On-line preconcentration of mercury by sorption on an anion-exchange resin loaded with 1,5-bis[(2-pyridpl)-3-sulphophenyl methylene] thiocarbonohydrazide and determination by cold-vapour inductively coupled plasma atomic emission

被引:0
作者
Rudner, PC [1 ]
de Torres, AG [1 ]
Pavon, JMC [1 ]
Rojas, FS [1 ]
机构
[1] Univ Malaga, Fac Sci, Dept Analyt Chem, E-29071 Malaga, Spain
关键词
mercury; preconcentration; ion-exchange; inductively coupled plasma atomic emission spectrometry;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
1,5-Bis[(2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex) has been used for the on-line preconcentration of mercury from biological samples and waters prior to its determination by inductively coupled plasma atomic emission spectroscopy. The metal was eluted from the column using a solution of 2 M HNO3 and mixed on-line with SnCl2. The optimum experimental conditions were evaluated for the continuous preconcentration of Hg, the direct generation of mercury vapour and the final determination of this element by ICP-AES. The enrichment, together with low blank levels of the optimized procedure, allow the simple determination of this toxic element at concentrations down to a few nanograms per milliliter. The proposed method has a linear calibration range 5-1000 ng ml(-1) of mercury, with a detection limit of 4 ng ml(-1) (S/N = 3) and a sampling rate of 40 h(-1), investigated with a 9 ml sample volume. The precision of the method (evaluated as the relative standard deviation obtained after analyzing ten series of ten replicates) was +/- 3.6% at the 10 ng ml(-1) level of Hg(II) and +/- 1.3% at the 100 ng ml(-1) level. The accuracy of the method was examined by the analysis of certified reference materials. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1095 / 1105
页数:11
相关论文
共 24 条
[1]   DETERMINATION OF TRACE-ELEMENTS IN ANALYTICAL-REAGENT GRADE SODIUM-SALTS BY ATOMIC-ABSORPTION SPECTROMETRY AND INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY AFTER PRECONCENTRATION BY COLUMN SOLID-PHASE EXTRACTION [J].
ALEXANDROVA, A ;
ARPADJAN, S .
ANALYST, 1993, 118 (10) :1309-1312
[2]   Sorption of arsenic, bismuth, mercury, antimony, selenium and tin on dithiocarbamate loaded polyurethane foam as a preconcentration method for their determination in water samples by simultaneous inductively coupled plasma atomic emission spectrometry and electrothermal atomic absorption spectrometry [J].
Arpadjan, S ;
Vuchkova, L ;
Kostadinova, E .
ANALYST, 1997, 122 (03) :243-246
[3]   DETERMINATION OF TRACE-METALS IN REFERENCE WATER STANDARDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH ONLINE PRECONCENTRATION [J].
BEAUCHEMIN, D ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1857-1862
[4]   PRECONCENTRATION OF TRACE-METALS FROM SEA-WATER WITH THE CHELATING RESIN CHELAMINE [J].
BLAIN, S ;
APPRIOU, P ;
HANDEL, H .
ANALYTICA CHIMICA ACTA, 1993, 272 (01) :91-97
[5]   CELLULOSE TETPA - A CHELATING COLLECTOR DESIGNED FOR MULTIELEMENT PRECONCENTRATION IN FLOW SYSTEMS [J].
BURBA, P ;
ROCHA, JC ;
SCHULTE, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (04) :414-419
[6]   Determination of mercury in urine by ET-AAS using complexation with dithizone and extraction with cyclohexane [J].
Burrini, C ;
Cagnini, A .
TALANTA, 1997, 44 (07) :1219-1223
[7]   ONLINE ANALYTE PRECONCENTRATION WITH ATOMIC SPECTROMETRIC DETECTION [J].
EBDON, L ;
FISHER, AS ;
HILL, SJ ;
WORSFOLD, PJ .
JOURNAL OF AUTOMATIC CHEMISTRY, 1991, 13 (06) :281-286
[8]  
Fang Z., 1995, FLOW INJECTION ATOMI
[9]  
GREENWAY GM, 1993, ANAL PROC, V30, P438