A medium-term comparison of hybrid hip replacement and Birmingham hip resurfacing in active young patients

被引:41
作者
Baker, R. P. [1 ]
Pollard, T. C. B. [2 ]
Eastaugh-Waring, S. J. [1 ]
Bannister, G. C. [1 ]
机构
[1] Southmead Gen Hosp, Avon Orthopaed Ctr, Bristol BS10 5NB, Avon, England
[2] Univ Oxford, Nuffield Orthopaed Ctr, Oxford OX3 7LD, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2011年 / 93B卷 / 02期
关键词
RANDOMIZED-CLINICAL-TRIAL; FOLLOW-UP; PRIMARY OSTEOARTHRITIS; ARTHROPLASTY REGISTER; ACETABULAR COMPONENT; AGE; MINIMUM; POLYETHYLENE; CHARNLEY; SOCKETS;
D O I
10.1302/0301-620X.93B2.25625
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the medium-term clinical and radiological results of hybrid total hip replacement (THR) with metal-on-metal Birmingham hip resurfacing (BHR) in two groups of 54 young patients matched for age, gender, body mass index and pre-operative levels of activity. The clinical outcome was assessed by the University of California, Los Angeles (UCLA) activity score, the Oxford Hip Score (OHS) and the EuroQol scores. Radiologically, all hips were assessed for migration and osteolysis, the hybrid THRs for polyethylene wear and the BHRs for a pedestal sign. The mean follow-up of the patients with a hybrid THR was ten years and for those with a BHR, nine years. Four patients with a hybrid THR and one with a BHR had died. In each group five were lost to follow-up. The revision rate of the hybrid THRs was 16.7% (9 of 54) and of the BHRs 9.3% (5 of 54) (p = 0.195). Radiographs of a further eight hybrid THRs demonstrated wear and osteolysis, and they await revision (p = 0.008). Of the unrevised BHRs 90% had radiological changes, of which approximately 50% had progressed over the previous four years. All hybrid THRs demonstrated linear polyethylene wear with a mean of 1.24 mm (0.06 to 3.03). The BHRs recorded superior OHS (p = 0.013), UCLA (p = 0.008), and EuroQol visual analogue scores (p = 0.009). After nine years, patients with BHRs remained more active and had a lower rate of revision than those with hybrid THRs. Both groups demonstrated progressive radiological changes at medium-term follow-up.
引用
收藏
页码:158 / 163
页数:6
相关论文
共 36 条
[1]   Hip Resurfacing Results for Osteonecrosis Are as Good as for Other Etiologies at 2 to 12 Years [J].
Amstutz, Harlan C. ;
Le Duff, Michel J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) :375-381
[2]   TREATMENT OF PRIMARY OSTEOARTHRITIS OF THE HIP - A COMPARISON OF TOTAL JOINT AND SURFACE REPLACEMENT ARTHROPLASTY [J].
AMSTUTZ, HC ;
THOMAS, BJ ;
JINNAH, R ;
KIM, W ;
GROGAN, T ;
YALE, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (02) :228-241
[3]   Metal-on-metal hybrid surface arthroplasty:: Two to six-year follow-up study [J].
Amstutz, HC ;
Beaulé, PE ;
Dorey, FJ ;
Le Duff, MJ ;
Campbell, PA ;
Gruen, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) :28-39
[4]  
[Anonymous], 2009, 6 NAT JOINT REG ENGL
[5]   EuroQol: The current state of play [J].
Brooks, R .
HEALTH POLICY, 1996, 37 (01) :53-72
[6]   Cemented Polished Tapered Stems in Patients Less Than 50 Years of Age: A Minimum 10-year Follow-Up [J].
Burston, Ben J. ;
Yates, Piers J. ;
Hook, Samantha ;
Moulder, Elizabeth ;
Whitley, Elise ;
Bannister, Gordon C. .
JOURNAL OF ARTHROPLASTY, 2010, 25 (05) :692-699
[7]  
Curry H G, 2008, J Orthop Surg (Hong Kong), V16, P201
[8]   Ten-year results of a double-heat-treated metal-on-metal hip resurfacing [J].
Daniel, J. ;
Ziaee, H. ;
Kamali, A. ;
Pradhan, C. ;
Band, T. ;
McMinn, D. J. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (01) :20-27
[9]   Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis [J].
Daniel, J ;
Pynsent, PB ;
McMinn, DJW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (02) :177-184
[10]   Comparison of measures to assess outcomes in total hip replacement surgery [J].
Dawson, J ;
Fitzpatrick, R ;
Murray, D ;
Carr, A .
QUALITY IN HEALTH CARE, 1996, 5 (02) :81-88