Use of Verisyse/Artisan phakic intraocular lens for the reduction of myopia in a patient with pellucid marginal degeneration

被引:9
|
作者
de Vries, Niels E. [1 ]
Tahzib, Nayyirih G. [1 ]
Webers, Carroll A. B. [1 ]
Hendrikse, Fred [1 ]
Nuijts, Rudy M. M. A. [1 ]
机构
[1] Acad Hosp Maastricht, Dept Ophthalmol, NL-6202 AZ Maastricht, Netherlands
关键词
pellucid marginal degeneration; Verisyse/Artisan phakic; intraocular lens; progression; myopia;
D O I
10.1097/ICO.0b013e31815b82b6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe a patient who underwent implantation of a Verisyse/Artisan iris-fixated phakic intraocular lens (IOL) for correction of high myopia in pellucid marginal degeneration (PMD). Methods: A patient with PMD was observed during a period of 7 years after the implantation of a Verisyse/Artisan phakic IOL. At each visit, slit-lamp evaluation was performed, and corneal topography, endothelial cell count, manifest refraction, and uncorrected and best-corrected visual acuity were determined. Results: Verisyse/Artisan phakic IOL implantation was performed for the correction of the patient's high myopia in the presence of early-stage PMD. The preoperative refraction of the right eye was -13.0-3.0 X 90 degrees. The postoperative spherical equivalent (SE) was +0.50 D after I year and +0.50 D after 7 years. The preoperative refraction of the left eye was -13.0 -1.25 X 55 degrees. The postoperative SE was -0.38 D after I year and -0.13 D after 7 years. Preoperative topographic astigmatism for the right and left eye was 2.94 and 0.81 D, respectively. Seven years later, topographic astigmatism for the right and left eye had changed to 4.45 and 0.71 D, respectively. Conclusions: This case shows that the implantation of a Verisyse/Artisan phakic IOL may be effective in the treatment of refractive error in PMD. This case discusses the value of a removable (as opposed to a permanent) solution, such as the Verisyse/Artisan phakic IOL device, in the treatment of refractive error in PMD.
引用
收藏
页码:241 / 245
页数:5
相关论文
共 40 条
  • [21] 5-Year Prospective Follow-Up of Artisan Phakic Intraocular Lenses for the Correction of Myopia, Hyperopia and Astigmatism
    Qasem, Qasim
    Kirwan, Caitriona
    O'Keefe, Michael
    OPHTHALMOLOGICA, 2010, 224 (05) : 283 - 290
  • [22] FLUOROPHOTOMETRY IN PHAKIC EYES WITH ANTERIOR-CHAMBER INTRAOCULAR-LENS IMPLANTATION TO CORRECT MYOPIA
    DELCASTILLO, JMB
    HERNANDEZ, JL
    IRADIER, MT
    DELRIO, MT
    SANCHEZ, JG
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (05) : 607 - 609
  • [23] Long-term clinical results of posterior chamber phakic intraocular lens implantation to correct myopia
    Lee, Jongsoo
    Kim, Younghee
    Park, Saekwang
    Bae, Jungae
    Lee, Seunguk
    Park, Youngmin
    Lee, Jonghun
    Lee, Ji-Eun
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 44 (06) : 481 - 487
  • [24] Safety and Efficacy of a New Posterior Chamber Phakic Intraocular Lens in Cases of High Myopia: Early Results
    Subudhi, Praveen
    Patro, Sweta
    Agarwal, Prateek
    Khan, Zahiruddin
    Subudhi, B. Nageswar Rao
    Mekap, Chandan
    Padhi, Asutosh
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 3681 - 3689
  • [25] Visual Outcomes and Complications in a Comparative Study of Visian Implantable Contact Lens and Artisan Iris-fixated Phakic Intraocular Lens in a Myopic Cohort
    Al-Abdullah, Abdulelah
    Alfalah, Mohammed
    Khandekar, Rajiv
    Alreshaid, Saba Abdulmohsen
    Arevalo, J. Fernando
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [26] Long-term safety and efficacy of a foldable iris-fixated phakic intraocular lens for the correction of myopia
    Mariano Royo
    Ángel Jiménez
    David P. Piñero
    International Ophthalmology, 2023, 43 : 4491 - 4502
  • [27] Long-term safety and efficacy of a foldable iris-fixated phakic intraocular lens for the correction of myopia
    Royo, Mariano
    Jimenez, Angel
    Pinero, David P.
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (12) : 4491 - 4502
  • [28] Foldable iris-fixated phakic intraocular lens implantation for the correction of myopia: Two years of follow-up
    Ozerturk, Yusuf
    Kubaloglu, Anil
    Sari, Esin Sogutlu
    Koytak, Arif
    Capkin, Musa
    Akcay, Levent
    Evcili, Pinar Sorgun
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2012, 60 (01) : 23 - 28
  • [29] Five-year follow-up of a posterior chamber phakic intraocular lens with a central hole for correction of myopia
    Lwowski, Christoph
    Van Keer, Karel
    Ruscher, Tim
    Van Keer, Luisa
    Shajari, Mehdi
    Kohnen, Thomas
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (12) : 4933 - 4943
  • [30] Five-year follow-up of a posterior chamber phakic intraocular lens with a central hole for correction of myopia
    Christoph Lwowski
    Karel Van Keer
    Tim Ruscher
    Luisa Van Keer
    Mehdi Shajari
    Thomas Kohnen
    International Ophthalmology, 2023, 43 : 4933 - 4943