Preoperative intra aortic balloon pumps in patients undergoing coronary artery bypass grafting

被引:51
|
作者
Theologou, Thomas [2 ]
Bashir, Mohamad [3 ]
Rengarajan, Arvind [4 ]
Khan, Omar [2 ]
Spyt, Tom [5 ]
Richens, David [6 ]
Field, Mark [1 ]
机构
[1] Liverpool Heart & Chest Hosp, Dept Cardiothorac Surg, Liverpool L14 3PE, Merseyside, England
[2] City Hosp Nottingham, Dept Cardiothorac Surg, Nottingham, England
[3] Univ Hosp Birmingham, Queen Elizabeth Hosp, Birmingham, W Midlands, England
[4] Nothern Gen Hosp, Dept Cardiothorac Surg, Sheffield, S Yorkshire, England
[5] Glenfield Hosp, Dept Cardiac Surg, Leicester, Leics, England
[6] City Hosp Nottingham, Dept Cardiac Surg, Trent Cardiac Ctr, Nottingham, England
来源
COCHRANE DATABASE OF SYSTEMATIC REVIEWS | 2011年 / 01期
关键词
Coronary Artery Bypass [adverse effects; mortality; Intra-Aortic Balloon Pumping; Randomized Controlled Trials as Topic; Humans; HIGH-RISK PATIENTS; COUNTERPULSATION; SURGERY; SUPPORT; IMPROVES; THERAPY;
D O I
10.1002/14651858.CD004472.pub3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The intra aortic balloon pump (IABP) is a mechanical assist device which improves cardiac function. The device has a well-established place in algorithms for managing low cardiac output following cardiac surgery. There is increasing evidence that certain cardiac surgery patients benefit from a period of preoperative augmentation with the intra aortic balloon pump. Objectives To determine the effect of the preoperative intra aortic balloon pump on mortality and morbidity in a number of different patients groups undergoing coronary artery bypass grafting. Search strategy The Cochrane Central Register of Controlled Trials (CENTRAL) on The Cochrane Library (Issue 3, 2009), MEDLINE (2000 to August 2009), EMBASE (1998 to August 2009), BIOSIS previews (1969 to August 2009) and ISI Proceedings (1990 to August 2009) were searched. References and ongoing registers of studies were checked. No language restrictions were applied. Selection criteria Randomised controlled trials (RCTs) of any size or length were included. Data collection and analysis Papers were assessed for inclusion by two authors independently and differences were settled by consensus with a third author. Date are presented in the form of odds ratios (OR) and 95% confidence intervals (CI). Main results Six trials were included (five on-pump and one off-pump). This update adds the results of one further trial. Data from a total of 255 patients were included in the meta-analysis of mortality outcomes; all on-pump. Generally, the patients were considered as "high risk" and 132 were treated preoperatively with IABP and 123 served as controls. There were four hospital deaths in the intervention arm and 23 in the non-intervention arm (OR 0.18, 95% CI 0.08 to 0.41; P<0.0001). In a subgroup analysis, low cardiac index (<2.0 L/min/m(2)) was noted in 21 out of 105 patients in the treatment arm and 59 patients out of 88 in the non-treatment arm (OR 0.14, 95% CI: 0.08 to 0.25; P<0.00001). An off-pump versus on-pump analysis was not possible due to the limited number of off-pump studies. However a single well-conducted RCT suggested favourable effect of the preoperative IABP in off-pump patients. Authors' conclusions Evidence suggests that preoperative IABP may have a beneficial effect on mortality and morbidity in specific high risk patient groups undergoing coronary artery bypass grafting, however there are many problems with the quality, validity and generalisability of the trials. However, the available evidence is not robust enough to extend the use of IABP to truly elective, high risk patients. Defining more precisely which patient groups may benefit would be the challenge for the future.
引用
收藏
页数:32
相关论文
共 50 条
  • [1] Preoperative intra aortic balloon pumps in patients undergoing coronary artery bypass grafting
    Field, M. L.
    Rengarajan, A.
    Khan, O.
    Spyt, T.
    Richens, D.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2007, (01):
  • [2] Con: Prophylactic Preoperative Use of an Intra-aortic Balloon Pump Is Not Indicated in High-Risk Coronary Patients Undergoing Coronary Artery Bypass Grafting
    Barker, Andrew B.
    Townsley, Matthew M.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (02) : 534 - 535
  • [3] Pro: Prophylactic Preoperative Use of an Intra-aortic Balloon Pump Is Indicated in High-Risk Coronary Patients Undergoing Coronary Artery Bypass Grafting
    Zaky, Ahmed
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (02) : 532 - 533
  • [4] Early outcomes of Intra-Aortic Balloon Pump in Patients Undergoing Coronary Artery Bypass Grafting (CABG) Surgery
    Farogh, Ajwad
    Bashir, Gohar
    Gull, Saira
    Ahmad, Naseem
    Hassan, Asama
    Waqas, Hafiz M.
    Afshan, Shamila
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (09): : 2422 - 2424
  • [5] The use of prophylactic intra-aortic balloon pump in high-risk patients undergoing coronary artery bypass grafting
    Nakamura, Ken
    Hamasaki, Azumi
    Uchida, Tetsuro
    Kobayashi, Kimihiro
    Sho, Ri
    Kim, Cholsu
    Uchino, Hideaki
    Shimanuki, Takao
    Sadahiro, Mitsuaki
    PLOS ONE, 2019, 14 (10):
  • [6] Predictors of intra-aortic balloon pump insertion in different spectrum of patients undergoing elective coronary artery bypass grafting
    Sahu M.K.
    Das A.
    Hote M.P.
    Rajashekar P.
    Sreenivas V.
    Airan B.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2017, 33 (4) : 296 - 302
  • [7] PREOPERATIVE CORONARY-ARTERY BYPASS-GRAFTING IN PATIENTS UNDERGOING ABDOMINAL AORTIC RECONSTRUCTION
    TOAL, KW
    JACOCKS, MA
    ELKINS, RC
    AMERICAN JOURNAL OF SURGERY, 1984, 148 (06): : 825 - 829
  • [8] Aggressive preoperative use of intraaortic balloon pump in elderly patients undergoing coronary artery bypass grafting
    Gutfinger, DE
    Ott, RA
    Miller, M
    Selvan, A
    Codini, MA
    Alimadadian, H
    Tanner, TM
    ANNALS OF THORACIC SURGERY, 1999, 67 (03): : 610 - 613
  • [9] Intra-aortic balloon pump placement in coronary artery bypass grafting patients by day of admission
    Gabriel A. del Carmen
    Andrea Axtell
    David Chang
    Serguei Melnitchouk
    Thoralf M. Sundt
    Amy G. Fiedler
    Journal of Cardiothoracic Surgery, 15
  • [10] Intra-aortic balloon pump placement in coronary artery bypass grafting patients by day of admission
    del Carmen, Gabriel A.
    Axtell, Andrea
    Chang, David
    Melnitchouk, Serguei
    Sundt, Thoralf M., III
    Fiedler, Amy G.
    JOURNAL OF CARDIOTHORACIC SURGERY, 2020, 15 (01)