The effect of surface composition of titanium films on bacterial adhesion

被引:19
作者
Jeyachandran, Y. L. [1 ]
Narayandass, Sa K.
Mangalaraj, D.
Bao, C. Y.
Martin, P. J.
机构
[1] Bharathiar Univ, Dept Phys, Coimbatore 641046, Tamil Nadu, India
[2] Sichuan Univ, W China Coll Stomatol, Chengdu 610041, Peoples R China
[3] CSIRO Ind Phys, Lindfield, NSW 2070, Australia
关键词
D O I
10.1088/1748-6041/1/1/L01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We show that bacterial adhesion on titanium (Ti) films could be radically minimized by tailoring the surface chemical stoichiometry of the films. Using a dc magnetron sputtering system, Ti films with various surface compositions, such as oxide and nitride combinations, were prepared by controlling processing parameters such as cathode power, sputtering pressure and base vacuum. The surface topography of the films was observed to be smooth and similar in all the films prepared under different conditions. The order of adhesion of the oral bacterial Porphyromonas gingivalis varied with the surface chemical stoichiometry of the Ti films. Few surface stoichiometries of typical oxide nitride combination resulted in nearly nil bacterial adhesion.
引用
收藏
页码:L1 / L5
页数:5
相关论文
共 12 条
[1]  
BOLZ A, 1993, MED BIOL ENG COMPUT, V31, P123
[2]   AN ELECTROCHEMICAL METHOD FOR ASSESSING BIODEPOSITION ON STAINLESS-STEEL [J].
BOULANGEPETERMANN, L ;
BELLONFONTAINE, MN ;
BAROUX, B .
JOURNAL OF MICROBIOLOGICAL METHODS, 1995, 21 (01) :83-96
[3]   Surface structure and composition of flat titanium thin films as a function of film thickness and evaporation rate [J].
Cai, KY ;
Müller, M ;
Bossert, J ;
Rechtenbach, A ;
Jandt, KD .
APPLIED SURFACE SCIENCE, 2005, 250 (1-4) :252-267
[4]   Ti4+ to Ti3+ conversion of TiO2 uppermost layer by low-temperature vacuum annealing:: Interest for titanium biomedical applications [J].
Guillemot, F ;
Porté, MC ;
Labrugère, C ;
Baquey, C .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2002, 255 (01) :75-78
[5]   Bacterial biofilms: From the natural environment to infectious diseases [J].
Hall-Stoodley, L ;
Costerton, JW ;
Stoodley, P .
NATURE REVIEWS MICROBIOLOGY, 2004, 2 (02) :95-108
[6]   Staphylococcus aureus adhesion to titanium oxide surfaces coated with non-functionalized and peptide-functionalized poly(L-lysine)-grafted-poly(ethylene glycol) copolymers [J].
Harris, LG ;
Tosatti, S ;
Wieland, M ;
Textor, M ;
Richards, RG .
BIOMATERIALS, 2004, 25 (18) :4135-4148
[7]   Bacterial adhesion to titanium-oxy-nitride (TiNOX) coatings with different resistivities: a novel approach for the development of biomaterials [J].
Koerner, RJ ;
Butterworth, LA ;
Mayer, IV ;
Dasbach, R ;
Busscher, HJ .
BIOMATERIALS, 2002, 23 (14) :2835-2840
[8]   Measurement of charge transfer during bacterial adhesion to an indium tin oxide surface in a parallel plate flow chamber [J].
Poortinga, AT ;
Bos, R ;
Busscher, HJ .
JOURNAL OF MICROBIOLOGICAL METHODS, 1999, 38 (03) :183-189
[9]   AN ELECTROCHEMICAL STUDY OF THE EFFECT OF TEMPERATURE ON THE ADSORPTION BEHAVIOR OF BETA-LACTOGLOBULIN [J].
ROSCOE, SG ;
FULLER, KL ;
ROBITAILLE, G .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1993, 160 (01) :243-251
[10]   Inhibiting bacterial adhesion onto surfaces: the non-stick coating approach [J].
Tsibouklis, J ;
Stone, M ;
Thorpe, AA ;
Graham, P ;
Nevell, TG ;
Ewen, RJ .
INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2000, 20 (02) :91-96