Technology Insight: magnetic resonance angiography for the evaluation of patients with peripheral artery disease

被引:12
作者
Dellegrottaglie, Santo
Sanz, Javier
Macaluso, Frank
Einstein, Andrew J.
Raman, Subha
Simonetti, Orlando P.
Rajagopalan, Sanjay
机构
[1] Ohio State Univ, Div Cardiovasc Med, Columbus, OH 43210 USA
[2] Columbia Univ Coll Phys & Surg, Cardiovasc Inst, New York, NY USA
[3] Columbia Univ Coll Phys & Surg, Mt Sinai Med Ctr, Ctr Cardiovasc Hlth, New York, NY USA
[4] Columbia Univ Coll Phys & Surg, Dept Med, Dept Radiol, Div Cardiol & Surg, New York, NY USA
[5] Ohio State Univ, Div Cardiovasc Med, Cardiovasc MRI & CT Res, Columbus, OH USA
来源
NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE | 2007年 / 4卷 / 12期
关键词
atherosclerosis; imaging; MRI; peripheral vascular disease;
D O I
10.1038/ncpcardio1035
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Peripheral arterial disease (PAD) is a common manifestation of systemic atherosclerosis. Although clinical history in conjunction with ankle-brachial index and evaluation of segmental pressures/waveforms is sufficient to diagnose PAD in a large percentage of patients, imaging is required for disease localization and treatment planning. Contrast-enhanced magnetic resonance angiography (CE-MRA) is a noninvasive, three-dimensional technique that has emerged as a front-line imaging approach for comprehensive evaluation of PAD. Technical advances such as parallel imaging and moving-table, time-resolved angiography and extended field-of-view approaches have greatly improved the accuracy of CE-MRA. In the clinical setting, CE-MRA can be extremely helpful in the initial diagnosis as well as subsequent management of patients with PAD. Continued hardware and software improvements will enable further refinements in imaging protocol for peripheral MRA, consolidating its clinical role for the evaluation of patients with PAD.
引用
收藏
页码:677 / 687
页数:11
相关论文
共 69 条
  • [11] Whole-body MR angiography using a novel 32-receiving-channel MR system with surface coil technology: First clinical experience
    Fenchel, M
    Requardt, M
    Tomaschko, K
    Kramer, U
    Stauder, NI
    Naegele, T
    Schlemmer, HP
    Claussen, CD
    Miller, S
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (05) : 596 - 603
  • [12] Lower extremity arterial evaluation: Are segmental arterial blood pressures worthwhile?
    Gale, SS
    Scissons, RP
    Salles-Cunha, SX
    Dosick, SM
    Whalen, RC
    Pigott, JP
    Beebe, HG
    [J]. JOURNAL OF VASCULAR SURGERY, 1998, 27 (05) : 831 - 839
  • [13] Gadolinium-enhanced magnetic resonance angiography, colour duplex and digital subtraction angiography of the lower limb arteries from the aorta to the tibio-peroneal trunk in patients with intermittent claudication
    Gjonnæss, E
    Morken, B
    Sandbæk, G
    Stranden, E
    Slagsvold, CE
    Jorgensen, JJ
    Nylænde, M
    Abdelnoor, M
    Dullerud, R
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2006, 31 (01) : 53 - 58
  • [14] MR angiography of aortoiliac occlusive disease: A phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325
    Goyen, M
    Edelman, M
    Perreault, P
    O'Riordan, E
    Bertoni, H
    Taylor, J
    Siragusa, D
    Sharafuddin, M
    Mohler, ER
    Breger, R
    Yucel, EK
    Shamsi, K
    Weisskoff, RM
    [J]. RADIOLOGY, 2005, 236 (03) : 825 - 833
  • [15] Gadopentetate dimeglumine-enhanced three-dimensional MR-angiography: Dosing, safety, and efficacy
    Goyen, M
    Debatin, JF
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (03) : 261 - 273
  • [16] Detection of atherosclerosis:: Systemic imaging for systemic disease with whole-body three-dimensional MR angiography -: Initial experience
    Goyen, M
    Herborn, CU
    Kröger, K
    Lauenstein, TC
    Debatin, JF
    Ruehm, SG
    [J]. RADIOLOGY, 2003, 227 (01) : 277 - 282
  • [17] Optimization of contrast dosage for gadobenate dimeglumine-enhanced high-resolution whole-body 3D magnetic resonance angiography
    Goyen, M
    Herborn, CU
    Lauenstein, TC
    Barkhausen, J
    Veit, P
    Bosk, S
    Debatin, JF
    Ruehm, SG
    [J]. INVESTIGATIVE RADIOLOGY, 2002, 37 (05) : 263 - 268
  • [18] Whole-body three-dimensional MR angiography with a rolling table platform:: Initial clinical experience
    Goyen, M
    Quick, HH
    Debatin, JF
    Ladd, ME
    Barkhausen, J
    Herborn, CU
    Bosk, S
    Kuehl, H
    Schlepütz, M
    Ruehm, SG
    [J]. RADIOLOGY, 2002, 224 (01) : 270 - 277
  • [19] Whole-body magnetic resonance angiography of patients using a standard clinical scanner
    Hansen, T
    Wikström, J
    Eriksson, MO
    Lundberg, A
    Johansson, L
    Ljungman, C
    Hoogeven, R
    Ahlström, H
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (01) : 147 - 153
  • [20] Gadobutrol-enhanced moving-table magnetic resonance angiography in patients with peripheral vascular disease:: a prospective, multi-centre blinded comparison with digital subtraction angiography
    Hentsch, A
    Aschauer, MA
    Balzer, JO
    Brossmann, J
    Busch, HP
    Davis, K
    Douek, P
    Ebner, F
    van Engelshoven, JMA
    Gregor, M
    Kersting, C
    Knüsel, PR
    Leen, E
    Leiner, T
    Loewe, C
    McPherson, S
    Reimer, P
    Schäfer, FKW
    Taupitz, M
    Thurnher, SA
    Tombach, B
    Wegener, R
    Weishaupt, D
    Meaney, JFM
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (09) : 2103 - 2114