Qualitative and quantitative comparison of heat separated epidermis and dermatomed skin in percutaneous absorption studies

被引:20
作者
Atrux-Tallau, Nicolas
Pirot, Fabrice
Falson, Francoise
Roberts, Michael S.
Maibach, Howard I.
机构
[1] Univ Lyon 1, Fac Pharm, Lab Rech & Dev Pharm Galen Ind, EA 4169,Fonct Normales & Pathol Barriere Cutanee, F-69373 Lyon 08, France
[2] Univ Queensland, Princess Alexandra Hosp, So Clin Div, Therapeut Res Inst, Brisbane, Qld 4102, Australia
[3] Univ Calif San Francisco, Dept Dermatol, San Francisco, CA 94142 USA
关键词
heat separated epidermis; dermatomed skin; caffeine; transepidermal water loss; skin permeability;
D O I
10.1007/s00403-007-0789-y
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Transepidermal water loss (TEWL), mainly regulated by the stratum corneum, was quantitatively correlated to percutaneous absorption of compounds in human and suggested for the ex vivo assessment of skin integrity. The present study investigated qualitatively and quantitatively the relevance of 100-mu m heat separated epidermis (HSE) in percutaneous absorption studies as compared to 500-mu m dermatomed skin by dual complementary approaches. Percutaneous absorption of caffeine delivered from aqueous solution through dermatomed skin or HSE specimens (n = 9) was measured using vertical static diffusion cells coupled with an unventilated evaporimeter enabling the assessment of TEWL and skin integrity for 21 h. Permeation of caffeine exhibited different finite dose-like profiles ranged according to the thickness of skin specimens (cumulative dose absorbed up to 21 h: 11.5 +/- 11.5 mu g/cm(2) and 29.4 +/- 36.2 mu g/cm(2) through dermatomed skin and HSE, respectively). Normalized TEWL and caffeine fluxes were similar through dermatomed skin and HSE suggesting that the intrinsic permeability properties of both models were undifferentiated over time. Interestingly, a significant relationship was shown between TEWL and caffeine fluxes, suggesting the usefulness of TEWL measurement as an element in the estimation of percutaneous drug absorption. In conclusion, the present showed that percutaneous absorption through HSE was qualitatively and quantitatively similar to dermatomed skin when TEWL as endogenous standard and skin thickness were considered in permeability data comparisons.
引用
收藏
页码:507 / 511
页数:5
相关论文
共 16 条
[1]  
COLLIER SW, 1991, IN VITRO PERCUTANEOU, P157
[2]   STRATUM-CORNEUM LIPIDS SERVE AS A BOUND-WATER MODULATOR [J].
IMOKAWA, G ;
KUNO, H ;
KAWAI, M .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1991, 96 (06) :845-851
[3]   The correlation between transepidermal water loss and percutaneous absorption: An overview [J].
Levin, J ;
Maibach, H .
JOURNAL OF CONTROLLED RELEASE, 2005, 103 (02) :291-299
[4]   In vitro measurement of transepidermal water loss: A rapid alternative to tritiated water permeation for assessing skill barrier functions [J].
Nangia, A ;
Patil, S ;
Berner, B ;
Boman, A ;
Maibach, H .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1998, 170 (01) :33-40
[5]  
NANGIA A, 1999, PERCUTANEOUS ABSORPT, P587
[6]   TEWL measurements as a routine method for evaluating the integrity of epidermis sheets in static Franz type diffusion cells in vitro. Limitations shown by transport data testing [J].
Netzlaff, F ;
Kostka, KH ;
Lehr, CM ;
Schaefer, UF .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2006, 63 (01) :44-50
[7]  
Organisation for Economic Co-operation and Development (OECD) Guidance document for the conduct of skin absorption studies, 2004, OECD SER TEST ASS, P31
[8]   Characterization of the permeability barrier of human skin in vivo [J].
Pirot, F ;
Kalia, YN ;
Stinchcomb, AL ;
Keating, G ;
Bunge, A ;
Guy, RH .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (04) :1562-1567
[9]   Stratum corneum thickness and apparent water diffusivity:: Facile and noninvasive quantitation in vivo [J].
Pirot, F ;
Berardesca, E ;
Kalia, YN ;
Singh, M ;
Maibach, HI ;
Guy, RH .
PHARMACEUTICAL RESEARCH, 1998, 15 (03) :492-494
[10]   The middle cardiac vein - A novel pathway to reduce the defibrillation threshold [J].
Roberts, PR ;
Urban, JF ;
Euler, DE ;
Kallok, MJ ;
Morgan, JM .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1999, 3 (01) :55-60