Technology Insight: magnetic resonance angiography for the evaluation of patients with peripheral artery disease

被引:12
作者
Dellegrottaglie, Santo
Sanz, Javier
Macaluso, Frank
Einstein, Andrew J.
Raman, Subha
Simonetti, Orlando P.
Rajagopalan, Sanjay
机构
[1] Ohio State Univ, Div Cardiovasc Med, Columbus, OH 43210 USA
[2] Columbia Univ Coll Phys & Surg, Cardiovasc Inst, New York, NY USA
[3] Columbia Univ Coll Phys & Surg, Mt Sinai Med Ctr, Ctr Cardiovasc Hlth, New York, NY USA
[4] Columbia Univ Coll Phys & Surg, Dept Med, Dept Radiol, Div Cardiol & Surg, New York, NY USA
[5] Ohio State Univ, Div Cardiovasc Med, Cardiovasc MRI & CT Res, Columbus, OH USA
来源
NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE | 2007年 / 4卷 / 12期
关键词
atherosclerosis; imaging; MRI; peripheral vascular disease;
D O I
10.1038/ncpcardio1035
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Peripheral arterial disease (PAD) is a common manifestation of systemic atherosclerosis. Although clinical history in conjunction with ankle-brachial index and evaluation of segmental pressures/waveforms is sufficient to diagnose PAD in a large percentage of patients, imaging is required for disease localization and treatment planning. Contrast-enhanced magnetic resonance angiography (CE-MRA) is a noninvasive, three-dimensional technique that has emerged as a front-line imaging approach for comprehensive evaluation of PAD. Technical advances such as parallel imaging and moving-table, time-resolved angiography and extended field-of-view approaches have greatly improved the accuracy of CE-MRA. In the clinical setting, CE-MRA can be extremely helpful in the initial diagnosis as well as subsequent management of patients with PAD. Continued hardware and software improvements will enable further refinements in imaging protocol for peripheral MRA, consolidating its clinical role for the evaluation of patients with PAD.
引用
收藏
页码:677 / 687
页数:11
相关论文
共 69 条
  • [1] Surveillance of peripheral arterial bypass grafts with three dimensional MR angiography: Comparison with digital subtraction angiography
    Bertschinger, K
    Cassina, PC
    Debatin, JF
    Ruehm, SG
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (01) : 215 - 220
  • [2] Contrast-enhanced bolus-chased whole-body MR angiography using a moving tabletop and quadrature body coil acquisition
    Brennan, DD
    Johnston, C
    O'Brien, J
    Taylor, DH
    Cronin, C
    Eustace, SJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (03) : 750 - 755
  • [3] High resolution magnetic resonance imaging of atherosclerosis and the response to balloon angioplasty
    Coulden, RA
    Moss, H
    Graves, MJ
    Lomas, DJ
    Appleton, DS
    Weissberg, PL
    [J]. HEART, 2000, 83 (02) : 188 - 191
  • [4] MORTALITY OVER A PERIOD OF 10 YEARS IN PATIENTS WITH PERIPHERAL ARTERIAL-DISEASE
    CRIQUI, MH
    LANGER, RD
    FRONEK, A
    FEIGELSON, HS
    KLAUBER, MR
    MCCANN, TJ
    BROWNER, D
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (06) : 381 - 386
  • [5] Magnetic resonance angiography unmasks reliable target vessels for pedal bypass grafting in patients with diabetes mellitus
    Dorweiler, B
    Neufang, A
    Kreitner, KF
    Schmiedt, W
    Oelert, H
    [J]. JOURNAL OF VASCULAR SURGERY, 2002, 35 (04) : 766 - 772
  • [6] Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels
    Du, J
    Carroll, TJ
    Wagner, HJ
    Vigen, K
    Fain, SB
    Block, WF
    Korosec, FR
    Grist, TM
    Mistretta, CA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) : 516 - 522
  • [7] Peripheral vascular surgery and magnetic resonance arteriography - a review
    Eiberg, JP
    Lundorf, E
    Thomsen, C
    Schroeder, TV
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2001, 22 (05) : 396 - 402
  • [8] In vivo magnetic resonance evaluation of atherosclerotic plaques in the human thoracic aorta - A comparison with transesophageal echocardiography
    Fayad, ZA
    Nahar, T
    Fallon, JT
    Goldman, M
    Aguinaldo, JG
    Badimon, JJ
    Shinnar, M
    Chesebro, JH
    Fuster, V
    [J]. CIRCULATION, 2000, 101 (21) : 2503 - 2509
  • [9] Fayad ZA, 2000, CIRCULATION, V102, P506
  • [10] Atherosclerotic disease:: Whole-body cardiovascular imaging with MR system with 32 receiver channels and total-body surface coil technology -: Initial clinical results
    Fenchel, M
    Scheule, AM
    Stauder, NI
    Kramer, U
    Tomaschko, K
    Nägele, T
    Bretschneider, C
    Schlemmer, HP
    Claussen, CD
    Miller, S
    [J]. RADIOLOGY, 2006, 238 (01) : 280 - 291