Measurement of occupants' stress based on electroencephalograms (EEG) in twelve combined environments

被引:121
作者
Choi, Yoorim [1 ]
Kim, Minjung [1 ]
Chun, Chungyoon [1 ]
机构
[1] Yonsei Univ, Dept Interior Architecture & Built Environm, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
Stress; EEG; Combined environment; Comfort; THERMAL COMFORT; PERFORMANCE; SCALE;
D O I
10.1016/j.buildenv.2014.10.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study examines the effects of indoor environment on stress levels. Temperature, oder irritants, and sound were selected as environmental elements to be studied within the combined environment, and these were individually controlled in a total of 12 combined environments with established climate chambers. The occupants' stress was measured using paper-based tests, and the two combined environments that showed the most different stress aspects were determined based on their results. A second test was then performed using an electroencephalogram (EEG), and in this test, occupants' stress in the two combined environments were compared using an EEG analysis to generate a brain map showing occupants' stress states from a physiological perspective. Experimental results indicate that occupants stress was maximized when they were exposed to a temperature of 30 degrees C, odor irritants (VOCs) and to road traffic noises. In this stressful environment, it is presumed that the differences in brain mapping of the relative high-beta wave in the temporal lobe can be useful when assessing participants' stress. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 26 条
  • [1] [Anonymous], 2008, EEG signal processing
  • [2] Thermal adaptation in the built environment: a literature review
    Brager, GS
    de Dear, RJ
    [J]. ENERGY AND BUILDINGS, 1998, 27 (01) : 83 - 96
  • [3] Clausen G., 1993, indoor Air, V3, P255, DOI DOI 10.1111/J.1600-0668.1993.00006.X
  • [4] Fanger P.O., 1970, Thermal comfort, V1st
  • [5] CAN COLOR AND NOISE INFLUENCE MANS THERMAL COMFORT
    FANGER, PO
    BREUM, NO
    JERKING, E
    [J]. ERGONOMICS, 1977, 20 (01) : 11 - 18
  • [6] Benefits and costs of improved IEQ in US offices
    Fisk, W. J.
    Black, D.
    Brunner, G.
    [J]. INDOOR AIR, 2011, 21 (05) : 357 - 367
  • [7] APPRAISAL, COPING, HEALTH-STATUS, AND PSYCHOLOGICAL SYMPTOMS
    FOLKMAN, S
    LAZARUS, RS
    GRUEN, RJ
    DELONGIS, A
    [J]. JOURNAL OF PERSONALITY AND SOCIAL PSYCHOLOGY, 1986, 50 (03) : 571 - 579
  • [8] Standard operative temperature, a generalized temperature scale, applicable to direct and partitional calorimetry
    Gagge, AP
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1940, 131 (01): : 0093 - 0103
  • [9] Girdano DA, 1986, OCCUPATIONAL HLTH PR
  • [10] Hinkle L E Jr, 1973, Sci Med Man, V1, P31