Transcatheter Self-Expandable Valve Implantation for Aortic Stenosis in Small Aortic Annuli The TAVI-SMALL Registry

被引:72
作者
Regazzoli, Damiano [1 ]
Chiarito, Mauro [1 ,2 ]
Cannata, Francesco [1 ,2 ]
Pagnesi, Matteo [3 ]
Miura, Mizuki [4 ]
Ziviello, Francesca [5 ]
Picci, Andrea [6 ]
Reifart, Joerg [7 ]
De Marco, Federico [8 ]
Bedogni, Francesco [8 ]
Adamo, Marianna [9 ,10 ]
Curello, Salvatore [9 ,10 ]
Teles, Rui [11 ]
Taramasso, Maurizio [4 ]
Barbanti, Marco [6 ]
Tamburino, Corrado [6 ]
Stefanini, Giulio G. [1 ,2 ]
Mangieri, Antonio [3 ,12 ]
Giannini, Francesco [3 ,12 ]
Pagnotta, Paolo A. [1 ]
Maisano, Francesco [4 ]
Kim, Won-Keun [7 ]
Van Mieghem, Nicolas M. [5 ]
Colombo, Antonio [3 ,12 ]
Reimers, Bernhard [1 ]
Latib, Azeem [3 ,13 ]
机构
[1] Humanitas Res Hosp, Cardio Ctr, Via Manzoni 56, I-20089 Milan, Italy
[2] Humanitas Univ, Dept Biomed Sci, Milan, Italy
[3] Ist Sci San Raffaele, Intervent Cardiol Unit, Milan, Italy
[4] Univ Zurich, Zurich Univ Hosp, Heart Ctr, Zurich, Switzerland
[5] Erasmus MC, Thoraxctr, Dept Cardiol, Rotterdam, Netherlands
[6] Univ Catania, Ctr Alte Specialita & Trapianti, Policlin Vittorio Emanuele, Cardiol, Catania, Italy
[7] Kerckhoff Heart & Lung Ctr, Dept Cardiol & Cardiac Surg, Bad Nauheim, Germany
[8] IRCCS Policlin San Donato, Dept Cardiol, Milan, Italy
[9] Civil Hosp, Brescia, Italy
[10] Univ Brescia, Brescia, Italy
[11] Hosp Santa Cruz, Ctr Hosp Lisboa Ocidental, Lisbon, Portugal
[12] Maria Cecilia Hosp, GVM Care & Res, Ravenna, Italy
[13] Montefiore Med Ctr, Div Cardiol, New York, NY USA
关键词
self-expandable valves; small annuli; TAVR; PROSTHESIS-PATIENT MISMATCH; HIGH-RISK PATIENTS; EVOLUT PRO; REPLACEMENT; IMPACT; OUTCOMES; SIZE; DEFINITIONS; DEVICES; TRIAL;
D O I
10.1016/j.jcin.2019.08.041
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to evaluate and compare the outcomes of transcatheter self-expandable prostheses in patients with small annuli. BACKGROUND Transcatheter aortic heart valves appear to have better performance than surgical valves in terms of prosthesis-patient mismatch, especially in patients with aortic stenosis with small aortic annuli. METHODS TAVI-SMALL (International Multicenter Registry to Evaluate the Performance of Self-Expandable Valves in Small Aortic Annuli) is a retrospective registry of patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area < 400 mm(2) on computed tomography) treated with transcatheter self-expandable valves (n = 859; Evolut R, n = 397; Evolut PRO, n = 84; ACURATE, n = 201; Portico, n = 177). Primary endpoints were postprocedural mean aortic gradient, indexed effective orifice area, and rate of severe prosthesis-patient mismatch. RESULTS Pre-discharge gradients were consistently low in every group, with a slight benefit with the Evolut R (8.1 mm Hg; 95% confidence interval [CI]: 7.7 to 8.5 mm Hg) and Evolut PRO (6.9 mm Hg; 95% CI: 6.3 to 7.6 mm Hg) compared with the ACURATE (9.6 mm Hg; 95% CI: 8.9 to 10.2 mm Hg) and Portico (8.9 mm Hg; 95% CI: 8.2 to 9.6 mm Hg) groups (p < 0.001). Mean indexed effective orifice area was 1.04 cm(2)/m(2) (95% CI: 1.01 to 1.08 cm(2)/m(2)) with a trend toward lower values with the Portico. No significant differences were reported in terms of severe prosthesis-patient mismatch (overall rate 9.4%; p = 0.134), permanent pacemaker implantation (15.6%), and periprocedural and 1-year adverse events. Pre-discharge more than mild paravalvular leaks were significantly more common with the Portico (19.2%) and less common with the Evolut PRO (3.6%) compared with the Evolut R (11.8%) and ACURATE (9%) groups. CONCLUSIONS Transcatheter self-expandable valves showed optimal clinical and echocardiographic results in patients with small aortic annuli, although supra-annular functioning transcatheter heart valves seemed to slightly outperform intra-annular functioning ones. The role of transcatheter aortic valve replacement with self-expandable valves for the treatment of aortic stenosis in patients with small annuli needs to be confirmed in larger trials. (C) 2020 by the American College of Cardiology Foundation.
引用
收藏
页码:196 / 206
页数:11
相关论文
共 36 条
[1]   Bioprosthetic Valve Performance After Transcatheter Aortic Valve Replacement With Self-Expanding Versus Balloon-Expandable Valves in Large Versus Small Aortic Valve Annuli Insights From the CHOICE Trial and the CHOICE-Extend Registry [J].
