Evaluation of mammographic and clinical follow-up after 755 stereotactic vacuum-assisted breast biopsies

被引:21
作者
Rotter, K
Haentschel, G
Koethe, D
Goetz, L
Bornhofen-Pöschke, A
Lebrecht, A
Kölbl, H
Heywang-Koebrunner, S
机构
[1] Univ Halle Wittenberg, Dept Diagnost Radiol, D-06097 Halle An Der Saale, Germany
[2] Univ Halle Wittenberg, Dept Gynecol, D-06097 Halle An Der Saale, Germany
关键词
breast biopsy; vacuum assisted; follow-up; breast intervention;
D O I
10.1016/S0002-9610(03)00176-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Stereotactic vacuum-assisted breast biopsy is a new method that promises high accuracy and reliability. In order to avoid surgery in cases with benign histology the examination must be quality assured and the accuracy should be well established. We present follow-up data of 755 VBs with benign results. Methods: In all, 984 of 1268 consecutive VBs proved histopathologically benign (lobular carcinoma in situ and atypical ductal hyperplasia not included). Follow-up data are available for 755 of 984 (77%) lesions and constitute the basis of this evaluation. Follow-up mammograms were performed of 728 lesions at 6 to 67 months (mean 24, median 17.8) after VB. Results: Seven technically unsuccessful cases underwent immediate rebiopsy; 3 unsuccessful cases were diagnosed otherwise. No false negative occurred among the 752 followed-up, eventually successful VBs. On follow-up mammography 444 of 728 (61%) benign lesions proved radiologically completely removed, 284 (39%) partially. In 6 cases (0.8%) a surgical biopsy was performed again during the follow-up time confirming the benign result. No scar was seen in 96%, a slight scar in 3.8%, and a small stellate scar with possible diagnostic interference in 0.3%. Conclusions: A benign diagnosis of quality assured VB is very reliable and leads to no or minimal scarring (C) 2003 Excerpta Medica, Inc. All rights reserved.
引用
收藏
页码:134 / 142
页数:9
相关论文
共 35 条
[1]  
American College of Radiology, 1998, ILL BREAST IM REP DA
[2]  
ASPESTEGUIA L, 2002, EUR RADIOL, V12, P637
[3]   Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model [J].
Berg, WA ;
Krebs, TL ;
Campassi, C ;
Magder, LS ;
Sun, CCJ .
RADIOLOGY, 1997, 205 (01) :203-208
[4]  
Brem RF, 2001, AM SURGEON, V67, P388
[5]   Percutaneous core biopsy of the breast: Effect of operator experience and number of samples on diagnostic accuracy [J].
Brenner, RJ ;
Fajardo, L ;
Fisher, PR ;
Dershaw, DD ;
Evans, WP ;
Bassett, L ;
Feig, S ;
Mendelson, E ;
Jackson, V ;
Margolin, FR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (02) :341-346
[6]   Fine needle aspiration or core biopsy [J].
Britton, PD .
BREAST, 1999, 8 (01) :1-4
[7]   Vacuum-assisted stereotactic breast biopsy - Histologic underestimation of malignant lesions [J].
Burak, WE ;
Owens, KE ;
Tighe, MB ;
Kemp, L ;
Dinges, SA ;
Hitchcock, CL ;
Olsen, J .
ARCHIVES OF SURGERY, 2000, 135 (06) :700-703
[8]   Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsies [J].
Burbank, F .
RADIOLOGY, 1997, 204 (01) :153-156
[9]  
Cangiarella J, 2000, J SURG ONCOL, V74, P263, DOI 10.1002/1096-9098(200008)74:4<263::AID-JSO4>3.0.CO
[10]  
2-1