Intensifying the Cleaning of Emulsion- and Oil-Bearing Waste Water from Rolled-Product Manufacturing by Electroflotation

被引:1
|
作者
Maksimov, E. A. [1 ]
Ostsemin, A. A. [2 ]
机构
[1] Intrai Co, Chelyabinsk, Russia
[2] Russian Presidential Acad, Natl Econ & Publ Serv, Moscow, Russia
关键词
intensification of primary and secondary cleaning; emulsion- and oil-bearing waste water from rolling-mill operation; electroflotation;
D O I
10.1007/s11015-015-0022-8
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
It is shown that it is possible to intensify the cleaning of emulsion- and oil-bearing waste water from rolling-mill operation. The water is given a secondary treatment in an electrical flotation unit that automatically controls current density and electrode spacing. Operating regimes for the unit are developed for the secondary cleaning of emulsion-bearing waste water from cold-rolling mills after primary cleaning in horizontal settling tanks with reagent FeCl2, a small amount of H2SO4, and spent pickling solution. The optimum regime for use of the flotation unit for the secondary cleaning of oil-bearing waste water from hot-rolling mills is determined. A cleaning level of 94-95% is achieved for waste water in which the initial content of petroleum products is 100 mg/liter.