Lumbar vertebra morphometry and stereological assesment of intervertebral space volumetry: A methodological study

被引:17
作者
Karabekir, Hamit S. [1 ]
Gocmen-Mas, Nuket [2 ]
Edizer, Mete [3 ]
Ertekin, Tolga [4 ]
Yazici, Canan [5 ]
Atamturk, Derya [6 ]
机构
[1] Afyon Kocatepe Univ, Sch Med, Dept Neurosurg, Afyon, Turkey
[2] Afyon Kocatepe Univ, Sch Med, Dept Anat, Afyon, Turkey
[3] Ondokuz Mayis Univ, Sch Med, Dept Anat, Samsun, Turkey
[4] Erciyes Univ, Sch Med, Dept Anat, Kayseri, Turkey
[5] Baskent Univ, Sch Med, Dept Biostat, TR-06490 Ankara, Turkey
[6] Gaziantep Univ, Fac Arts & Sci, Dept Archaeol, Gaziantep, Turkey
关键词
Neurosurgery; Morphometry; Dry lumbar vertebrae; Pedicle; Intervertebral space; Posterior fixation technique; Stereology; PEDICLE SCREW FIXATION; FRACTURES;
D O I
10.1016/j.aanat.2011.01.011
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The use of technology in the treatment of degenerative spinal diseases has undergone rapid clinical and scientific development. It has been extensively studied in combination with various techniques for spinal stabilization from both the anterior and posterior approach. Minimally invasive and instrumental approach via posterior fixation is increasingly being used for the treatment of adult degenerative disc disease, stenosis, and deformity of the lumbar vertebrae. Posterior access to the lumbar disc spaces for posterolateral fusion scan has been technically challenging, frequently requiring the use of an approach surgery for adequate exposure. For successful surgery and suitable instrumental design, adequate anatomical knowledge of the lumbar vertebra is also needed. Anatomic features of lumbar vertebrae are of importance for posterior screw fixation technique. The morphometry of L1-L5 has been studied to facilitate the safe application of pedicle screws. Thus, we aimed to evaluate the morphometric landmarks of lumbar vertebrae such as pedicle, vertebral body, vertebral foramen, intervertebral space height and volume for safe surgical intervention using a posterior fixation approach to offer anatomical supports for lumbar discectomy, stenosis and cases of deformity. The features of the L1-L5 vertebral body, the detailed morphometric parameters of lumbar vertebrae and the intervertebral space were analyzed using computerized tomography scan, magnetic resonance imaging and also dry lumbar vertebrae. Additionally, intervertebral space volumes were measured using stereological methods to ensure safe surgical intervention. (C) 2011 Elsevier GmbH. All rights reserved.
引用
收藏
页码:231 / 236
页数:6
相关论文
共 27 条
[1]   New method for intraoperative determination of proper screw insertion or screw malposition [J].
Açikbas, SC ;
Tuncer, MR .
JOURNAL OF NEUROSURGERY, 2000, 93 (01) :40-44
[2]   Short segment pedicle screw instrumentation and augmentation vertebroplasty in lumbar burst fractures: an experience [J].
Afzal, Suhail ;
Akbar, Saleem ;
Dhar, Shabir A. .
EUROPEAN SPINE JOURNAL, 2008, 17 (03) :336-341
[3]   Posterior vertebrectomy in kyphosis, scoliosis and kyphoscoliosis due to hemivertebra [J].
Aydogan, Mehmet ;
Ozturk, Cagatay ;
Tezer, Mehmet ;
Mirzanli, Cuneyt ;
Karatoprak, Omer ;
Hamzaoglu, Azmi .
JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2008, 17 (01) :33-37
[4]   A COMPARISON OF FLUOROSCOPY AND COMPUTED TOMOGRAPHY-DERIVED VOLUMETRIC MULTIPLE EXPOSURE TRANSMISSION HOLOGRAPHY FOR THE GUIDANCE OF LUMBAR PEDICLE SCREW INSERTION [J].
BENZEL, EC ;
RUPP, FW ;
MCCORMACK, BM ;
BALDWIN, NG ;
ANSON, JA ;
ADAMS, MS .
NEUROSURGERY, 1995, 37 (04) :711-716
[5]  
Boachie-Adjei Oheneba, 2007, HSS J, V3, P93, DOI 10.1007/s11420-006-9038-8
[6]  
Boos N., 1994, EUR SPINE J, V6, P1
[7]   Biomechanical investigation of pedicle screw-vertebrae complex: a finite element approach using bonded and contact interface conditions [J].
Chen, SI ;
Lin, RM ;
Chang, CH .
MEDICAL ENGINEERING & PHYSICS, 2003, 25 (04) :275-282
[8]   INDICATIONS FOR PEDICLE FIXATION - RESULTS OF NASS/SRS FACULTY QUESTIONNAIRE [J].
CRAWFORD, MJ ;
ESSES, SI .
SPINE, 1994, 19 (22) :2584-2589
[9]   A NEW DEVICE FOR INTERNAL-FIXATION OF THORACOLUMBAR AND LUMBAR SPINE FRACTURES - THE FIXATEUR-INTERNE [J].
DICK, W ;
KLUGER, P ;
MAGERL, F ;
WOERSDORFER, O ;
ZACH, G .
PARAPLEGIA, 1985, 23 (04) :225-232
[10]   COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS [J].
ESSES, SI ;
SACHS, BL ;
DREYZIN, V .
SPINE, 1993, 18 (15) :2231-2239