When deriving the spatial QRS-T angle from the 12-lead electrocardiogram, which transform is more Frank: regression or inverse Dower?

被引:59
作者
Cortez, Daniel L. [1 ,2 ,3 ,4 ]
Schlegel, Todd T. [1 ]
机构
[1] NASA, Lyndon B Johnson Space Ctr, Houston, TX 77058 USA
[2] Univ Illinois, Coll Med, Champaign, IL 61820 USA
[3] Univ Illinois, Coll Med, Rockford, IL 61107 USA
[4] Natl Space Biomed Res Inst, Houston, TX USA
关键词
Vectorcardiography; Spatial ventricular gradient; 3-Dimensional ECG; Lead reconstruction; LEFT-VENTRICULAR HYPERTROPHY; CORONARY-ARTERY-DISEASE; PREDICTS CARDIAC DEATH; POSTMENOPAUSAL WOMEN; HEART-FAILURE; VECTORCARDIOGRAM; MORTALITY; REPOLARIZATION; ISCHEMIA; MEN;
D O I
10.1016/j.jelectrocard.2010.03.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Our primary objective was to ascertain which commonly used 12-to-Frank-lead transformation yields spatial QRS-T angle values closest to those obtained from simultaneously collected true Frank-lead recordings. Materials and Methods: Simultaneous 12-lead and Frank XYZ-lead recordings were analyzed for 100 postmyocardial infarction patients and 50 controls. Relative agreement, with true Frank-lead results, of 12-to-Frank-lead-transformed results for the spatial QRS-T angle using Kors' regression versus inverse Dower was assessed via analysis of variance, Lin's concordance, and Bland-Altman plots. Results: Spatial QRS-T angles from the true Frank leads were not significantly different than those derived from the Kors' regression-related transformation but were significantly smaller than those derived from the inverse Dower-related transformation (P < .001). Independent of method, spatial mean QRS-T angles were also always significantly larger than spatial "maximum" ("peaks") QRS-T angles. Discussion: Spatial QRS-T angles are best approximated by regression-related transforms. Spatial mean and spatial "peaks" QRS-T angles should not be used interchangeably. Published by Elsevier Inc.
引用
收藏
页码:302 / 309
页数:8
相关论文
共 35 条
[11]   MEAN QRS, VENTRICULAR GRADIENT AND LEFT-VENTRICULAR MASS IN PATIENTS WITH ECCENTRIC LEFT-VENTRICULAR HYPERTROPHY [J].
ISHIZAWA, K .
JOURNAL OF ELECTROCARDIOLOGY, 1975, 8 (03) :227-232
[12]   VECTORCARDIOGRAPHIC FINDINGS IN CONCENTRIC AND ECCENTRIC LEFT-VENTRICULAR HYPERTROPHY AS DETERMINED BY ANGIOCARDIOGRAMS .1. PRELIMINARY REPORT [J].
ISHIZAWA, K ;
MURAI, K ;
MOTOMURA, M ;
MATSUOKA, J ;
CHEN, CH ;
SAKURAI, T ;
WAKABAYASHI, A ;
NOHARA, Y ;
YAGINUMA, T .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1975, 39 (03) :247-256
[13]   HIGH RELIABILITY RATES OF SPATIAL PATTERN-ANALYSIS BY VECTORCARDIOGRAM IN ASSESSING SEVERITY OF ECCENTRIC LEFT-VENTRICULAR HYPERTROPHY [J].
ISHIZAWA, K ;
ISHIZAWA, K ;
MOTOMURA, M ;
KONISHI, T ;
WAKABAYASHI, A ;
ISHIKAWA, K ;
NOHARA, Y ;
KAWAI, C ;
KOIE, H .
AMERICAN HEART JOURNAL, 1976, 91 (01) :50-57
[14]  
JEFFREYS H, 1988, NUMERICAL METHODS ME, P286
[15]   Spatial QRS-T angle predicts cardiac death in a general population [J].
Kardys, I ;
Kors, JA ;
van der Meer, IM ;
Hofman, A ;
van der Kuip, DAM ;
Witteman, JCM .
EUROPEAN HEART JOURNAL, 2003, 24 (14) :1357-1364
[16]   Spatial QRS-T angle as a risk indicator of cardiac death in an elderly population [J].
Kors, JA ;
Kardys, I ;
van der Meer, IM ;
van Herpen, G ;
Hofman, A ;
van der Kuip, DAM ;
Witteman, JCM .
JOURNAL OF ELECTROCARDIOLOGY, 2003, 36 :113-114
[17]   RECONSTRUCTION OF THE FRANK VECTORCARDIOGRAM FROM STANDARD ELECTROCARDIOGRAPHIC LEADS - DIAGNOSTIC COMPARISON OF DIFFERENT METHODS [J].
KORS, JA ;
VANHERPEN, G ;
SITTIG, AC ;
VANBEMMEL, JH .
EUROPEAN HEART JOURNAL, 1990, 11 (12) :1083-1092
[18]   ORTHOGONAL ELECTROCARDIOGRAM DERIVED FROM THE LIMB AND CHEST ELECTRODES OF THE CONVENTIONAL 12-LEAD SYSTEM [J].
LEVKOV, CL .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1987, 25 (02) :155-164
[19]   SPATIAL PATTERNS OF VENTRICULAR REPOLARIZATION IN ARTERIAL HYPERTENSION [J].
LIBRETTI, A ;
ZANCHETTI, A .
AMERICAN HEART JOURNAL, 1960, 59 (01) :40-52
[20]   A CONCORDANCE CORRELATION-COEFFICIENT TO EVALUATE REPRODUCIBILITY [J].
LIN, LI .
BIOMETRICS, 1989, 45 (01) :255-268