A comparison of two-dimensional and three-dimensional measurements of wear in a laboratory investigation

被引:33
作者
Rodriguez, Jose M. [1 ]
Bartlett, David W. [1 ]
机构
[1] Kings Coll London, Inst Dent, Restorat Grp, London SE1 9RT, England
关键词
Erosion; Abrasion; Two-dimensional; Three-dimensional; Surface matching; Profilometers; IN-VITRO; TOOTHBRUSH ABRASION; SURFACE-ROUGHNESS; ERODED ENAMEL; SITU;
D O I
10.1016/j.dental.2010.07.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The aim of this research was to compare two-dimensional (2D) and three-dimensional (3D) tooth measuring techniques after subjecting enamel samples to tooth wear in vitro on an erosionabrasion model. Method. 80 polished mid-coronal enamel sections were subjected to 10 wear cycles. Each cycle consisted of remineralization for 2h in artificial saliva, followed by 10min immersion in one of four acidic fruit drinks or distilled water and finally toothbrush abrasion with a non-fluoridated tooth paste. The resulting wear scars were measured using 2D and 3D techniques using surface matching software. Results. The 2D step heights measurements from the exposure to the four acidic drinks showed no statistically significant differences (median wear range=22.432.5 mu m) between them (p=0.99) but there were differences with distilled water (median wear=10.0 mu m) (p=0.01). The 3D measurements showed that two drinks produced more wear compared to the others and water when the whole surface and volume exposed to wear was accounted for (p=0.01). Significance. The difference in data from the two techniques showed that 3D measurements gave a more accurate assessment of the impact of the wear regime.
引用
收藏
页码:E221 / E225
页数:5
相关论文
共 14 条
[11]   Toothbrush abrasion, simulated tongue friction and attrition of eroded bovine enamel in vitro [J].
Vieira, A. ;
Overweg, E. ;
Ruben, J. L. ;
Huysmans, M. C. D. N. J. M. .
JOURNAL OF DENTISTRY, 2006, 34 (05) :336-342
[12]   Brushing abrasion of eroded bovine enamel pretreated with topical fluorides [J].
Vieira, A. ;
Lugtenborg, M. ;
Ruben, J. L. ;
Huysmans, M. C. D. N. J. M. .
CARIES RESEARCH, 2006, 40 (03) :224-230
[13]   Inhibition of erosive wear by fluoride varnish [J].
Vieira, A. ;
Jager, D. H. J. ;
Ruben, J. L. ;
Huysmans, M. C. D. N. J. M. .
CARIES RESEARCH, 2007, 41 (01) :61-67
[14]   Development of low erosive carbonated fruit drinks 2. Evaluation of an experimental carbonated blackcurrant drink compared to a conventional carbonated drink [J].
West, NX ;
Hughes, JA ;
Parker, DM ;
Moohan, M ;
Addy, M .
JOURNAL OF DENTISTRY, 2003, 31 (05) :361-365