Abdelghani, Mohammad ;
Mankerious, Nader ;
Allali, Abdelhakim ;
Landt, Martin ;
Kaur, Jatinderjit ;
Sulimov, Dmitriy S. ;
Merten, Constanze ;
Sachse, Susanne ;
Mehilli, Julinda ;
Neumann, Franz-Josef ;
Frerker, Christian ;
Kurz, Thomas ;
El-Mawardy, Mohamed ;
Richardt, Gert ;
Abdel-Wahab, Mohamed .
JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (24) :2507-2518
[2]   Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[3]   Predictors of paravalvular aortic regurgitation following self-expanding Medtronic CoreValve implantation: The role of annulus size, degree of calcification, and balloon size during pre-implantation valvuloplasty and implant depth [J].
Ali, O. F. ;
Schultz, C. ;
Jabbour, A. ;
Rubens, M. ;
Mittal, T. ;
Mohiaddin, R. ;
Davies, S. ;
Di Mario, C. ;
Van der Boon, R. ;
Ahmad, A. S. ;
Amrani, M. ;
Moat, N. ;
De Jaegere, P. P. T. ;
Dalby, M. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 179 :539-545
[4]   A systematic review on the safety of second-generation transcatheter aortic valves [J].
Athappan, Ganesh ;
Gajulapalli, Rama D. ;
Tuzcu, Murat E. ;
Svensson, Lars G. ;
Kapadia, Samir R. .
EUROINTERVENTION, 2016, 11 (09) :1034-1043
[5]   Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve Replacement [J].
Barbanti, Marco ;
Yang, Tae-Hyun ;
Cabau, Josep Rodes ;
Tamburino, Corrado ;
Wood, David A. ;
Jilaihawi, Hasan ;
Blanke, Phillip ;
Makkar, Raj R. ;
Latib, Azeem ;
Colombo, Antonio ;
Tarantini, Giuseppe ;
Raju, Rekha ;
Binder, Ronald K. ;
Nguyen, Giang ;
Freeman, Melanie ;
Ribeiro, Henrique B. ;
Kapadia, Samir ;
Min, James ;
Feuchtner, Gudrun ;
Gurtvich, Ronen ;
Alqoofi, Faisal ;
Pelletier, Marc ;
Ussia, Gian Paolo ;
Napodano, Massimo ;
de Brito, Fabio Sandoli ;
Kodali, Susheel ;
Norgaard, Bjarne L. ;
Hansson, Nicolaj C. ;
Pache, Gregor ;
Canovas, Sergio J. ;
Zhang, Hongbin ;
Leon, Martin B. ;
Webb, John G. ;
Leipsic, Jonathon .
CIRCULATION, 2013, 128 (03) :244-253
[6]   Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis [J].
Clavel, Marie-Annick ;
Webb, John G. ;
Pibarot, Philippe ;
Altwegg, Lukas ;
Dumont, Eric ;
Thompson, Chris ;
De Larochelliere, Robert ;
Doyle, Daniel ;
Masson, Jean-Bernard ;
Bergeron, Sebastien ;
Bertrand, Olivier F. ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) :1883-1891
[7]   Impact of Annular Size on Outcomes After Surgical or Transcatheter Aortic Valve Replacement [J].
Deeb, G. Michael ;
Chetcuti, Stanley J. ;
Yakubov, Steven J. ;
Patel, Himanshu J. ;
Grossman, P. Michael ;
Kleiman, Neal S. ;
Heiser, John ;
Merhi, William ;
Zorn, George L., III ;
Tadros, Peter N. ;
Petrossian, George ;
Robinson, Newell ;
Mumtaz, Mubashir ;
Gleason, Thomas G. ;
Huang, Jian ;
Conte, John V. ;
Popma, Jeffrey J. ;
Reardon, Michael J. .
ANNALS OF THORACIC SURGERY, 2018, 105 (04) :1129-1136
[8]   Self-expanding Portico Valve Versus Balloon-expandable SAPIEN XT Valve in Patients With Small Aortic Annuli: Comparison of Hemodynamic Performance [J].
Del Trigo, Maria ;
Dahou, Abdellaziz ;
Webb, John G. ;
Dvir, Danny ;
Puri, Rishi ;
Altisent, Omar Abdul-Jawad ;
Campelo-Parada, Francisco ;
Thompson, Chris ;
Leipsic, Jonathon ;
Stub, Dion ;
DeLarochelliere, Robert ;
Paradis, Jean-Michel ;
Dumont, Eric ;
Doyle, Daniel ;
Mohammadi, Siamak ;
Pasian, Sergio ;
Cote, Melanie ;
Pibarot, Philippe ;
Rodes-Cabau, Josep .
REVISTA ESPANOLA DE CARDIOLOGIA, 2016, 69 (05) :501-508
[9]   Aortic Stenosis and Small Aortic Annulus Clinical Challenges and Current Therapeutic Alternatives [J].
Freitas-Ferraz, Afonso B. ;
Tirado-Conte, Gabriela ;
Dagenais, Francois ;
Ruel, Marc ;
Al-Atassi, Talal ;
Dumont, Eric ;
Mohammadi, Siamak ;
Bernier, Mathieu ;
Pibarot, Philippe ;
Rodes-Cabau, Josep .
CIRCULATION, 2019, 139 (23) :2685-2702
[10]   The impact of prosthesispatient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years [J].
Head, Stuart J. ;
Mokhles, Mostafa M. ;
Osnabrugge, Ruben L. J. ;
Pibarot, Philippe ;
Mack, Michael J. ;
Takkenberg, Johanna J. M. ;
Bogers, Ad J. J. C. ;
Kappetein, Arie Pieter .
EUROPEAN HEART JOURNAL, 2012, 33 (12) :1518-1529