Image quality and attenuation values of multidetector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400

被引:24
|
作者
Kim, Eun Young [1 ,2 ,3 ]
Yeh, Dae Wook [1 ,2 ]
Choe, Yeon Hyeon [1 ,2 ]
Lee, Won Jae [1 ,2 ]
Lim, Hyo Keun [1 ,2 ]
机构
[1] Sungkyunkwan Univ, Dept Radiol, Sch Med, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Cardiovasc Imaging Ctr, Sch Med, Samsung Med Ctr, Seoul 135710, South Korea
[3] Gachon Univ Gil Hosp, Dept Radiol, Inchon, South Korea
关键词
Coronary arteries; CT angiography; contrast agent; COMPUTED-TOMOGRAPHY; ENHANCEMENT; PRINCIPLES; MEDIA;
D O I
10.3109/02841851.2010.509740
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Effects of high iodine-concentration contrast material on the image quality of coronary CT angiography (CCTA) have not been well evaluated. Purpose: To compare the image quality and attenuation values of CCTA between patients administered iopromide 370 and iomeprol 400 with the use of 64-slice multidetector CT. Material and Methods: Patients were prospectively enrolled and were randomized into two groups (group A, 151 patients received iopromide 370, iodine flux = 1.48 g I/s; group B, 146 patients received iomeprol 400, iodine flux = 1.60 g I/s). CT attenuation was measured in the coronary arteries and great arteries and measurements were standardized based on an iodine flux of 1.50 g I/s. The image quality of 15 coronary artery segments was graded by two radiologists in consensus with the use of a four-point scale (1 = excellent to 4 = poor enhancement). Non-parametric statistical approaches were used to compare the two groups. Results: The median attenuation values in the coronary arteries were 454 HU and 464 HU for iopromide 370 and iomeprol 400, respectively, and they did not differ (P = 0.26). When standardizing for an iodine flux, significantly higher attenuation values were found for iopromide 370 (median = 460 HU, range = 216-791 HU) compared with iomeprol 400 (median = 435 HU, range = 195-758 HU) (P = 0.006). The median image quality score of coronary arterial segments was 1 (range 1-2) for both groups (P - 0.84). Conclusion: The attenuation values in the coronary arteries after injection of the same amount of two high iodine-concentration contrast materials at the same flow rate with different iodine fluxes are similar with no difference in image quality. With standardization for an iodine flux, the attenuation is significantly higher when using iopromide 370.
引用
收藏
页码:982 / 989
页数:8
相关论文
共 12 条
  • [1] Image quality and attenuation values of multidetector CTcoronary angiography using high iodine-concentration contrast material: a comparison of the use of iopromide 300 and iopromide 370
    Farouk, Mohamed Moustafa
    Darwish, Amr
    Adel, Amr
    Hafez, Hanan
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0K) : K1 - K2
  • [2] CT angiography covering both cervical and cerebral arteries using high iodine concentration contrast material with dose reduction on a 16 multidetector-row system
    Fujikawa, Akira
    Tsuchiya, Kazuhiro
    Imai, Masamichi
    Nitatori, Toshiaki
    NEURORADIOLOGY, 2010, 52 (04) : 291 - 295
  • [3] Comparison of coronary computed tomography angiography image quality with high- and low-concentration contrast agents (CONCENTRATE): study protocol for a randomized controlled trial
    Im, Dong Jin
    Kim, Yun-Hyeon
    Choo, Ki Seok
    Kang, Joon-Won
    Jung, Jung Im
    Won, Yoodong
    Kim, Hyo Rim
    Chung, Myung Hee
    Han, Kyunghwa
    Choi, Byoung Wook
    TRIALS, 2016, 17
  • [4] Comparison of Coronary Computed Tomography Angiography Image Quality With High-concentration and Low-concentration Contrast Agents The Randomized CONCENTRATE Trial
    Im, Dong Jin
    Kim, Yun-Hyeon
    Choo, Ki Seok
    Kang, Joon-Won
    Jung, Jung Im
    Won, Yoodong
    Kim, Hyo Rim
    Chung, Myung Hee
    Han, Kyunghwa
    Choi, Byoung Wook
    JOURNAL OF THORACIC IMAGING, 2023, 38 (02) : 120 - 127
  • [5] Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake
    Pan, Yue-ying
    Zhou, Shu-chang
    Wang, Yu-jin
    Li, Qian
    Zhu, Ting-ting
    Liu, Chun-xia
    Guan, Han-xiong
    CURRENT MEDICAL SCIENCE, 2020, 40 (01) : 178 - 183
  • [6] Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy
    Kim, Rihyeon
    Park, Eun-Ah
    Lee, Whal
    Chung, Jin Wook
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 3802 - 3810
  • [7] Comparison of contrast enhancement, image quality and tolerability in Coronary CT angiography using 4 contrast agents: A prospective randomized trial
    Honoris, Lily
    Zhong, Yan
    Chu, Edwin
    Rosenthal, David
    Li, Dong
    Lam, Franklin
    Budoff, Matthew J.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 186 : 126 - 128
  • [8] Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake
    Yue-ying Pan
    Shu-chang Zhou
    Yu-jin Wang
    Qian Li
    Ting-ting Zhu
    Chun-xia Liu
    Han-xiong Guan
    Current Medical Science, 2020, 40 : 178 - 183
  • [9] Multicenter Comparison of High Concentration Contrast Agent Iomeprol-400 With Iso-osmolar Iodixanol-320 Contrast Enhancement and Heart Rate Variation in Coronary Dual-Source Computed Tomographic Angiography
    Becker, Cristoph R.
    Vanzulli, Angelo
    Fink, Christian
    de Faveri, Daniele
    Fedeli, Stefano
    Dore, Roberto
    Biondetti, Pietro
    Kuettner, Alex
    Krix, Martin
    Ascenti, Giorgio
    INVESTIGATIVE RADIOLOGY, 2011, 46 (07) : 457 - 464
  • [10] Comparison of coronary computed tomography angiography image quality with high- and low-concentration contrast agents (CONCENTRATE): study protocol for a randomized controlled trial
    Dong Jin Im
    Yun-Hyeon Kim
    Ki Seok Choo
    Joon-Won Kang
    Jung Im Jung
    Yoodong Won
    Hyo Rim Kim
    Myung Hee Chung
    Kyunghwa Han
    Byoung Wook Choi