International Classification of Reliability for Implanted Cochlear Implant Receiver Stimulators

被引:35
|
作者
Battmer, Rolf-Dieter [2 ]
Backous, Douglas D. [1 ]
Balkany, Thomas J. [3 ]
Briggs, Robert J. S. [4 ]
Gantz, Bruce J. [5 ]
van Hasselt, Andrew [6 ]
Kim, Chong Sun [7 ]
Kubo, Takeshi [8 ]
Lenarz, Thomas [9 ]
Pillsbury, Harold C., III [10 ]
O'Donoghue, Gerard M. [11 ]
机构
[1] Virginia Mason Med Ctr, Listen Life Ctr Virginia Mason, Sect Otolaryngol Head & Neck Surg, Seattle, WA 98101 USA
[2] Ctr Clin Technol Res, Berlin, Germany
[3] Univ Miami, Ear Inst, Dept Otolaryngol, Miami, FL USA
[4] Royal Victorian Eye & Ear Hosp, Otol Unit, Melbourne, Vic 3002, Australia
[5] Univ Iowa, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
[6] Chinese Univ Hong Kong, Dept Otorhinolaryngol Head & Neck Surg, Hong Kong, Hong Kong, Peoples R China
[7] Seoul Natl Univ, Bundang Hosp, Dept Otolaryngol, Seoul, South Korea
[8] Osaka Univ, Sch Med, Dept Otorhinolaryngol, Osaka, Japan
[9] Hannover Med Sch, Dept Otolaryngol, Hannover, Germany
[10] Univ N Carolina, Dept Otolaryngol Head & Neck Surg, Chapel Hill, NC USA
[11] Univ Hosp NHS Trust, Dept Otolaryngol, Nottingham, England
关键词
Cochlear implant; Device failure; Reliability; Reporting standard;
D O I
10.1097/MAO.0b013e3181d2798e
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To design an international standard to be used when reporting reliability of the implanted components of cochlear implant systems to appropriate governmental authorities, cochlear implant (CI) centers, and for journal editors in evaluating manuscripts involving cochlear implant reliability. Study Design: The International Consensus Group for Cochlear Implant Reliability Reporting was assembled to unify ongoing efforts in the United States, Europe, Asia, and Australia to create a consistent and comprehensive classification system for the implanted components of CI systems across manufacturers. Setting: All members of the consensus group are from tertiary referral cochlear implant centers. Interventions: None. Main Outcome Measure: A clinically relevant classification scheme adapted from principles of ISO standard 5841-2: 2000 (1) originally designed for reporting reliability of cardiac pacemakers, pulse generators, or leads. Results: Standard definitions for device failure, survival time, clinical benefit, reduced clinical benefit, and specification were generated. Time intervals for reporting back to implant centers for devices tested to be Bout of specification," categorization of explanted devices, the method of cumulative survival reporting, and content of reliability reports to be issued by manufacturers was agreed upon by all members. The methodology for calculating Cumulative survival was adapted from ISO standard 5841-2: 2000 (1). Conclusion: The International Consensus Group on Cochlear Implant Device Reliability Reporting recommends compliance to this new standard in reporting reliability of implanted CI components by all manufacturers of CIs and the adoption of this standard as a minimal reporting guideline for editors of journals publishing cochlear implant research results.
引用
收藏
页码:1190 / 1193
页数:4
相关论文
共 50 条
  • [21] Automatic Classification of Cochlear Implant Electrode Cavity Positioning
    Noble, Jack H.
    Labadie, Robert F.
    Dawant, Benoit M.
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT IV, 2018, 11073 : 47 - 54
  • [22] Reliability of Measuring Insertion Depth in Cochlear Implanted Infants and Children Using Cochlear View Radiography
    Noble, Anisha R.
    Christianson, Erin
    Norton, Susan J.
    Ou, Henry C.
    Phillips, Grace S.
    Khalatbari, Hedieh
    Friedman, Seth D.
    Horn, David L.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2020, 163 (04) : 822 - 828
  • [23] Early Hearing Outcomes and Audiological Experiences With a Novel Fully Implanted Cochlear Implant
    Dornhoffer, James R.
    DeJong, Melissa D.
    Driscoll, Colin L. W.
    Saoji, Aniket A.
    OTOLOGY & NEUROTOLOGY, 2024, 45 (10) : e727 - e734
  • [24] Speech Perception Comparisons Using an Implanted and an External Microphone in Existing Cochlear Implant Users
    Jenkins, Herman A.
    Uhler, Kristin
    OTOLOGY & NEUROTOLOGY, 2012, 33 (01) : 13 - 19
  • [25] Cochlear Implant Outcomes: Quality of Life in Prelingually Deafened, Late-Implanted Patients
    Rizkou, Fatima Ezzahra
    Benhoummad, Othmane
    Rochd, Sara
    Lakhdar, Youssef
    Rochdi, Youssef
    Raji, Abdelaziz
    OTOLOGY & NEUROTOLOGY, 2024, 45 (01) : E24 - E27
  • [26] Development of a chronically-implanted mouse model for studies of cochlear health and implant function
    Colesa, Deborah J.
    Devare, Jenna
    Swiderski, Donald L.
    Beyer, Lisa A.
    Raphael, Yehoash
    Pfingst, Bryan E.
    HEARING RESEARCH, 2021, 404
  • [27] Speech perception results for children implanted with the CLARION® cochlear implant at the Medical University of Hannover
    Illg, A
    von der Haar-Heise, S
    Goldring, JE
    Lesinski-Schiedat, A
    Battmer, RD
    Lenarz, T
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1999, 108 (04) : 93 - 98
  • [28] Positioning of the receiver-stimulator for the CI-24M cochlear implant in infants
    Mitchell, TE
    Gibson, WPR
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1999, 113 (03) : 212 - 216
  • [29] SAS-CIS preference study in postlingually deafened adults implanted with the CLARION® cochlear implant
    Osberger, MJ
    Fisher, L
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1999, 108 (04) : 74 - 79
  • [30] Delayed Auditory Brainstem Responses in Prelingually Deaf and Late-Implanted Cochlear Implant Users
    Marc J. W. Lammers
    Ruben H. M. van Eijl
    Gijsbert A. van Zanten
    Huib Versnel
    Wilko Grolman
    Journal of the Association for Research in Otolaryngology, 2015, 16 : 669 - 678