Sequential and simultaneous determination of four elements in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry

被引:27
作者
Boschetti, W. [1 ]
Orlando, M. [1 ]
Dullius, M. [2 ]
Dessuy, M. B. [1 ,3 ]
Vale, M. G. R. [1 ,3 ]
Welz, B. [3 ,4 ]
de Andrade, J. B. [3 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[2] Vinicola Geisse, Linha Jansen S-N, BR-95700000 Pinto Bandeira, RS, Brazil
[3] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq INCT Energia & Ambiente, Salvador, BA, Brazil
[4] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
AGRICULTURAL SOILS; TRACE-ELEMENTS; HEAVY-METALS; ACID DIGESTION; SOLID SAMPLES; AQUA REGIA; CADMIUM; CR; FE; TOXICITY;
D O I
10.1039/c6ja00031b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method has been developed for the sequential and simultaneous determination of Cd, Cr, Fe and Al (via the AlH molecule) in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry and direct solid sample analysis. First, Cd (228.802 nm) was determined using 800 degrees C and 1700 degrees C as the pyrolysis and atomization temperatures, respectively. Subsequently, after changing the wavelength, Cr (425.433 nm), Fe (425.076 nm) and Al (425.315 nm) were determined simultaneously from the same sample aliquot using 2600 degrees C as the atomization (Cr and Fe) or vaporization (AlH) temperature. Al determination was carried out using the diatomic molecule AlH without adding a molecule-forming reagent. The interference caused by Al in Cd determination was minimized by using 10 mu L of a 10% v/v H2SO4 solution in all measurements. Aqueous standard solutions were used for calibration and the limits of detection and quantification obtained were 7.3 and 24 pg mg(-1) for Cd, 0.13 and 0.45 ng mg(-1) for Cr, 0.07 and 0.23 mu g mg(-1) for Fe and 0.42 and 1.4 mu g mg(-1) for Al, respectively. The concentration values for Cd, Cr, Fe and Al obtained from the soil certified reference material (CRM) Montana Soil I (NIST SRM 2710a) analysis were in agreement with the reported ones. The precision of the measurements, expressed as the relative standard deviation, was better than 10%. Six soil samples from a vineyard field were investigated and the results are in accordance with the Brazilian legislation.
引用
收藏
页码:1269 / 1277
页数:9
相关论文
共 49 条
  • [31] ELIMINATION OF INTERFERENCES IN ELECTROTHERMAL-ATOMIZATION ATOMIC-ABSORPTION SPECTROMETRY OF CADMIUM
    OHTA, K
    AOKI, W
    MIZUNO, T
    [J]. TALANTA, 1988, 35 (11) : 831 - 836
  • [32] Development and recovery of iron deficiency by iron resupply to roots or leaves of strawberry plants
    Pestana, Maribela
    Correia, Pedro Jose
    Saavedra, Teresa
    Gama, Florinda
    Abadia, Anunciacion
    de Varennes, Amarilis
    [J]. PLANT PHYSIOLOGY AND BIOCHEMISTRY, 2012, 53 : 1 - 5
  • [33] A glance into aluminum toxicity and resistance in plants
    Poschenrieder, Charlotte
    Gunse, Benet
    Corrales, Isabel
    Barcelo, Juan
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2008, 400 (1-3) : 356 - 368
  • [34] Evaluation of Brazilian and Venezuelan Crude Oil Samples by Means of the Simultaneous Determination of Ni and V as Their Total and Non-volatile Fractions Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Quadros, Daiane P. C.
    Chaves, Eduardo S.
    Lepri, Fabio G.
    Borges, Daniel L. G.
    Welz, Bernhard
    Becker-Ross, Helmut
    Curtius, Adilson J.
    [J]. ENERGY & FUELS, 2010, 24 (11) : 5907 - 5911
  • [35] A dried urine spot test to simultaneously monitor Mo and Ti levels using solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry
    Rello, L.
    Lapena, A. C.
    Aramendia, M.
    Belarra, M. A.
    Resano, M.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 81 : 11 - 19
  • [36] Progress in the determination of metalloids and non-metals by means of high-resolution continuum source atomic or molecular absorption spectrometry. A critical review
    Resano, M.
    Florez, M. R.
    Garcia-Ruiz, E.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (9-10) : 2239 - 2259
  • [37] High-resolution continuum source atomic absorption spectrometry for the simultaneous or sequential monitoring of multiple lines. A critical review of current possibilities
    Resano, M.
    Florez, M. R.
    Garcia-Ruiz, E.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 88 : 85 - 97
  • [38] High-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of solid samples and complex materials: a tutorial review
    Resano, Martin
    Aramendia, Maite
    Belarra, Miguel A.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (12) : 2229 - 2250
  • [39] Simultaneous determination of Co, Fe, Ni and Pb in carbon nanotubes by means of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry
    Resano, Martin
    Bolea-Fernandez, Eduardo
    Mozas, Engracia
    Florez, Maria R.
    Grinberg, Patricia
    Sturgeon, Ralph E.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (05) : 657 - 665
  • [40] Fate of hazardous elements in agricultural soils surrounding a coal power plant complex from Santa Catarina (Brazil)
    Rodriguez-Iruretagoiena, Azibar
    Fdez-Ortiz de Vallejuelo, Silvia
    Gredilla, Ainara
    Ramos, Claudete G.
    Oliveira, Marcos L. S.
    Arana, Gorka
    de Diego, Alberto
    Manuel Madariaga, Juan
    Silva, Luis F. O.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 508 : 374 - 382