This paper presents a case study of three-phase ferroresonance in a low-voltage power factor correction system and investigates the influence of harmonic distortion on the occurrence of ferroresonance. Ferroresonance is an extremely dangerous and rare phenomenon that causes overvoltages and overcurrents in the system and degrades the power quality. The study is carried out on real field measurements in an industrial plant where ferroresonance occurs in the power factor correction (PFC) system at the detuned reactor. The three-phase ferroresonance analysed in this paper is an extremely rare phenomenon that has never been reported in this type of configuration. The measurement results have shown that in this type of configuration the high harmonic distortion is a necessary condition for ferroresonance to occur. In such conditions, switching on the capacitor stage triggers the ferroresonance with quasi-periodic oscillations supported by the medium voltage grid. The main contribution is the analysis of the three-phase ferroresonance in the detuned PFC system and the influence of the harmonics on the occurrence of the ferroresonance in such a case. The possible solutions to this problem and recommendations to avoid this phenomenon are discussed.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] RELATIONSHIP BETWEEN VOLTAGE HARMONICS AND DISTORTION FACTOR IN ELECTRIC-POWER SYSTEMS
    MORI, H
    TSUZUKI, S
    SAKURAI, T
    KOJIMA, Y
    SATOH, N
    ELECTRIC POWER SYSTEMS RESEARCH, 1989, 17 (01) : 65 - 76
  • [42] Cost, reliability, and sensitivity of a stand-alone hybrid renewable energy system-A case study on a lecture building with low load factor
    Gangwar, S.
    Bhanja, D.
    Biswas, A.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2015, 7 (01)
  • [43] Reduced conduction loss zero voltage transition power factor correction converter with low cost
    Cho, JG
    Baek, JW
    Song, DI
    Sun, YS
    Woo, SH
    We, KJ
    INTELEC 97 - 19TH INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, PROCEEDINGS: POWER AND ENERGY SYSTEMS IN CONVERGING MARKETS, 1997, : 512 - 516
  • [44] Hybrid system of power factor correction
    Petrov, A. A.
    Shurov, N. I.
    INNOVATIONS AND PROSPECTS OF DEVELOPMENT OF MINING MACHINERY AND ELECTRICAL ENGINEERING, 2017, 87
  • [45] A study of power factor and harmonics in switched-mode power supplies
    Zhu, GY
    Wei, H
    Iannello, C
    Batarseh, I
    IEEE SOUTHEASTCON '99, PROCEEDINGS, 1999, : 278 - 283
  • [46] Parallel active harmonic filters: The electronic solution for harmonics and power factor correction
    Johnson, James R.
    IEEE Annual Textile, Fiber and Film Industry Technical Conference, 1999,
  • [47] Estimation and Analysis of Harmonics and Power Factor Correction in a Modern Steel Manufacturing Facility
    Khatua P.
    Murugesan S.
    Murali V.
    Journal of The Institution of Engineers (India): Series B, 2019, 100 (05) : 425 - 434
  • [48] Effect of power frequency excitation character on ferroresonance in neutral-grounded system
    惠萌
    刘崇新
    Chinese Physics B, 2010, 19 (12) : 113 - 118
  • [49] Effect of power frequency excitation character on ferroresonance in neutral-grounded system
    Hui Meng
    Liu Chong-Xin
    CHINESE PHYSICS B, 2010, 19 (12)
  • [50] Tariff rationalization for reactive power and harmonics regulation in low voltage distribution networks
    Jayaprakash Budhavarapu
    Mayurkumar Rajkumar Balwani
    Karthik Thirumala
    Vivek Mohan
    Siqi Bu
    Manoranjan Sahoo
    Electrical Engineering, 2022, 104 : 3807 - 3824