JT-60U plasma current measurement by an optical current transformer

被引:2
作者
Arai, T [1 ]
Nishiyama, T
Yagyu, J
Kasai, S
Sone, I
Abe, M
Miya, N
机构
[1] Japan Atom Energy Res Inst, Naka Fus Res Estab, Naka, Ibaraki 3110193, Japan
[2] Hitachi Ltd, Power & Ind Syst R&D Lab 1, Hitachi, Ibaraki 3191221, Japan
关键词
D O I
10.13182/FST04-A428
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In a nuclear fusion experiment device, a plasma discharge is to be sustained for a long time in steady state operation. In such a device an electromagnetic sensor that has a signal integrator to measure direct currents will cause a technical problem of zero point drift on signals. Therefore, the detection device using new technology for direct current measurement, optical current transformer (optical CT), was developed The device has an optical fiber specified for850 and 1550nm (wavelength) were manufactured, and was applied to current measurement in JT-60U experiments. A gamma ray irradiation examination was also done to the optical CT.
引用
收藏
页码:65 / 68
页数:4
相关论文
共 4 条
[1]  
ABE M, 2001, MEASUREMENT PLASMA C
[2]  
BLAKE J, 1996, IEEE T POWER DELIVER, V11, pP116
[3]   DESIGN AND DEVELOPMENT OF JT-60 UPGRADE - VACUUM VESSEL AND 1ST WALL [J].
HORIIKE, H ;
ANDO, T ;
KUSHIMA, T ;
MATSUKAWA, M ;
NEYATANI, Y ;
NINOMIYA, H ;
YAMAMOTO, M .
FUSION ENGINEERING AND DESIGN, 1991, 16 :285-292
[4]  
ICHINOSE Y, 1999, 46 JSAP SPRING M NOD