In-vivo validation of fluorescence lifetime imaging (FLIm) of coronary arteries in swine

被引:1
|
作者
Bec, Julien [1 ]
Ma, Dinglong [1 ]
Yankelevitch, Diego R. [1 ]
Gorpas, Dimitris [1 ]
Ferrier, William T. [2 ]
Southard, Jeffrey [3 ]
Marcu, Laura [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Univ Calif Davis, Sch Med, Surg Res Facil, Davis, CA 95616 USA
[3] Univ Calif Davis, Med Ctr, Div Cardiovasc Med, Davis, CA 95817 USA
来源
PHOTONIC THERAPEUTICS AND DIAGNOSTICS XI | 2015年 / 9303卷
关键词
time resolved fluorescence spectroscopy; fluorescence lifetime imaging; intravascular catheter atherosclerosis;
D O I
10.1117/12.2079833
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We report a scanning imaging system that enables high speed multispectral fluorescence lifetime imaging (FLIm) of coronary arteries. This system combines a custom low profile (3 Fr) imaging catheter using a 200 mu m core side viewing UV-grade silica fiber optic, an acquisition system able to measure fluorescence decays over four spectral bands at 20 kHz and a fast data analysis and display module. In vivo use of the system has been optimized, with particular emphasis on clearing blood from the optical pathway. A short acquisition time (5 seconds for a 20 mm long coronary segment) enabled data acquisition during a bolus saline solution injection through the 7 Fr catheter guide. The injection parameters were precisely controlled using a power injector and optimized to provide good image quality while limiting the bolus injection duration and volume (12 cc/s, 80 cc total volume). The ability of the system to acquire data in vivo was validated in healthy swine by imaging different sections of the left anterior descending (LAD) coronary. A stent coated with fluorescent markers was placed in the LAD and imaged, demonstrating the ability of the system to discriminate in vivo different fluorescent features and structures from the vessel background fluorescence using spectral and lifetime information. Intensity en face images over the four bands of the instrument were available within seconds whereas lifetime images were computed in 2 minutes, providing efficient feedback during the procedure. This successful demonstration of FLIm in coronaries enables future study of atherosclerotic cardiovascular diseases.
引用
收藏
页数:5
相关论文
共 32 条
  • [31] Changes in the redox state and endogenous fluorescence of in vivo human skin due to intrinsic and photo-aging, measured by multiphoton tomography with fluorescence lifetime imaging (vol 18, 061217, 2013)
    Sanchez, Washington Y.
    Obispo, Clara
    Ryan, Elizabeth
    Grice, Jeffrey E.
    Roberts, Michael S.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (06)
  • [32] Multispectral label-free in vivo cellular imaging of human retinal pigment epithelium using adaptive optics fluorescence lifetime ophthalmoscopy improves feasibility for low emission analysis and increases sensitivity for detecting changes with age and eccentricity
    Kunala, Karteek
    Tang, Janet A. H.
    Parkins, Keith
    Hunter, Jennifer J.
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29 : S22707