Determination of Prostate Volume: A Comparison of Contemporary Methods

被引:48
作者
Bezinque, Adam [1 ]
Moriarity, Andrew [2 ,3 ]
Farrell, Crystal [2 ,4 ]
Peabody, Henry [2 ]
Noyes, Sabrina L. [2 ]
Lane, Brian R. [2 ,5 ]
机构
[1] Michigan State Univ, Coll Osteopath Med, E Lansing, MI 48824 USA
[2] Spectrum Hlth, 145 Michigan St NE, Grand Rapids, MI 49503 USA
[3] Adv Radiol Serv PC, Grand Rapids, MI USA
[4] Grand Rapids Med Educ Partners, Grand Rapids, MI USA
[5] Michigan State Univ, Coll Human Med, 145 Michigan St NE, Grand Rapids, MI 49503 USA
关键词
Prostate cancer; magnetic resonance imaging; prostate volume; TRUS; DIGITAL RECTAL EXAMINATION; MAGNETIC-RESONANCE; TRANSRECTAL ULTRASOUND; ACTIVE SURVEILLANCE; RISK; SEGMENTATION; MRI; SHAPE;
D O I
10.1016/j.acra.2018.03.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Prostate volume (PV) determination provides important clinical information. We compared PVs determined by digital rectal examination (DRE), transrectal ultrasound (TRUS), magnetic resonance imaging (MRI) with or without three-dimensional (3D) segmentation software, and surgical prostatectomy weight (SPVV) and volume (SPV). Materials and Methods: This retrospective review from 2010 to 2016 included patients who underwent radical prostatectomy <= 1 year after multiparametric prostate MRI. PVs from ORE and TAUS were obtained from urology clinie notes: MRI based PVs were calculatcd using bullet and ellipsoid formulas, automated 3D segmentation software (MRI-A3D), manual segmentation by a radiologist (MRI-R3D), and a third-year medical student (MRI-S3D). SPW and SPV were derived from pathology reports. Intraclass correlation coefficients compared the relative accuracy of each volume measurement. Results: Ninety-nine patients were analyzed. Median PVs were DRE 35 mL, TRUS 35 mL, MRI-bullet 49 mL, MRI-ellipsoid 39 mL, MRI-A3D 37 mL, MRI-R3D 36 mL, MRI-S3D 36 mL, SPW 54 mL, SPV-bullet 47 mL, and SPV-ellipsoid 37 mL. SPW and bullet formulas had consistently large PV, and formula-based PV had a wider spread than PV based on segmentation. Compared to MRI-R3D, the intraclass correlation coefficient was 0.91 for MRI-S3D, 0.90 for MRI-ellipsoid, 0.73 for SPV-ellipsoid, 0.72 for MRI-bullet, 0.71 for TRUS, 0.70 for SPW, 0.66 for SPV-bullet, 0.38 for MRI-A3D, and 0.33 for DRE. Conclusions: With MRI-R3D measurement as the reference, the most reliable methods for PV estimation were MRI-S3D and MRI-ellipsoid formula. Automated segmentations must be individually assessed for accuracy, as they are not always truly representative of the prostate anatomy. Manual segmentation of the prostate does not require expert training.
引用
收藏
页码:1582 / 1587
页数:6
相关论文
共 26 条
[1]   Active Surveillance for Low-Risk Prostate Cancer Worldwide: The PRIAS Study [J].
Bul, Meelan ;
Zhu, Xiaoye ;
Valdagni, Riccardo ;
Pickles, Tom ;
Kakehi, Yoshiyuki ;
Rannikko, Antti ;
Bjartell, Anders ;
van der Schoot, Deric K. ;
Cornel, Erik B. ;
Conti, Giario N. ;
Boeve, Egbert R. ;
Staerman, Frederic ;
Vis-Maters, Jenneke J. ;
Vergunst, Henk ;
Jaspars, Joris J. ;
Stroelin, Petra ;
van Muilekom, Erik ;
Schroder, Fritz H. ;
Bangma, Chris H. ;
Roobol, Monique J. .
EUROPEAN UROLOGY, 2013, 63 (04) :597-603
[2]   Appropriateness Criteria for Active Surveillance of Prostate Cancer [J].
Cher, Michael L. ;
Dhir, Apoorv ;
Auffenberg, Gregory B. ;
Linsell, Susan ;
Gao, Yuqing ;
Rosenberg, Bradley ;
Jafri, S. Mohammad ;
Klotz, Laurence ;
Miller, David C. ;
Ghani, Khurshid R. ;
Bernstein, Steven J. ;
Montie, James E. ;
Lane, Brian R. .
JOURNAL OF UROLOGY, 2017, 197 (01) :67-74
[3]   Accuracy and repeatability of prostate volume measurements by transrectal ultrasound [J].
Eri, LM ;
Thomassen, H ;
Brennhovd, B ;
Håheim, LL .
PROSTATE CANCER AND PROSTATIC DISEASES, 2002, 5 (04) :273-278
[4]   Individualization of the biopsy protocol according to the prostate gland volume for prostate cancer detection [J].
Eskicorapci, SY ;
Guliyev, F ;
Akdogan, B ;
Dogan, HS ;
Ergen, A ;
Ozen, H .
JOURNAL OF UROLOGY, 2005, 173 (05) :1536-1540
[5]   Clinical value of prostate segmentation and volume determination on MRI in benign prostatic hyperplasia [J].
Garvey, Brian ;
Tuerkbey, Baris ;
Truong, Hong ;
Bernardo, Marcelino ;
Periaswamy, Senthil ;
Choyke, Peter L. .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2014, 20 (03) :229-233
[6]   A survey of prostate segmentation methodologies in ultrasound, magnetic resonance and computed tomography images [J].
Ghose, Soumya ;
Oliver, Arnau ;
Marti, Robert ;
Llado, Xavier ;
Vilanova, Joan C. ;
Freixenet, Jordi ;
Mitra, Jhimli ;
Sidibe, Desire ;
Meriaudeau, Fabrice .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2012, 108 (01) :262-287
[7]   Statistical shape and texture model of quadrature phase information for prostate segmentation [J].
Ghose, Soumya ;
Oliver, Arnau ;
Marti, Robert ;
Llado, Xavier ;
Freixenet, Jordi ;
Mitra, Jhimli ;
Vilanova, Joan C. ;
Comet-Batlle, Josep ;
Meriaudeau, Fabrice .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (01) :43-55
[8]  
Hsieh Teng-Fu, 2005, J Chin Med Assoc, V68, P167
[9]   Prostate volume reduction with androgen deprivation therapy before interstitial brachytherapy [J].
Kucway, R ;
Vicini, F ;
Huang, RW ;
Stromberg, J ;
Gonzalez, J ;
Martinez, A .
JOURNAL OF UROLOGY, 2002, 167 (06) :2443-2447
[10]   Transrectal ultrasound versus magnetic resonance imaging in the estimation of prostate volume as compared with radical prostatectomy specimens [J].
Lee, Jae Seok ;
Chung, Byung Ha .
UROLOGIA INTERNATIONALIS, 2007, 78 (04) :323-327