assist device for treatment of cardiogenic shock [J].
Burkhoff, Daniel ;
O'Neill, Williarn ;
Brunckhorst, Corinna ;
Letts, Dustin ;
Lasorda, David ;
Cohen, Howard A. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (02) :211-217
[6]   Feasibility and long-term safety of elective Impella-assisted high-risk percutaneous coronary intervention: a pilot two-centre study [J].
Burzotta, Francesco ;
Paloscia, Leonardo ;
Trani, Carlo ;
Mascellanti, Marco ;
Mongiardo, Rocco ;
Materazzo, Guido ;
Niccoli, Giampaolo ;
Di Marco, Massimo ;
Leone, Antonio Maria ;
Porto, Italo ;
Mazzari, Mario Attilio ;
Rebuzzi, Antonio Giuseppe ;
Schiavoni, Giovanni ;
Crea, Filippo .
JOURNAL OF CARDIOVASCULAR MEDICINE, 2008, 9 (10) :1004-1010
[7]   Percutaneous left ventricular assist devices vs. intra-aortic balloon pump counterpulsation for treatment of cardiogenic shock: a meta-analysis of controlled trials [J].
Cheng, Jin M. ;
den Uil, Corstiaan A. ;
Hoeks, Sanne E. ;
van der Ent, Martin ;
Jewbali, Lucia S. D. ;
van Domburg, Ron T. ;
Serruys, Patrick W. .
EUROPEAN HEART JOURNAL, 2009, 30 (17) :2102-2108
[9]   A Prospective Feasibility Trial Investigating the Use of the Impel la 2.5 System in Patients Undergoing High-Risk Percutaneous Coronary Intervention (The PROTECT I Trial) Initial US Experience [J].
Dixon, Simon R. ;
Henriques, Jose P. S. ;
Mauri, Laura ;
Sjauw, Krischan ;
Civitello, Andrew ;
Kar, Biswajit ;
Loyalka, Pranav ;
Resnic, Frederic S. ;
Teirstein, Paul ;
Makkar, Raj ;
Palacios, Igor F. ;
Collins, Michael ;
Moses, Jeffrey ;
Benali, Karim ;
O'Neill, William W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (02) :91-96
[10]  
Goldstein D, 2006, MECH CIRCULATORY SUP