Maximum likelihood activity and attenuation estimation using both emission and transmission data with application to utilization of Lu-176 background radiation in TOF PET

被引:6
作者
Cheng, Li [1 ,2 ]
Ma, Tianyu [2 ]
Zhang, Xuezhu [1 ]
Peng, Qiyu [3 ]
Liu, Yaqiang [2 ]
Qi, Jinyi [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[3] Lawrence Berkeley Natl Lab, Struct Biol & Imaging Dept, Berkeley, CA 94720 USA
基金
中国国家自然科学基金;
关键词
attenuation correction; joint activity and attenuation estimation; Lu-176 background radiation; time-of-flight (TOF) positron emission tomography (PET); TIME-OF-FLIGHT; SIMULTANEOUS RECONSTRUCTION; IMAGE-RECONSTRUCTION; CT; PERFORMANCE; RESOLUTION; ALGORITHMS; SIMULATION; VARIANCE;
D O I
10.1002/mp.13989
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose We present a new method for joint reconstruction of activity and attenuation images using both emission and transmission data and demonstrate its advantage over the standard maximum likelihood activity and attenuation (MLAA) reconstruction using emission data alone. Methods We define a joint likelihood function including both time-of-flight (TOF) emission data and transmission data. The latter can be obtained from an external source or from Lu-176 background radiation. Activity and attenuation images are estimated jointly by maximizing the likelihood function. The proposed method solves the undetermined scale problem in the conventional MLAA. A monotonically convergent algorithm was derived to optimize the objective function. Furthermore, we present a theoretical analysis of the noise propagation in the joint reconstruction. Simulations and phantom experiments were conducted to validate the feasibility of the proposed method. Results Quantitatively correct and less noisy images were reconstructed with the proposed method. Artifacts in the attenuation map reconstructed from the standard MLAA were removed by incorporating transmission data. Noise analysis was validated with different transmission sources and transmission count levels. The theoretical prediction indicated that noise of activity map would not change in a large range of transmission count level and a very low transmission count level could result in good estimation. Conclusions The results demonstrate the feasibility of obtaining quantitatively correct images in TOF PET by using both emission and (weak) transmission data. The noise analysis also provides guidance for choosing a proper transmission source configuration to reduce noise propagation.
引用
收藏
页码:1067 / 1082
页数:16
相关论文
共 33 条
[1]   A generalized model for the conversion from CT numbers to linear attenuation coefficients [J].
Bai, CY ;
Shao, L ;
Da Silva, AJ ;
Zhao, Z .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1510-1515
[2]   Nuclear data sheets for A=176 [J].
Basunia, MS .
NUCLEAR DATA SHEETS, 2006, 107 (04) :791-+
[3]  
Berger MJ, 2005, XCOM PHOTONCROSS SEC
[4]   PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients [J].
Burger, C ;
Goerres, G ;
Schoenes, S ;
Buck, A ;
Lonn, AHR ;
von Schulthess, GK .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (07) :922-927
[5]   Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care [J].
Cherry, Simon R. ;
Jones, Terry ;
Karp, Joel S. ;
Qi, Jinyi ;
Moses, William W. ;
Badawi, Ramsey D. .
JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (01) :3-12
[6]   Why is TOF PET reconstruction a more robust method in the presence of inconsistent data? [J].
Conti, Maurizio .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (01) :155-168
[7]   Time-of-flight PET data determine the attenuation sinogram up to a constant [J].
Defrise, Michel ;
Rezaei, Ahmadreza ;
Nuyts, Johan .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (04) :885-899
[8]   Ordered subsets algorithms for transmission tomography [J].
Erdogan, H ;
Fessler, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :2835-2851
[9]  
Erdogan H, BIOM IM 2002 5 IEEE
[10]   Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): Applications to tomography [J].
Fessler, JA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (03) :493-506