A Retrospective Study of Bone-Level Stability Around 335 Hybrid Implants Placed with an Immediate or Delayed Protocol

被引:0
作者
Wagenberg, Barry D. [1 ]
Froum, Stuart J. [2 ]
Forman, Jerome
Kim, Soo-Woo [3 ]
机构
[1] Newark Beth Israel Med Ctr, Dept Dent, Newark, NJ USA
[2] NYU, Coll Dent, Ashman Dept Periodontol & Implant Dent, New York, NY USA
[3] Harvard Sch Dent Med, Dept Oral Med Infect & Immun, Boston, MA USA
关键词
ACID-ETCHED SURFACE; TITANIUM IMPLANTS; MULTICENTER; ROUGHNESS; MAXILLA; 5-YEAR;
D O I
10.11607/prd.5666
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This retrospective study evaluated 335 hybrid implants placed in edentulous ridges; 167 were placed with an immediate implant protocol (IIP) and 168 were placed with a delayed implant protocol. Radiographic bone level changes were measured 1 to 23 years after loading. The average bone loss between implant placement and second-stage loading was 0.16 mm in the delayed group and 0.12 mm in the IIP group. Average bone loss from implant loading to the final radiograph was 0.26 mm in the IIP group and 0.13 mm in the delayed group. There was statistically significantly more bone loss in the IIP group, in patients taking amoxicillin (vs those taking azithromycin), in sites with splinted implants (vs nonsplinted implants), and in smokers (vs nonsmokers). However, even when statistically significant, bone loss would be considered clinically insignificant by most clinicians over the 1- to 23-year follow-up.
引用
收藏
页码:647 / +
页数:10
相关论文
共 17 条
  • [1] OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN
    ALBREKTSSON, T
    BRANEMARK, PI
    HANSSON, HA
    LINDSTROM, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02): : 155 - 170
  • [2] [Anonymous], 1991, J BIOMECHANICS
  • [3] Engineering biocompatible implant surfaces Part I: Materials and surfaces
    Bauer, Sebastian
    Schmuki, Patrik
    von der Mark, Klaus
    Park, Jung
    [J]. PROGRESS IN MATERIALS SCIENCE, 2013, 58 (03) : 261 - 326
  • [4] Branemark PI, 1985, OSSEOINTEGRATION CLI, V1st, P241
  • [5] Buser D, 1998, INT J ORAL MAX IMPL, V13, P611
  • [6] Buser D, 1999, J BIOMED MATER RES, V45, P75, DOI 10.1002/(SICI)1097-4636(199905)45:2<75::AID-JBM1>3.0.CO
  • [7] 2-P
  • [8] INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS
    BUSER, D
    SCHENK, RK
    STEINEMANN, S
    FIORELLINI, JP
    FOX, CH
    STICH, H
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07): : 889 - 902
  • [9] A Prospective Multicenter 5-Year Radiographic Evaluation of Crestal Bone Levels Over Time in 596 Dental Implants Placed in 192 Patients
    Cochran, David L.
    Nummikoski, Pirkka V.
    Schoolfield, John D.
    Jones, Archie A.
    Oates, Thomas W.
    [J]. JOURNAL OF PERIODONTOLOGY, 2009, 80 (05) : 725 - 733
  • [10] Cochran DL, 1998, J BIOMED MATER RES, V40, P1, DOI 10.1002/(SICI)1097-4636(199804)40:1<1::AID-JBM1>3.0.CO