Single lateral locked screw plating of bicondylar tibial plateau fractures

被引:136
作者
Gosling, T
Schandelmaier, P
Muller, M
Hankemeier, S
Wagner, M
Krettek, C
机构
[1] Hannover Med Sch, D-3000 Hannover, Germany
[2] Klinikum Deggendorf, Deggendorf, Germany
[3] AO Clin Invest & Documentat Inst, Davos, Switzerland
[4] Wilhelminen Spital, Trauma Dept, Vienna, Austria
关键词
D O I
10.1097/01.blo.0000176147.31756.4c
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We prospectively followed a case series of 68 patients with 69 AO/ASIF 41-C-type fractures treated with the Less Invasive Stabilization System for the proximal lateral tibia. We assessed malreduction, secondary loss of reduction, and infection rates in patients with a locked screw plate for unilateral fixation of bicondylar fractures. Sixty-two (91%) patients returned for final followup (range, 11-13 months). Malreduction and malalignment were defined as an intraarticular step-off of 2 mm or greater, or as a malalignment in the frontal or sagittal plane greater than 5 degrees. Fourteen fractures were open. Primary bone grafting was done in 13 patients. Significant malreduction was seen in 16 patients. There were four superficial infections and one deep infection. One fracture did, note heal, and. nine patients had substantial loss of reduction. Unilateral locked screw plating is a good alternative for treatment of problematic fractures of the tibial plateau that are associated with soft tissue damage and metaphyseal comminution. The reduction technique for exact alignment is demanding.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 44 条
[1]   Outcome of complex fractures of the tibial plateau treated with a beam-loading ring fixation system [J].
Ali, AM ;
Burton, M ;
Hashmi, M ;
Saleh, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (05) :691-699
[2]   LISS-Tractor. Combination of the less invasive stabilization system (LISS) with the AO distractor for fractures of the distal femur and proximal tibia [J].
Babst, R ;
Hehli, M ;
Regazzoni, P .
UNFALLCHIRURG, 2001, 104 (06) :530-535
[3]   Effect of articular step-off and meniscectomy on joint alignment and contact pressures for fractures of the lateral tibial plateau [J].
Bai, B ;
Kummer, FJ ;
Sala, DA ;
Koval, KJ ;
Wolinsky, PR .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (02) :101-106
[4]   Treatment of tibial plateau fractures with small fragment internal fixation:: A preliminary report [J].
Ballmer, FT ;
Hertel, R ;
Nötzli, HP .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (07) :467-474
[5]   Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique [J].
Barei, DP ;
Nork, SE ;
Mills, WJ ;
Henley, MB ;
Benirschke, SK .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (10) :649-657
[6]  
Benirschke S K, 1992, J Orthop Trauma, V6, P78
[7]   THE RESULTS OF SURGICAL-MANAGEMENT OF DISPLACED TIBIAL PLATEAU FRACTURES IN THE ELDERLY [J].
BIYANI, A ;
REDDY, NS ;
CHAUDHURY, J ;
SIMISON, AJM ;
KLENERMAN, L .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1995, 26 (05) :291-297
[8]  
Cole P A, 2003, Injury, V34 Suppl 1, pA16
[9]   Treatment of high-energy tibial plateau fractures by the Ilizarov circular fixator [J].
Dendrinos, GK ;
Kontos, S ;
Katsenis, D ;
Dalas, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (05) :710-717
[10]   The development of the distal femur Less Invasive Stabilization System (LISS) [J].
Frigg, R ;
Appenzeller, A ;
Christensen, R ;
Frenk, A ;
Gilbert, S ;
Schavan, R .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 :24-31